Description:
The model H500 is an RGB Color Analyzer that can measure the amount of Red, Blue and Green as well as the Hue, Saturation and Luminance of items such as Paints, Plastics, Fabrics, or just about anything you might need to know the color of.
Features:
* Measure both RGB and HSL levels
* Easy to use relative (REL) feature allows the comparison of two color samples
* Easy to use
* Two year warranty
Applications:
* Check color levels of Plastics, Textiles, Paper, Paints and Leathers
* Quality control in production and manufacturing
* Comparisons of color samples against color standards
* Check reference color values of CRTs, LCD monitors and light lamps
|
|
For more than 10 years, the Konica Minolta CRT Colour Analyzer CA-100 has set the standards for white balancing and colour control on CRT monitors for computer and broadcast displays.
With the new CRT COLOUR ANALYZER CA-100Plus, Konica Minolta presents a new reference instrument with highly improved functions and accuracy to confirm its leadership in display measurement technology, while maintaining the ease of use, functionality and compatibility to the famous CA-100.
Measurement speed has been improved as well as the measuring range, which has been expanded for the low luminance range.
The CA-100Plus is characterised by its ease of use. The lightweight receptor head is simply held in front of the television or monitor and the measurement values appear immediately on the large display. A rubber lip on the receptor head minimises the effects of ambient light.
|
|
Product Features:
- Faster makeready - Scans the color bar of a typical press sheet in just 15 seconds
- Improved quality control - Displays real-time measurement results and pinpoints problem areas
- Expanded results reporting - Offers extensive data collection and network capabilities to improve information sharing and integration
- Faster ROI - Saves time and reduces material waste and makes your company more profitable and more competitive
|
|
The OP1100 Discontinuity Analyzer is an off-the-shelf fiber optic test System that automatically captures, displays and logs short optical power interruptions and spikes in the accordance with EIA/TIA-FOTP-32A
This test solution provides a method for testing a broad variety of passive or active fiber optic components for susceptibility to discontinuities (single dropout, transient output or transmittance fluctuations) during application of an external stimulus, such as temperature, vibration or physical shock.
|
|
|
The CA-210 LCD Color Analyzer is Konica Minolta's "next generation" color analyzer designed to measure color luminance, gamma characteristic and flicker on various types of Flat Panel Displays including LCD and EL. Faster than previous generation analyzers, the CA-210's measurement of luminance and chromaticity at up to 20 times/second makes it ideal in high production environments. (AND it can simultaneously measure up to five points on the screen. ) The CA-210's special optical design limits acceptance angle to within ± 2.5 degrees, thus eliminating the influence of the LCD's viewing angle dependency. Matrix calibration allows for high measurement of LCD displays that provide colors through additive mixing of three monochrome colors (R,G,B). A new low luminance capability enables measurements as low as 0.1cd/m2
|
|
The module PW0049 is a stand-alone measuring device which is conceived for the absolute measurement of self-illuminating objects.
Its function is to reproduce the CIE 1931 2° CMF's as precisely as possible. The resulting Tristimulus measuring values X, Y, Z form the basis of most of the common color spaces used today.
|
|
|
|
|
|
The BaySpec’s CWDM Series Optical Spectrum Analyzer (OSA) is an embedded, integrated monitor that delivers precise measurement and powerful processing capabilities to coarse wavelength division multiplexing (CWDM) applications compliant with the ITU-T G.695 standard.
Coarse Wave Division Multiplexing (CWDM) combines up to 18 wavelengths onto a single fiber. CWDM technology uses ITU standard 20nm spacing between the wavelengths, from 1310nm to 1610nm. High reliability (GR-1209/1221 qualified) is achieved through a rugged mechanical design with no moving parts. Periodic calibration is not required. Input/Output (I/O) is provided through a dual port RAM interface accessed through ADD/DAT bus direct connection or serial (RS232 or USB) communications.
The CWDM OSA Series employs a highly efficient Volume Phase Grating (VPG) as the spectral dispersion element and an ultra sensitive InGaAs array detector as the detection element, thereby providing high-speed parallel processing and continuous spectrum measurements. As an input, the device uses a tapped signal from the main data transmission link through a single mode fiber, then collimating it with a micro lens. The signal is spectrally dispersed with the VPGâ, and the diffracted field is focused onto an InGaAs array detector. The control electronics read out the processed digital signal to extract required information. Both the raw data and the processed data are available to the host through the supported interfaces.
|
|
The ultimate platform for network experts. Combines physical, optical, transport and datacom testing in a single box. Perform simultaneous acquisitions and fast data post-processing, and benefit from a scalable range of test applications and field-interchangeable modules.
