The XM120 moisture analyzer meets the highest international quality standards. Precisa has developed an instrument which not only provides a high degree of precision, but also offers an outstanding array of additional options. XM120 will fit perfectly into your IT environment and has integrated connections to external PC’s and equipment.
Generous memory capacity, optimum control for measuring processes and state-of-the-art, user-friendly high-end weighing technology are its most impressive features. XM120 works according to the tried and tested infrared drying method, which is distinguished by a wide thermal radiation spectrum. This means that even heavy samples can be analysed accurately.
The XM60 moisture analyzer is the low-volume instrument for customers with low sample volumes and quantities. It is robust, perfectly accurate and simple to operate. Thanks to the high thermal values, it delivers quick and accurate results. Irrespective of your analysis criteria, the widest range of analysis options are at your disposal.
The XM66 delivers rapid moisture results for sewage and waste water treatment plants. The increased weighing range of 310g enables both the use of heavier tare vessels and greater specimen quantities. The moisture analyzer XM66 offers the option to store four weighing results which make it possible to calculate the ash residue after ashing of the specimen has been completed externally.
|
|
|
Sartorius moisture analysis and systems for water content analysis deliver convincing performance thanks to their exceptionally fast measurement results and exceptional reliability. They offer all the features required for use in fields of application relevant to GLP, GMP and cGMP.
|
|
|
|
|
|
The MS-70, MX-50, MF-50 and the ML-50 are moisture analyzers that utilize the heating and drying method, which compares the weight of a sample before and after heating and drying. Compared with Karl Fischer analyzers, the MS/MX/MF/ML analyzers are much easier to operate and require a shorter time for measurements. At the same time, they maintain very high repeatability thanks to the incorporation of A&D¡'s Super Hybrid Sensor (SHS) as the weighing sensor.
The Windows Communication Tools, WinCT-Moisture, is provided as standard for the MS and MX (optional for MF and ML). With the RsFig, the MS/MX/MF/ML can display a graph on a PC showing changes in the moisture rate while performing measurements. Moreover, with RsTemp, it is possible to determine the most suitable heating conditions for a given sample in a very short time. Specifically, RsTemp automatically changes the heat applied based on set increments and interval times within a range of 30°C-200°C. Given changes in the moisture rate over time, it can determine the most suitable heating temperature.
Another unique feature is that the MS/MX/MF/ML come standard with Sodium Tartrate Dihydrate. Sodium Tartrate Dihydrate is a chemical material that has a stable moisture content of approx. 15.66%, and is therefore ideal to check for accuracy in order to maintain the reference value of the analyzer.
The moisture content resolution of the MS, MX, MF and the ML is 0.001%, 0.01%, 0.05% and 0.1% respectively. The MS-70 is the leading model and is capable of measurements as precise as those done by a Karl Fischer moisture analyzer.
Please see the Users Handbook for the MS/MX/MF/ML for further details.
|
|
|
AMETEK's trace moisture analyzers use our unique quartz-crystal microbalance (QCM) technology or phosphorous pentoxide (P2O5) technology to provide accurate and fast moisture measurements in either ultra high purity semiconductor or industrial process gas streams. The analyzers are available in a variety of rack-mount, weatherproof, and explosion proof packages for monitoring ppmv or ppbv concentrations of moisture.
|
|
|
The IM series is an on-line multi IR wavelength analyzer utilizing the infrared absorption technology for measuring product constituent and/or thickness. Signal processing capabilities are built into the Compact All-In-One detector unit for easy installation and operation. A maximum of 99 calibration curves can be stored into the detector memory for numerous measurement applications. The detector can be used by itself or connected to a PC/plant control system, as both analog and digital outputs are provided. A remote setting display unit, connectable upto 9 detector units, can be used to setup various detector functions and also displays measured values.
|
|
The QMA2030 is a high-precision, fast responding, laboratory analyzer with automatic calibration, used for trace moisture measurement in high purity industrial gases. The process moisture analyzer is designed to give highly reliable, fast and accurate measurement of moisture content in many industrial pure gases. Using quartz crystal microbalance technology, the QMA2030 combines automatic calibration, using an internal wet reference source, with a touch screen control panel to provide easy operation.
The large LCD display allows live measurement data and system information to always be on view but the QMA 2030 also has a data logging capability that allows trend data to be downloaded to an external USB storage device. On-screen alarms can be set at user defined levels. Alarm contacts, and a 4-20mA analogue output are provided for connection to external monitoring systems.
|
|
|
|
|
|
The optimal hardware structure for varying applications is achieved by combining various standard mechanical and electronic modules. The measured values are available on two freely configurable and scaleable analogue outputs and on the serial RS232 interface.
