Melles Griot offers a wide variety of power and energy meters. Our integrated, broadband power meter uses thermopile technology, has a flat response from 200 nm to 20 µm, and can measure output power from 10 µW to 2 W. Our modular power meter system is based around two control units and a plethora of calibrated, interchangeable, thermopile, semiconductor, and pyroelectric detector heads capable of measuring cw and pulsed output power ranging from a few picowatts to 50 watts.
|
|
|
|
|
|
Features
-NIST traceable calibration
-Measures power and wavelength with ILX Power/Waveheads
-Integrating sphere-based power measurements
-Measurement heads cover a wide wavelength range from 350 to 1700nm
-Power measurement up to 10W
-Free-space and fiber measurement heads
-Easy test system integration with standard GPIB interface
The OMM-6810B is the only power meter capable of measuring the optical power and wavelength of semiconductor lasers including short wavelength lasers, high power pumps, and fiber lasers. A variety of measurement heads cover wavelength ranges from 350 to 1700nm for power only or power and wavelength measurement.
In addition to precision power and wavelength measurements, the OMM-6810B is loaded with standard features such as log/linear display modes, auto ranging, user calibration, and reference measurement capability. All of these features plus an analog output and IEEE-standard GPIB interface combine to make this instrument a cost-effective laser diode development or production test tool.
|
|
|
Bi-Directional Insertion Loss Test System or multi-mode or single mode with either singlemode or multimode internal source.
|
|
|
Multichannel optical power meter with internal individual power meter modules for concurrent data acquisition with higher data acquisition rate.
|
|
Fastest Monitor in our Product Range!
The S-LINK-2 is Gentec-EO’s first Multi-Channel, PC-Based, Power and Energy Monitor. Faster than any other monitor in our product range, with 10 kHz of REAL TIME data transfer for each channel, with no missing points. That’s right, you get every single pulse transferred directly into your PC, at 10 000 times per second!
Features
# 2 Channels
# Reads Pyroelectric Metallic Absorbers up to 6 kHz
# Real Time data Transfer of 10 kHz/Channel, No Missing Points or Averaging!
# Communication Through USB or Ethernet
# True measurement of RMS & PTP Stability, Repetition Rate and # of Pulses with Pyroelectric Detectors
# External Trigger
# Compact Design
# Competitive Price
|
|
The SOLO 2 is our next generation SOLO monitor; making it our most complete handheld power and energy meter. You will find all the useful functions you liked on the SOLO PE, with improved performances and speed. Take a look at the main features of the SOLO 2:
# Reads both power and energy detectors
# Fast 200 Hz data transfer rate
# Reads fast energy detectors up to 3 kHz
# Large 78 x 58 mm LCD screen with backlight
# Full statistical functions in real time
# Unequalled 225 000 points data storage
# Fast prediction algorithm for accelerated power measurements
|
|
The XLE4 – eXtreme Low Energy Detector
eXtreme Low Energy measurement: this is what the XLE4 stands for. From nJ’s to mJ’s, the XLE4 offers accurate NIST measurements in all conditions. It is a nice complement to our series of QE energy detectors to read even lower energies.
Low Noise Level
The XLE4 low noise equivalent energy of 30 nJ with an amplifier or 150 nJ with a SOLO sets it apart from the competition. This pyroelectric detector thus extends in the nJ’s the measurement range of QE series joulemeters. Its high sensitivity of 1100 V/J makes it ideal for measurement in noisy laser environments.
kHz Repetition Rate
The metallic coating of the XLE4 makes it an excellent choice for pulsed lasers up to 2000 Hz. It can detect pulses of duration up to 5 µs. Moreover, it can be used with many different types of lasers due to its broad spectral range.
|
|
|
The UP12E family was designed for portability. It is an excellent choice for field service or small beam OEM applications. The low profile stand alone detector measures a few mW to 10 W and to 20 W with its heatsink. Water cooling takes it to 70 W of continuous power. That is great for embedding in machines and immunity from environmental fluctuations. Great performance in a package as little as 14 mm deep!