Key Features and Benefits
Five configurations (two-slot, four-slot, seven-slot, eight-slot and bus protector), providing maximum flexibility for long-haul, metro, DWDM, high-fiber-count, Ethernet, SONET/SDH or DSn/PDH test applications
Pentium-powered, with up to 512 MB memory
Easy-to-read, high-resolution 12.1 inch TFT screen
Windows® operating system
Simultaneous acquisitions and fast data post-processing
|
|
|
|
|
|
AQ6319
Powered by constant technological innovation, Ando presents its new flagship, the AQ6319 optical Spectrum Analyzer. The new AQ6319 packs the power of cutting-edge technologies with many years of research. It holds the best optical performance on the market and provides customers with a user-friendly interface for faster and more accurate measurement. In fact, the AQ6319 raises the standards in the optical testing industry.
With an unprecedented wavelength accuracy of ±10 pm (1520-1580 nm), the AQ6319 OSA has become an outstanding instrument in both general and specialized R&D labs for high accuracy wavelength measurement. Ando keeps the "free-space" design between the incident beam and the monochrometer; this proven technology which is inherited from the world-renowned AQ6317 series OSAs offers much greater facility for researchers using specialty fibers, especially with large core diameters. The new AQ6319 offers a much faster sweep speed than the previous models. It also features a LAN connection for faster and easier data transfer, as well as remote control capabilities. In addition, many new analysis functions have been included.
|
|
An all-parameter evaluation instrument providing a comprehensive characterization of modules and subsystems of up to 70 meters of device length.
* All-parameter analysis (loss, dispersion, PMD, etc)
* Total system integration
* High resolution S-C-L band capability
* Real-time measurements
* Integrated, easy to use interface
* Time domain viewing
* Complete polarization response
* Look inside devices - time domain viewing
* Automatic internal calibration
|
|
Spectrographs are optical emission monitors that integrate sophisticated embedded processors and software designed to provide intelligent instrument control, data acquisition and endpoint interface capabilities.
Spectrograph SD1024F™ – High Performance
Features and Benefits
- Provides robust endpoint determination
- SpectraView™ software provides:
Variety of algorithms
Tool integration via Ethernet, RS232, and DI/O
- Use for endpoint detection, fault detection, and process diagnostics
- 200–800nm range
|
|
|
Q8384 is a high-grade optical spectrum analyzer (Advantest) with a 4-pass monochromator and extremely low polarization dependance. Thanks to a special method used, a value of ±0.05 dB can be guaranteed, the typical value is as low as 0.02 dB. The narrowest resolution bandwidth and the broad dynamic range make the Q8384 an ideal measuring instrument in the DWDM technology for closest channel spacing. A special measurement function allows the automatic determination of erbium-doped fiber amplifiers (EDFA) parameters; these are e.g. noise figure, gain and spontaneous emission by simple comparison of the signal at the amplifier input with the signal at the amplifier output.
|
|
|
An all-parameter evaluation instrument providing a comprehensive characterization of modules and subsystems of up to 70 meters of device length.
|
|
|
|
|
|
RXA 156/170
The RXA 156 and RXA 170 modules are equipped with a micro flow cell and an integrated Peltier thermostat ensuring accurate and automatic temperature control. Fast and non-destructive measurements, requiring only small sample volume, yield to refractive index (RI) and RI-derived results. Both RXA types can be used as a module in measuring systems.
All the advantages of modular design
* Combination with a DMA 4100/4500/5000, DSA 5000 or Soft Drink Analyzer 2 to a measuring system
* DMA, DSA or Soft Drink Analyzer 2 serve as the control and evaluation unit of the system
* The instruments can be used separately if required
* For pasty or expensive samples, manual filling of the refractometer is possible
* Simple adjustment of both instruments using air and water in one procedure
* Automatic filling and cleaning of both instruments with an optional sample changer
One measuring cycle, two (three) sample parameters
* Save time by simultaneously determining the density (and sound velocity) and refractive index
* Fast and reliable results
Reliable measuring methods
* Established U-tube method for measuring density
* Highly accurate measurement of the angle of total reflection for determining the refractive index
|
|
|
|
|
|
The PFO3372 Multiwave Fiber Optic Photometer solution is effective in UV(ultraviolet), VIS (visible), NIR (near infrared) applications where:
- Sample Stream is highly toxic
- Corrosive products are analyzed
- Streams are at high temperature
- Streams are at high pressure
- The Sample is at high vacuum
- The Sample needs to remain sanitary
- Fast response time is required
- Sample is at a high pressure
ABB process photometers provide continuous on-line measurement of gas or liquid components, in simple or complex process streams, for process control, product quality assurance, safety, catalyst protections and area monitoring.
The PFO3372 incorporates the use of fiber optic sampling accessories for added measurement capability.
Moisture applications such as water in acds, water in methanol, water in hydrocarbons or hydrocarbons in water are good candidates for the fiber optic option. Applications that require a fast response time, such as monitoring the Lower Explosive Limit (LEL) for hydrocarbons in air, should also be considered.
|
|
| ... products without technical information |
| |
|
|