Two freely configurable optional alarm outputs can be set by software. The measured data and the corresponding MIN/MAX values can be viewed on the optional LCD display. By selecting a suitable housing version the EE29/EE31 series can be used for the entire range of humidity measurement applications:
Model A: for wall mounting
Model B: for duct mounting
Model D: with remote sensing probe for measurements in the range of -40...180°C
Model E: with remote sensing probe for pressure tight applications between 0,01...15 bar
Model F: with rear cable outlet for wall mounting in clean room applications
Technical data
Measuring range: 0-100% RH; -40...180 °C
Outputs: 0-5V, 0-10V, 4-20mA, 0-20mA
Accuracy: +/-2% RH; +/-0.2 °C
Supply: 24V AC/DC
|
|
... for measuring the moisture content within a split second in a production run in progress thanks to the use of microwave resonance technology.
– Moisture analysis in less than 1 second
– Complete process monitoring
– Results independent of the color and surface structure of a sample
– Non-destructive measurements
– At-line measurements also possible
|
|
|
|
|
|
Powered by patented pulse mode, ion chamber technology in conjunction with a 500 mCi (18.5 GBq) source, the Thermo Scientific MOLA ensures repeatability of ±0.2%. In situations where a smaller source size is acceptable and/or required, the MOLA-LS features a 100 mCi source (3.7 GBq) to ensure repeatability of ±0.47%. Both models optimize blast furnace performance by accurately determining the moisture content in metallurgical grade coke
and/or iron ore pellets.
Based on Thermo Scientific patented pulse mode, ion chamber technology, the MOLA and MOLA-LS allow for excellent stability and repeatability over a wide temperature range without the need for high voltages or temperature stabilization of the circuitry. The signal from the detector is sent to a Thermo Scientific 1400S transmitter where the calculations and density compensation (external input from density gauge) are performed.
Like all Thermo Scientific nuclear gauges, the MOLA and MOLA-LS are easy-to-install and service. With no component exceeding 45 pounds, installation is greatly simplified. The streamlined design also allows for rapid diagnostics and servicing of the unit.
|
|
|
As the new Moisture Analyser for all purposes, the IR-35 offers a great performance especially matched to the daily needs in a laboratory. Its easy operational concept provides a large and clearly arranged display - that gives all important information at a glance, as well as an easy menue navigation - that directs the user with the help of easy to understand symbols from taring the sample pan to the beginning of the analysis in just three steps. Thanks to the fully self-controlled determination of the endpoint, no programming of a shutoff criteria is necessary. The moisture determination is monitored continously and the analysis is stopped once no further weight loss is detected.
|
|
Back-lit LCD graphic display with digit height 20 mm
2 halogen quartz glass heaters 500 W each
10 sample plates included
The last value measured remains on the display unt it is replaced by a new measurement
Application table. Various examples in the user manual
Balance contains memory for automatic sequence of 99 complete drying processes. Per memory location 12 free characters
Weighing in help to a defined target value [g] with adjustable tolerance range 1% - 25% of target value
User guidance step by step in the display. Selectable languages: German, English, Spanish
PC keyboard can be connected
|
|
|
|
|
|
Utilizing an Aluminum Oxide sensor 600 times more sensitive than conventional sensors
The 8800 series uses field proven aluminum oxide (Al2O3) sensing technology to accurately detect trace moisture on either a continuous or spot checking basis.
All Al2O3 sensors share the same basic operating principle: the capacitance measured between the sensor's aluminum core and gold film deposited on the oxide layer varies with the water content. However, the Series 8800 moisture sensor employs unique Hyper Thin Film (HTF) technology, which offers three major structural improvements in Al2O3 sensor design.
Versatile Design Options
The Series 8800 Single Point Trace Moisture Analyzers are provided in four compact, reliable designs with the ability to detect moisture from -100°C to ambient dewpoint levels of +20°C on either a continuous or spot checking basis.
- 8800A – Flush Mount DIN enclosure with connections made via a pluggable screw terminal block
- 8800B – Wall Mount N4X (IP65) enclosure with connections made 3 bottom watertight fittings
- 8800P – Portable battery operated design available in the Standard Version, I/O Version, and I/S Version (I/S version suitable for hazardous areas)
- 8800T – Low-cost, loop powered 4-20mA transmitter design with built-in LCD display
|
|
MIDAC's V-Series Moisture Analyzers provide unprecedented capability for detecting moisture and other impurities in corrosive gases. V-Series systems are the only complete, turnkey systems to give you all these features and capabilities:
- detection to less than 10ppb of H2O in many corrosive matrices, including Ammonia
- detection to 1.0 ppb in HCl
- complete immunity to the effects of atmospheric background moisture
- extremely fast response and equilibration times
- the ability to analyze multiple compounds in addition to moisture
- customized low volume sample cells electro-polished to eliminate moisture retention
- low internal power dissipation for durability under extended vacuum operation
- sensitive thermo-electrically cooled InAs detector
- short set-up time and easy transportability
- customized dedicated analytical and process software
- superior corrosion-resistant materials for extended service life
|
|
Designed to quickly, effectively and affordably measure moisture content, the Ohaus MB Series Moisture Analyzers incorporate state-of-the-art halogen heating with precision weighing technology to give a fast and accurate method for moisture content determination.