|
|
|
Gentec-EO offers OEM customers the highest flexibility so that you make no compromise. Whether you want a different housing, a specific sensitivity or another output connector, we have a solution for you. We will adjust existing models or design a whole new detector to best meet your needs.
|
|
|
Dynasonics TFX Ultra ultrasonic flow and energy meter clamps onto the outside of pipes and do not contact the internal liquid. Available in stand alone flow meter or as an energy flow meter used in conjunction with dual clamp-on RTDs measuring energy usage. Available in integral and remote mount systems, both in a rugged, aluminum enclosure. Reduced material costs, installation time and maintenance costs make this the ideal flow meter for nearly all liquid applications.
|
|
The Heat Calculator Option of FLEXIM's non invasive FLUXUS ADM flow meter allows the easy determination of the energy flow in a system.
With temperature measurements made at the inlet and at the outlet of a system as well as flow measurement at the outlet , FLUXUS calculates the Heat Flow or energy usage within that system. All this is done with temperature and flow measurement devices mounted on the outside of a pipe.
FLUXUS will display the actual heat flow through the system, and if needed, totalize the heat flow in order to obtain the heat quantity.
The values can easily be transmitted to a PC for display and analysis. The data obtained can be used for energy flow balancing or it can be transmitted to a process control system.
|
|
Static compact energy meter using ultrasonic technology
highly accurate recording of all billing data in local and district heating and cooling systems
|
|
APPLICATION
Horizontal installation
For hot water up to 120 °C
Model 414 with carbide bearing
Overall and connection dimensions to DIN ISO 4064
DN15-50mm-PN16
DN 20 - 40 mm - with flange, PN 16 and PN 40 available
Operating pressure to DIN 2401
Max.24V,(SELV),0.2A
Protection class IP 65
Volume measuring component for measuring heat tor billing hot water consumption
Facility tor remote transmission of flow rates
Cable length: 3 m {0.25mm2)
|
|
APPLICATION
□ Fully electronic compact heat meter or compact cooling & heat meter with impeller scanning for recording energy and volume data.
□ Highly accurate recording of all billing data in a heating circuit or a cooling & heating circuit at medium temperatures up to 90 °C.
□ Horizontal and vertical installation, also overhead for Model 447/450.
|
|
| ... products without technical information |
| |
The TK81 Tunable Filter/Vibration Meter is a low-cost, portable handheld instrument for basic vibration measurements. It can display vibration in both unfiltered (overall) and filtered modes. It accepts inputs from displacement, velocity, and acceleration transducers, but does not provide power for them.
Its filtering capability is particularly useful for diagnosing vibration problems occurring at particular frequencies on all types of machinery. The TK81 is powered by a single 9V transistor battery.
|
|
HFM 436 Lambda - Heat flow meter
With the HFM 436 Lambda, samples measuring 30 cm x 30 cm or 60 cm x 60 cm and of variable thicknesses ranging from a few millimeters to 10 (20) cm are tested between two heat flux sensors in fixed or adjustable temperature gradients. After a few minutes for the system to reach equilibrium, the built-in PC or external computer determines the thermal conductivity and thermal resistance of the sample.
Automatic plate movement and determination of the sample thickness simplify test preparation.
All test parameters as well as the calibration data are stored in the PC and documented.
Determination of thermal conductivity with the HFM 436 Lambda meets the industry standards ASTM C 518, ISO 8301, JIS A 1412, DIN EN 12939, DIN EN 13163 and DIN EN 12667.
|
|
200136 Seal-Leak Detection (SLD) Transducer
The 200136 SLD transducer incorporates highly reliable proximity probe technology observing a moving diaphragm to detect static pressure changes on the non-pressurized end of single or double seals or between tandem or dual seals. Changes in pressure indicate failing seals. The transducer is specifically designed for use with our 200135 TIM as part of a Trendmaster® Pro system for continuous monitoring of process pumps handling toxic or flammable materials in the chemical and hydrocarbon processing industries
|
|
|
|