- Electricity - Electronics >
- Switch and Relay >
- Multipole disconnect switch
Multipole disconnect switches
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Primary current: 32 A - 1,600 A
... ELCB is not chosen to use in a special characteristic of the load, the special breaker is needed. On creating an isolation switch (DSN) by omitting the overcurrent tripping device of a MCCB, it can be used as a switching ...
Primary current: 160 A
VAC: 690 V
... screw, clamp strap, Al-Cu clamp, extendable for V-terminal - optional • Padlocking and sealing of switch door cover - optional • Indicating switch for switch door position - optional • ...
Primary current: 30 A - 1,200 A
... products, these switches are also engineered to have the smallest footprint. The modular design allows placement of the handle anywhere amongst the poles. The fuse doors cannot open when the switch is ...
Primary current: 630 A
VAC: 690 V
MULTIVERT® NH 4P is the first vertical 4-pole switchable (3P + N) in-line fuse switch disconnector for busbar systems 185mm with an overall width of 100mm. It is the most inovative and cost-efficient ...
Primary current: 0 A - 1,250 A
VAC: 155 V - 690 V
The Fuserbloc from Socomec are manually operated with multi-polar fuse combination switches for industrial fuses of up to 1250 A. The unit make and break on load, and deliver safety isolation. It ...
SOCOMEC
Primary current: 32, 63, 100, 125 A
VAC: 230, 400 V
As the main switch in the combination of electrical terminal apparatus, GYH8 isolator is suitable for circuit of AC 50/60Hz, rated voltage 230V/400V, rated current up to 125A for isolating, it also can be used for infrequent ...
Primary current: 630 A - 6,300 A
VAC: 12 kV - 40.5 kV
VDC: 1,500 V - 3,000 V
... contact blades etc. Thoroughly clean the switches and actuator elements prior to putting into operation to remove dust and installation swarf and wipe all insulating parts with a clean dry cloth. The switches ...
Fritz Driescher & Söhne GmbH
VAC: 15 kV
DRIESCHER - indoor and outdoor earthing switches - 1-pole and 2-pole design - Indoor and outdoor applications - Nominal voltage from 1,5 kV up to 25 kV
Fritz Driescher & Söhne GmbH
Primary current: 400, 63 A
VAC: 36, 24 kV
... the change offuses.DRIESCHER indoor transformer switch disconnectors M3007 can also be delivered with mounted earthing switch (below or above) as well as with auxiliaryswitches (up to 8 contacts) on switch ...
Fritz Driescher & Söhne GmbH
Primary current: 40, 25, 63 A
VDC: 600, 200, 1,000 V
Primary current: 20 A - 125 A
VAC: 400, 230 V
Primary current: 40 A
VAC: 800 V
Switch – disconnectors on-load available from 40A to 6300A in 3P – 3P+N & 4P versions (under request). Rated breaking current of up to 8 times the rated operational current, whit ability to establish ...
Telergon
Primary current: 63 A
VAC: 800 V
Switch – disconnectors on-load available from 40A to 6300A in 3P – 3P+N & 4P versions (under request). Rated breaking current of up to 8 times the rated operational current, whit ability to establish ...
Telergon
Primary current: 80 A
VAC: 800 V
Switch – disconnectors on-load available from 40A to 6300A in 3P – 3P+N & 4P versions (under request). Rated breaking current of up to 8 times the rated operational current, whit ability to establish ...
Telergon
Primary current: 40 A - 1,600 A
VAC: 500, 1,000, 690 V
... the current situation of the switch. And finally they can also check the engine whether the contact blades are noticeable if so, it means that the switch is at 0 point. And if the blades are not noticeable ...
Cefem Group
Primary current: 40 A - 800 A
VAC: 500 V - 1,000 V
... Sugar, Glass industries. The SAFEBLOC Satinless Steel circuit breaker and isolation switch boxes are installed in direct proximity to the machines and engines on industrial sites.
Cefem Group
Primary current: 40 A - 800 A
VAC: 1,000 V
VDC: 1,000 V
... operate the switch. If the contact (blades) are visible then the engine is switched OFF and is in 0 position as seen on the switch. On the contrary if the contacts (blades) are not seen then the switch ...
Cefem Group
Primary current: 2 A - 63 A
VAC: 400 V
VDC: max 220.0 V
Switches and push-buttons are components for switching consumers in industrial, commercial and private electrical installations, such as switch-disconnectors, impulse relays (remote switches) and main ...
Primary current: 32 A - 125 A
... this new product family solves the critical requirement to disconnect power so that operators and service technicians can work on the machine in complete safety. The new modular disconnectors cover a ...