Perfect for applications in the pharmaceutical, chemical and research industries; versatile and rugged enough for continuous operation in food and beverage, quality control, environmental and many other applications.
|
|
Process Hygrometer Hygrophil® H 4230
Particularly suitable for cases where the air to be measured contains oil vapours, dust, water soluble gases, solvents, acids and aggressive chemicals.
Long-term stable psychrometer
Measurement range 0...100°C dewpoint
Profibus DP
Analogue outputs
System solution including gas withdrawal sensor, heated gas pipeline und measurement device
|
|
The METTLER TOLEDO family of moisture analyzers provides fast, precise and reliable moisture determination. Our solutions cover industries as diverse as pharmaceutical requiring compliance with regulations, plastics with the need for highest resolution or the food industry requiring robust and simple-to-use instruments for routine testing on the factory floor.
For more information, please click on the models listed below. To get support or a quote, please choose the appropriate button.
|
|
Designed to quickly, effectively and affordably measure moisture content, the Ohaus MB Series Moisture Analyzers incorporate state-of-the-art halogen heating with precision weighing technology to give a fast and accurate method for moisture content determination.
Perfect for applications in the pharmaceutical, chemical and research industries; versatile and rugged enough for continuous operation in food and beverage, quality control, environmental and many other applications.
|
|
|
|
|
|
The moisture measuring system IR 3000 consists of a non-contact working measuring head and a menu-driven interface for calibration and programming of the moisture measuring system.
The menu-driven interface is installed near to the measuring head and used as an external display near to the measuring position.
This allows reading of the measured moisture values at the sampling devices, for laboratory purposes.
With an Ethernet network or serial connection, measured values will be transferred from the menu-driven interface to a visualisation PC in the control room or to a process control system. Here, the central evaluation and display of all connected measuring systems will take place.
To achieve accurate measurement, a continuous flow of material is required. For operational areas, where a continuous material flow is not guaranteed, special sampling devices should be used. During this process, the material falls into an opening by the sampling device. Once measurement of a sample is complete, it is removed by compressed air so that the sampling device refills with material and the next measurement can take place.
|
|
|
The Spectra-QuadTM provides real-time information on moisture and other critical product parameters by monitoring product content. With the Spectra-Quad, you can control product quality and enhance process efficiency, which will improve your bottom line.
|
|
|
|
|
|
Speedy Moisture Tester for foundries and powders
The Standard Speedy 2000 series of moisture testers combines time proven dependability of the pressure test procedure with the convenience of an electric balance.
Moisture measurements are obtained by following a simple test procedure:
Prepare and weigh the material sample using the electronic balance.
Place the sample in the Speedy vessel.
Add the reagent to the recess in the Speedy cap and seal the vessel.
Shake the Speedy to mix the reagent with the sample.
Read the moisture content directly from the integral gauge.
Technical Information:
Standard Speedy vessel fitted with calibrated pressure gauge, electronic balance, heavy duty carry case with fitted foam inserts, cleaning brush and cloth, measuring scoop and instructions.
Nominal gross weight: 12.1lb (5.5Kg)
Nominal gross dimensions: 20 x 15 x 8" (510 x 380 x 200mm)
For 0 - 10% range: 12g
For 0 - 20% range: 6g
Maximum sample size: 0.4" (10mm)
Moisture measurement range expressed as a percentage of the wet weight of the sample: Model F-S2000C: 0 - 10%, Model F-S2000D:0 -20%
|
|
|
|
|
|
SONO-MOVE: The new Sensor for direct measurements in moved materials
Precise moisture measurements – directly on conveyors and in silos, containers and hoppers.
The novel probe head consists of Wolfram-Carbide and a very wear-resistant ceramic in order to warrant for a long life-span of the probe. Thanks to the Wedge-shaped structure and at only 12mm thickness of the probe the flow of the material on the conveyor belt is only slightly affected.
In case of abrasion, a recalibration is not necessary.
The TRIME technology ensures safe measurements even under difficult conditions, e.g. if the bulk material contains conductive elements with up to 12dS/m pore water conductivity. The radar-based evaluation of the conductance (RbC – Radar based Conductance) enables to establish the mineral content in the measured material and consequently ensures an improved quality control.
The intelligent pre-processing of the measurement values featuring smooth mean value accumulation, adjustable filters, and up to 15 calibration curves for the calibration which is already conducted in the sensor itself. Usually, external evaluation devices are not required.
A RS485 interface enables network operation of the sensor. It already contains a data bus protocol for the connection of several SONO sensors.
The connection of the sensor to industrial buses such as Profibus, Ethernet, etc. is possible via optional external modules (available upon
request).
|
|
Grain and product moisture measurement.
Direct, representative, fast and precise with the most modern TDR technology.
* direct measurement of moisture in the material
* continuous data logging concerning the moisture level
* optimum and precise process control throughout all cycles
* lower product value losses as the result of over- or under-drying
* savings in heating costs and power consumption
TRIME®-GW monitors the water content and optimizes
your process control.
With TRIME®-GW you can directly control the product moisture even during the drying process without taking any samples! Problematic, indirect measuring techniques, such as via extracted air or temperature, are now things of the past. TRIME®-GW directly measures the water content of the product being dried regardless of the grade, temperature or mineral content of the goods being measured. That way, you can continuously monitor the water content of the goods being dried and optimize the process control.
|
|
|
|
|
|
Hydro-Mix VI for Moisture Measurement in Mixers
Tough, digital, flush mounted sensor for measurement of moisture in wet and dry materials during the mixing cycle, in chutes and mixers.
The Hydro-Mix VI is a rugged, flush mounted microwave moisture measurement sensor for mixers and other process control environments. Designed by Hydronix to be installed in the turbulent environment of a mixer, the Hydro-Mix features integral signal processing and is easily connected to any control system. The sensor reads at 25 times per second which enables rapid detection in moisture content in the process, including the determination of homogeneity.
Typically used to measure moisture in concrete mixing, the Hydro-Mix VI is also used successfully in other industries where it can be installed in a mixer, for example, grain processing and animal feed. The Hydro-Mix is fitted into the floor of a mixer or screw conveyor and takes measurements as the material flows over the ceramic head during processing.
Remote configuration, calibration, diagnostics and software upgrades can easily be undertaken using Hydronix Hydro-Com software. This allows direct integration with any control system without the requirement of any other interface unit. Combined with on-board functionality such as signal processing, smoothing and averaging the Hydro-Mix VI is simple to integrate.
|
|
|
|
|
|
The tailor made solution for measuring bore hole humidity in
hardened concrete.
The James Instruments Humitest System allows the concrete practitioner to monitor and ensure that a new structure is dry enough to proceed with the next phase of construction. This is especially critical for concrete structures requiring a coating, carpeting or similar floor or covering treatment. Installing such treatments before the concrete is sufficiently dry will typically cause expensive failures in the covering treatment. The only accurate way to ensure that the concrete is sufficiently dry enough to safely avoid expensive re-work is via a bore hole humidity test system, such as the Humitest System™.
The system works by first boring a hole into the concrete and inserting a plastic tube in the hole. The plastic tube is then plugged and the system is set to stabilize and the humidity to reach equilibrium. The probe is then inserted into the plastic tube, left to stabilize for a short period of time, and then a reading is taken.
The sleeve is recommended to give readings at various depths in the concrete. As concrete moisture distribution is typically very uneven it is recommended to take readings at different depths depending on the structures exposure.
|
|
|
|
|
|
SONO-MIX: The new Concrete Sensor – Measures directly in the Mixer.
Highest accuracy at the measurement of moisture and material composition in fresh concrete – directly in the mixer using state-of-the-art RbC technology.
Higher safety at the production of fresh concrete due to the precise measurement of the moisture as well as the radar-based conductance (RbC – Radar based Conductance) up to 50dS/m. RbC enables conclusions regarding further parameters of the material recipe such as the cement content and the slope of
fresh concrete with the effect of a more reliable quality control and higher cost-effectiveness because recipe errors are prevented.
The novel and very robust sensor head (15 mm thick) consists of wear-resistant hardened steel with a rectangular ceramic window. It is fastened with 4 screws and can easily be exchanged. In case of abrasion, a recalibration is not necessary.
The intelligent pre-processing of the measurement values with smooth mean value accumulation, adjustable filters, and the storage of up to 15 calibration curves for the calibration which is already conducted in the sensor itself. Usually, external evaluation devices are not required.
Two variably adjustable analogue outputs 0(4)...20mA enable the easy connection to any control system.
A RS485 interface enables the network operation of the sensor. It already contains a data bus protocol for the connection of several SONO sensors. The connection of the sensor to industrial buses such as Profibus, Ethernet, etc. is possible via optional external modules (available upon request).
|
|