|
|
Verify the opacity of containers with on-line, high-speed, accurate and reliable measurements. The OPAX-1000™ combines proven sensor technology with innovative hardware to provide an easy-to-use system to measure light transmission in a wide variety of applications.
Many products require packaging designed to protect the contents from the damaging effects of light. Establishing pass/fail criteria for minimum opacity of these containers and providing on-line measurement eliminates defects and allows real-time quality control of these processes. The OPAX-1000™ provides a reliable solution, allowing you to monitor every container, and identify and remove containers with low opacity. |
|
The control of surface microroughness on a hard disk is critical for manufacturers. The TMS 2000-RC from Schmitt Measurement Systems more than meets this challenge and several versions of this device are available. Schmittt revolutionized disk manufacturing technology by providing the fastest, most accurate, non-contact texture measurement system in the world - laser technology of the future available today.
The TMS 2000-RC provides fast, accurate, repeatable microroughness measurements for computer hard disk manufacturers. The system quadruples production throughput, compared to other testing devices. |
|
| Measurements of diameters without contact. The haloes present in a Petri dish can be sized with this device only by pushing the reset button in one edge of the spot and moving the holder to the opposite edge of the halo. The display shows the diameter with an accuracy of 0.1 mm. |
|
| The Power Wizard™ power meter from Synrad offers a unique solution to the measurement of laser power and serves as a service tool to ensure maximum laser performance at any time. Designed to measure power levels from 1-250W, the PW-250 provides accurate measurement of average laser power, which is displayed on an easy-to-read LCD screen. |
|
| Coherent offers the broadest line of laser power meters and laser energy meters available anywhere. In addition, as the world's leading producer of laser systems, we thoroughly understand the practical requirements and challenges of using laser measurement tools. This puts Coherent in a unique position to configure a laser measurement system that provides the right combination of performance, features and cost for your particular needs. The modularity of the Coherent system also ensures that your investment will be protected as your needs evolve or change. |
|
Features
-NIST traceable calibration
-Measures power and wavelength with ILX Power/Waveheads
-Integrating sphere-based power measurements
-Measurement heads cover a wide wavelength range from 350 to 1700nm
-Power measurement up to 10W
-Free-space and fiber measurement heads
-Easy test system integration with standard GPIB interface |
|
| The OP710 offers an economical approach for optical power measurement applications where multiple channels are needed. Unlike other systems this instrument is built up with individual power meters allowing for unparalleled simultaneous data acquisition over all channels. |
|
OAI's Model 306 UV Power Meter is a highly reliable direct reading Instrument designed expressly for measuring light intensity at the wafer plane of mask aligners, UV curing light sources, and any other UV light source. Special probes enable measurement of light in the visible range. Calibration accuracy is within +/- 3% and is NIST traceable. Measurement repeatability is within /- 1%. It is auto ranging from 0.1 to 1999 mw/cm2 full scale and has 1% linearity in this range. This instrument features meter to meter matchability.
|
|
High-accuracy measurements of two-dimensional color distribution
Konica Minolta Sensing introduce the 2D Color Analyzer CA-2000, an instrument for high-accuracy two-dimensional measurements of the colour distribution and uniformity of all kinds of light-emitting devices, including various display devices such as plasma displays, LCD displays, etc. and automotive components such as car navigation systems or instrument panels.
|
|
CA-100Plus has higher speed, higher performance, and lower cost than its predecessor, the CA-100, which has been a standard of the CRT manufacturing industry since 1990.
Engineered for both bench top and production floor use, and fully compatible with data from the earlier CA-100 model, the new Minolta CA-100Plus CRT Color Analyzer provides higher speed (maximum 20 times/second), as well as Luminance and Chromaticity measurements with a new low luminance capability to 0.05cd/m2, making it suitable for measurement of gamma characteristic and contrast adjustment. The CA-100Plus is equipped with 100 memory channels. Up to 5 sensing probes can be used for simultaneous multiple point measurement. A USB interface connects the CA-100Plus to a computer, and the NEW Software Development Kit makes it easy to use Visual Basic or Visual C to automate measurement and adjustment factors.
|
|
The latest generation of Konica Minolta lux meters, the T-10, replaces the globally successful models of the T-1 series. The small, easy-to-use handheld meters are capable of measuring intermittent light sources, can be connected to each other to form multi-point units, and are easily controlled with a PC. They have an extremely large measuring range of 0.01 to 299,000 1x with automatic range switching, and a large, backlight LCD. And all of that with Konica Minolta's renowned high level of precision in a small, compact design.
Areas of application
Konica Minolta lux meters are used whenever brightness and the quantity of ambient light must be measured. Even the measurement of average values and illumination is possible. Examples of their use include the measurement of workplace and street illumination, the production of lamps, as well as architectural, forestry, and agricultural applications. Deployment in hard-to-reach spaces and under water are possible, just as the metering of very large surfaces and projectors (ANSI lumens) by serial connection of several receptor heads. Metered values can also be visualized graphically and even fully automated by using the PC software. |
|
Konica Minolta, a global leader in optical technology, manufactures a complete line of light meters and spot meters to measure luminance, illuminance, chromaticity values, color temperature in Kelvin, and UV radiation.
Konica Minolta light meters are hand-held, battery operated, and lightweight. Several measure continuous and flickering light sources; others are capable of non-contact measurement of light sources or reflective surfaces. Konica Minolta's light and spot meters measure in lux and foot-candles, or foot lamberts and CD/m² |
|
Digital Light meter ( DLM 530 , DLM 531)
Digital Light meter :
ModelFDLM 530 Lux meter (Range : From 20 to 200,000 Lux )
Model: DLM 531 Lux/ Footcandle Meter
(Range : 20 Lux,200 lux, 2000 lux, 20,000 Lux; 20fc, 200fc, 2000fc, 20,000fc)
MDOEL : DLM 536 Datalogging light meter
DLM 530 Features:
For Simple One Hand Operation
Accurate Visible Compensation Filter ff1 is Used.
CIE (ă):ff1<2%,<3%,<5%,<8%,v(ă)Match
Cosine Response:ff2<2%
Range : From 20 to 200,000 Lux
Analog Output Standard
Valox Housing to Withstand Accidental Drops
Digital and Analog Output Function
Highly accurate ff1 Compensation and Diffuser ff2<2%
MAX/Data Hold Function
Backlit LCD Display
DLM531 Features:
For Simple One Hand Operation
Accurate Visible Compensation Filter ff1 is Used.
CIE (ă):ff1<2%,<3%,<5%,<8%,v(ă)Match
Cosine Response:ff2<2%
Range : 20 Lux,200 lux, 2000 lux, 20,000 Lux ; 20fc, 200fc, 2000fc, 20,000fc
Analog Output Standard (output impedance 500 ohm)
Valox Housing to Withstand Accidental Drops
Digital and Analog Output Function
Highly accurate ff1 Compensation and Diffuser ff2<2%
Peak Data Hold Function
Backlit LCD Display
High Accuracy : }3%rdg+10dgts
3 1/2 digit LCD display with a maximum reading of 1999
Automatic Zero
MODEL DLM 536
Spectrum of photo sensor meets C.I.E.
photopic curve V(l)
16000 Records Data logging capacity
RS-232 interface (software included)
Measurement of luminous intensity
(PC Software) |
|
The spot luminance meters LS-100 and LS-110, categorized in the upper range of the DIN quality class B, are among the best hand meters on the market. The SLR (single lens reflex) optical system allows precise targeting and ensures the viewfinder showing the exact area to be measured, even at very short distances. This makes even precise focussing very easy. In addition to the measurement field and the measurement environment, the viewfinder also shows the measured luminance value. The pistol grip makes handling of the unit very secure. We paid special attention to minimize flare and to give precise V(lambda) correlation (CIE relative photopic luminosity curve). With the help of a close-up lens, areas as small as 0.4mm diameter can be measured.
Areas of application
Light sources of all types can be measured with the LS, for example signal, traffic lights, airport lighting, lamps, LEDs, picture tubes, etc., simply anything that emits light. Now you can, for example, guarantee minimum brightness, exchange lamps that are too dark, create quality assurance in the production of lamps, or check indirectly illuminated objects like movie screens. |
|
LM-80 Digital Light Meter With Analog Output:
- 4 ranges from 0,1 Lux to 20.000 Lux
- Selection of Lux or fc (footcandle)
- Data and Peak Hold function
- Manual ranging
- Measuring rate of 2 times/sec
- Analog DC Voltage output to operate with a Chart Recorder or Data Logger
- incl. carrying case and battery |
|
This low cost light meter resolves down to 0.1 lux, making it appropriate for use in very low light applications.
The handbook gives details of conversion factors for different light wavelengths allowing more accurate measurements.
Peak hold & hold allow a maximum reading to be recorded or one particular result to be kept. Results can be shown in lux or foot candles.
LM90: 20 lux to 20k lux
(preferred for emergency lighting applications LM92: 200 lux to 200k lux
(more sensitive in higher ranges). |
|
The LM631 is a portable, easy-to-use, compact sized digital light meter designed for simple one hand operation with the measurement reading in lux or fc units. This value priced unit offers high resolution readings and adherence to published standards for human eye response to illuminance.
Designed for the Facility Engineer or Building Maintenance personnel who need to ensure indoor light and work area lighting requirements, compliance with safety regulations, security reasons to monitor building and security light levels. Anyone who wants to measure illumination levels. |
|
Unfors Light-O-Meter is a perfectly simple, multi-function pocket sized instrument for Quality Assurance of image workstation monitors, image intensifier monitors, film viewing boxes, ambient light, collimator light field, etc in radiology departments.
The Unfors Light-O-Meter state-of-the art detectors have a CIE spectral response and cosine characteristics.
- Simultaneous measurements of cd/m2 and lux
- Pocket sized
- Microprocessor controlled |
|
Features:
- Low cost highest precision.
- Measuring intensities of illumination in Lux or Footcandles.
- Measuring lights source includes all visible.
- Multi-function for Data hold, Max. and Zero adjustment.
- Cosine angular corrected. |
|
| Konica Minolta Chroma-Meter have a world-wide reputation for easy and fast colour difference measurement in a very wide field of applications. Especially in the Ingredients-, Food and Chemical industry, the ruggedness and ease of use have led to their reference status. The CR-400 series feature many enhanced functions compared to the previous series maintaining full data compatibility. |
|
CIELAB Color Checker PR0086-S
With the system CIELAB Color Checker PR0086-S concerns it a contactless on-line color measuring system, which is adjusted on a high absolute color accuracy.
Technical data:
Supply voltage 24V DC
Interface R-S 485
Absolute accuracy ~1,6 dE (on the average)
Relative accuracy smaller +-0,5 dE (between the systems)
Optimal work distance 70mm (CIELab)
Measuring surface 70mm with 70mm work distance
Measuring frequency ~10Hz
Lighting integrated LED´s
Temperature compensation 10 to 55 degrees
Measuring procedure difference measurement
WIN32-DLL
Expenditure CIELab, Chromaticity and tri stimulus by communication.
Dust shield air connection 2mm |
|
| ... products without technical information |
| |
|
|