Primary current: 16 A - 100 A
VAC: 690 V
VDC: 600 V
... - 40A switches) EN 60947-3 Low voltage switchgear and controlgear Part 3: switches disconnectors, switch-disconnectors and fuse-combination unit UL 508 Industrial control equipement
Primary current: 25 A - 160 A
VAC: 230, 400 V
... used as a main switch in low voltage distribution systems. It is easily to be assembled and works with the same series of compact circuit breakers together. · Only 18mm for 1P, 36mm for 2P, 54mm for 3P and 72mm for ...
WENZHOU RENA ELECTRIC CO.,LTD
Primary current: 25, 30, 40, 50, 63 A
VAC: 240, 415 V
... used as a main switch in low voltage distribution systems. It is easily to be assembled and works with the same series of compact circuit breakers together. · Only 18mm for 1P, 36mm for 2P, 54mm for 3P and 72mm for ...
WENZHOU RENA ELECTRIC CO.,LTD
Primary current: 25, 40 A
VAC: 240, 415 V
... circuit. It is used as a main switch in low voltage distribution systems. It is easily to be assembled and works with the same series of compact circuit breakers together. · Only 18mm for 2P and 36mm for 4P · Main ...
WENZHOU RENA ELECTRIC CO.,LTD
... indicated on both handle and switch. Door interlocking is provided by the handle.The design of the switch provides a direct connection on the switch terminals and is expandable with auxiliary ...
Primary current: 63 A - 630 A
3NJ6 switch disconnectors with fuses feature an integrated switching device with single or double interruption capacity. They are especially well-suited for applications where large numbers of cable runs for power distribution ...
Siemens Low-voltage – Power distribution
Primary current: 10 A - 630 A
VAC: 690 V
... the frequency converter Reliable load disconnect switch with positively opening main contacts Functional Description - R. STAHL's 8146/5-V11 series load disconnect switches can be used ...
Primary current: 32, 63, 80, 100, 125 A
VAC: 240, 415 V
VH12-125 series switch disconnection (hereinafter referred to as switch ) applies to power distribution and control circuits with AC 50Hz, rated current up to 125A,rated voltage up to 415V. It’s mainly ...
Alduti-Rupter® Switches S&C Alduti-Rupter Switches provide no-external-arc circuit interruption for underground distribution circuits. They are ideally suited for line switching, transformer switching, ...
Primary current: 100, 125, 32, 63, 250 A
VAC: 230, 400 V
A reliable and trusted main isolating switch disconnect is crucial for ensuring the safety of electricians and maintenance engineers working on your aplication. The IMO range of isolating switch ...
IMO Precision Controls Limited
Primary current: 20, 35, 63 A
VAC: 240, 415 V
UKF&UKW isolator is rigidly built to withstand more than just the vagaries of the weather, it is designed also for frequent switching even on severe load such as switching of motor loads or other highly inductive load. Suitable to be ...
Primary current: 40 A - 125 A
VAC: 230, 400 V
... loaded electrical circuits - As a main circuit breaker - Protection of heavy loaded electrical circuits Applications: - Industrial and administrative buildings Mounting: On a DIN rail Standards: ЕN60947-3
Elmark
Primary current: 40 A - 125 A
VAC: 500 V
... isolate a specific circuit for maintenance and help prevent any currents from passing through. The isolator, or main isolator switch, is typically comprised of one or two sets of electrical contacts mounted in a series. ...
Aswich Electrical Co., Ltd
Primary current: 32 A - 100 A
VAC: 230, 400 V
... The product meets the standards of GB14048.3 and IEC60947-3. • Disconnector Switch number of pôle: single pôle, two pôles, three pôles and four pôles; • The disconnector switch ...
Radin Electric Technology Co., lTD
Primary current: 40, 63, 80, 100 A
VAC: 750 V
Federal Elektrik
Primary current: 3 A - 32 A
VDC: 500, 600, 800, 1,000 V
... compliant with AS60947.3:2018 DC-PV2 and IEC60947. 1000V True DC for solar PV application IP66 1000V 32A true DC isolator switch BYH-32 is developed for Australia and worldwide solar installation. Be ...
Zhejiang Benyi Electrical Co.,ltd.
Primary current: 0 A - 300 A
VDC: 110, 23, 36, 72 V
LTRM disconnector is designed for applications up to 4 kV and are available with electric motor control (24, 36, 72, 110 VDC). Its compact dimensions make it particularly suitable for application up to 300 A where ...
Microelettrica
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining