Simply the best HARMONIC and FLICKER test system available today. HAR1000 does not require expensive and bulky AC sources, it uses a novel technique to provide active compensation of distortion on the national power mains.
Featuring dual analysers, the input and output signal are constantly monitored to ensure compliance. HAR1000 conforms to the latest standards but also allows testing to previous standard editions should that be required.
HAR1000 can be enhanced with the following accessories.
HAR-EXT1000, three phase system. Adds two further phases to the HAR1000. Simple connection without any hardware modifications mean this powerful extension can be added at any time to an existing single phase system.
HARCS Immunity software package can be added to both the single and three phase systems. It extends the system’s emission capability to include harmonic immunity according to IEC61000-4-13, voltage fluctuations according to IEC61000-4-14 and ripple on DC according to IEC61000-4-17.
Adding the EMC Partner PS3 programmable power source, allows testing to IEC61000-4-28 for frequency fluctuations.
|
|
CIR-e3 PORTABLE ENERGY AUDIT ANALYZER
Most portable analyzers in the market require highly complex parameter establishing processes and start-up procedures.
CIR-e3 has been designed to facilitate the configuration and execution of electrical parameter measurements and, as a consequence, the analysis of energy audit studies.
Applications:
•Energy audits in installations.
•Preventive control and maintenance of transformer substations.
•Subcontracting energy audits.
|
|
|
|
|
|
FDS-PDC Dielectric Response Analyzer
The most important aging indicator of transformers is the water content in the solid part of the insulation (paper, pressboard). An accurate knowledge about the actual moisture concentration is thus required in order to decide if further corrective action, such as on-site drying, is necessary.
OMICRON's DIRANA determines the moisture content in oil-paper insulations of power transformers, CT's and VT's, bushings and power cables by analyzing the dielectric response. The patented device combines the high frequency advantages of the FDS (Frequency Domain Spectroscopy) method in the upper frequency range with the test speed advantages of the PDC (Polarization Depolarization Current) method in the lower frequency range.
Applications
- Moisture assessment of any oil-paper-insulation, such as power transformers, current and voltage transformers, insulated cables and OIP bushings.
- Capacitance and dissipation factor measurements of power transformers as well as bushings, cables, generator and motor insulations
- Aging detection for bushings even at ambient temperature
|
|
|
|
|
|
As a response to the measurement requirements for any distribution and control board, CIRCUTOR has developed a new electrical power analyzer for three-phase systems: CVM-MINI.
Of course any equipment can measure the main parameters in electrical systems, but the smaller size of the three module, DIN analyser, combined with a large number of advantages, make the CVM-MINI the best option for measurement and energy control solutions:
-Capacity to process more than 213 electrical parameters.
-DIN rail mounting or panel mounting (72X72) using an adapter.
-RS485 communications with Modbus/RTU protocol.
-Easy to build into existing control systems.
-Programming, measurement, recording and control software.
-Universal power supply
CIRCUTOR has built into one single small piece of equipment, the performance of any instrument found on any distribution and control board (protection boards, motor and pump control, overload and earth leakage distribution boxes, etc.), in a size and price which will make any board, no matter how small, be incomplete without the presence of the CVM-MINI.
|
|
|
|
|
|
|
COMBI420 is an innovative meter designed to perform all safety test verifies on electrical installations in compliance to recently standards (VDE0100, BS7671 and so on, measure and save results of environmental parameters (illuminanance, temperature), leakage currents and active power, harmonics, power factor measurements on single phase systems. The meter it's very easy to use and have a wide number of internal features which are selectable by using the multilanguage menu. The instrument permits, moreover, to start principal measures by using a special remote prove (PR400 optional accessory) particular useful to perform tests in very quickly mode and the AUTO internal function to perform sequential measurements of Global Earth Resistance, test on RCDs' and Insulation directly on sockets of civil installations. A contextual help menu selectable by user it's available for each measurement function and permits a valid information during connection of meter to the installation. The newest electronic function selector give to the meter a extreme rugged structure for perfect using "on field". A wide internal memory permits the saving of any measurements and the transfer to PC by serial port with dedicated software it's possible. Each measure it's saved with all the sub-results and test parameters with up to two ID locators (selectable by user on meter) in order to reach the exact point where the measure was performed.
|
|
|
|
|
|
The UPM315 is a multifunction metering DIN96x96 device with advanced functionality features, suitable for electrical parameters measurement and power quality analysis.
Main features:
- DIN 96 & ANSI 4” Cutout for New or Retrofit Panels
- Highly Sofisticated Power Meter Providing Advanced Functionality Features
- Large Graphic LCD Display with Excellent Visibility
- Up to Two Plug-In Options
- THD Even, Odd and Individual FFT Harmonic Analysis up to 50th Order
- Power and Current Demand Calculation
- On-Board Memory up to 2MB
- Programmable Min/Max & Energy Data Logging
- Event and Alarm Recording, Waveform Capture, Waveform Display, Phasor Diagrams, Historical Trending, Time-of-Use and more....
The UPM3080 is a multifunction metering DIN144x144 device with advanced functionality features, suitable for electrical parameters measurement and power quality analysis.
Main features:
- Fully Bi-Directional Four Quadrant Readings
- Neutral Current Measurement
- Large Graphic LCD Display with Excellent Visibility
- Up to Two Plug-In Options
- Infrared Communication Port
- THD Even, Odd and Individual FFT Harmonic Analysis up to 50th Order
- Power and Current Demand Calculation
- On-Board Memory up to 2MB
- Programmable Min/Avg/Max and Energy Data Logging
- Event and Alarm Recording, Waveform Capture, Waveform Display, Phasor Diagrams, Historical Trending, Time-of-Use and more....
|
|
|
KHA1000 is a harmonic and flicker analyzer compliant with the latest versions of the relevant IEC/EN and JIS standards (as of January 2006) that is intended for testing single-phase, two-line equipment. Using this device alone, you can perform a series of processes involved in a compliance test - from setting test conditions and running the test to monitoring the test status in real time, judging test results against limit values, and outputting result reports - through simple operations without the use of any dedicated software. Also, a test system can be set up with ease by combining KHA1000 with an AC power supply (PCR-LA Series) and a line impedance network (LIN40MA-PCR-L).
|
|
The UPM6100 is a portable analyser suitable for electrical parameters measurement on single- and three-phase systems, as well as on direct current systems.
Main features:
- 4 MB Removable Memory Card for Data Logging
- Integrated Printer (Option)
- Large Graphic LCD Display with Excellent Visibility
- Graphic Representation of Voltage and Current Waveforms, Harmonic Spectrum and Phasor Diagrams
- FFT Harmonic Analysis up to 50th Order
- Sags and Swells Detection
- Power and Current Demand Calculation
- Compact and Rugged Case Carrying Accessories
- UL Listed Under UL61010B-1 and CAN/CSAC22.2 No.1010.1-92, File #E231725
- Dedalo Software Included
|
|
Our HypotULTRA III family is designed for automated test applications. They offer a full compliment of automation interfaces including Ethernet, RS-232, IEEE-488(GPIB) and more. Our fully automated products can also be controlled with Autoware®, our stand alone software. They are also compatible with the latest Labview® software drivers.
Our HypotMAX, 500 VA models are designed for automated test applications. They offer a full compliment of automation interfaces including RS-232, and IEEE-488(GPIB). Our fully automated products can also be controlled with Autoware®, our stand alone software, and are compatible with the latest Labview® software drivers.
Our HypotMAX, High Voltage models are designed for automated test applications. They offer a full compliment of automation interfaces including RS-232, and IEEE-488(GPIB). Our fully automated products can also be controlled with Autoware®, our stand alone software, and are compatible with the latest Labview® software drivers.
|
|
|
|
|
|
The MC 760 network analyzer is used for permanent analysis of electric voltage quality in compliance with the SIST EN 50160 standard. Records are stored in the internal memory for the period of the last 7 years. Moreover, more than 170,000 deviations of the measured quantities from the standard values are stored, which enables finding of eventual reasons for the problems on network. Optional limits and required quality in a monitored period can be defined for each monitored characteristic.
The meter measures and records the following characteristics:
Frequency deviations
Voltage deviations
Voltage clips
Voltage interruptions
Voltage unbalances
Over-voltages
Fast voltage changes
Flicker intensity
THD
Harmonics
Features:
Evaluation of the quality of electric voltage in compliance with SIST EN 50160
Measurements of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, ö, THD, MD, energy, energy price by tariffs, etc.)
Accuracy class 0.5 or 0.2 (on demand)
Harmonic analysis of phase, phase-to-phase voltages and currents up to the 63th harmonics
Recording up to 32 measured quantities and alarms in the internal memory (8 MB flash)
Measurements of 40 minimal and maximal values in different time periods
32 adjustable alarms
Wide frequency range from 16 Hz to 400 Hz
RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication
MODBUS and DNP3 communication protocol
Up to 4 inputs or outputs (analogue outputs, pulse outputs, alarm outputs, tariff inputs)
Universal or AC power supply
Automatic range of nominal current up to 5 A and nominal voltage up to 500 V
Multilingual support
User-friendly PC MiQen software
|
|
MCA Plus network analyzer is an electronic instrument which allows the measurement of 48 main parameters in the input network in real value and RMS value.
It is specially designed for easy installation and programming. It needs three voltage signals (RST) and current (I1, I2, I3).
MCA Plus is supplied with LCD screens backlighted for an easy reading at any lighting level. It offers optional communication module and has internal memory.
|
|
Designed for verification and maintenance departments in industrial or administrative buildings, the Qualistar C.A 8334 enables the user to obtain an instant picture of the main characteristics of electrical network quality.
Handy and very compact, this instrument also gives numerous calculated values and several processing functions in line with current standards: EN 50160, IEC 61000-4-15, IEC 61000-4-30, IEC 61000-4-7.
|
|
The MAVOWATT 50 energy and power disturbance analyzer is the professional tool for optimized mains quality. It records all relevant measured quantities for supply power, and allows for a detailed analysis of
disturbances. Its versatile concept makes it a true multi-talent.
The MAVOWATT 50 is capable of executing all measuring functions simultaneously, can be used in all types of electrical systems and is equipped with measuring and data interfaces for all practical applications, a
great variety of display modes and various memory functions.
|
|
The EN6100-3-2 standard deals with the limitation of harmonic currents injected into the public mains supply system. Meanwhile, the EN6100-3-3 standard addresses the limitation of voltage fluctuations and flicker in low-voltage supply systems for equipment with a rated current of over 16A. These two standards, which became a mandatory requirement in Europe in 2001, apply to electrical and electronic equipment that have an input current up to and including 16A per phase and that are intended to be connected to public low-voltage distribution systems, such as supply voltages nominally 230V AC or 415V AC 3 phase.
|
|
The HARMONICS-1000 is a flexible one-box test and measurement equipment for testing and measuring harmonics and flicker on power supply. Because of the new designed amplifier the weight and the price of the HARMONICS-1000 are low.
|
|
|
Portable network analyzer PNA 760 is used for field measuring of different electrical quantities. Using PNA 760 you can easily and quickly find out if electrical voltage complies with EN 50160 standard. It is equipped with numerous accessories for voltage, current measurement and data transfer through various interfaces.
|
|
|
|
|
|
In view of the growing number of factors with a disturbing influence on power systems and the ever increasing sensitivity of the devices and installations on the consumer side, simple monitoring criteria such as undervoltage or overcurrent are usually inadequate nowadays. Reliable logging of all the relevant events within the electrical power system calls for the constant observation of a wide variety of derived parameters such as harmonic content, system unbalance or interharmonics and the swift identification of the slightest deviation from the standard state.
In addition to providing pure monitoring functions, modern power system analysing equipment should be capable of logging in full the mode of operation and the interaction of all the component parts of a power supply system.
Only comprehensive and continuous monitoring of the entire power system enables all resources to be used purposively and effectively for the restoration of system operation should a disturbance occur.
In addition, the recorded data provides the planners of electrical installations and protection equipment with an invaluable basis for the extension and optimisation of primary and secondary equipment.
If you are not already convinced of the importance of using a modern power system monitor, you certainly will be as soon as you are confronted with the question of who is liable for system disturbances and who is responsible for meeting the costs involved.
|
|
Your VNA provides you with the most accurate measurements only if calibrated against known standards. Pasternack VNA Calibration Kits and Tools incorporate accurate, stable, and precise calibration standards designed for a broad range of vector network analyzers models, including Agilent and Anritsu products.
The 3.5mm Standard and N-Type Standard Calibration kits are designed for use with a broad range of vector network analyzers (VNAs) that utilize a Short-Open-Load calibration technique. With the kits you can make error-corrected measurements of devices supplied with either 3.5mm or SMA connectors from DC to 26.5 GHz, or from DC to 11 GHz for N-type connectors. The kits contain both Male (Plug) and Female (Jack) connector interfaces to perform full Two-Port error corrections.
FEATURES:
- Broad VNA Coverage, Including Agilent & Anritsu
- Open, Short, Fixed Broadband Load Configurations
- DC to 26.5 GHz
- In-Series Phase Matched Adapters Available
|
|
OMICRON's CT Analyzer is a unique lightweight electronic multifunctional instrument designed to meet the highest standards for performing excitation, ratio, polarity and winding resistance tests on current transformers (CTs) as well as burden-impedance measurement.
Applications
- Burden measurement
- CT Winding resistance measurement
- CT Excitation characteristic recording
- CT transient behavior measurement (IEC60044-6)
- CT ratio measurement with consideration of connected burden
- CT phase and polarity measurement
- Determination of accuracy limiting factor (ALF), instrument security factor (FS), secondary time constant (Ts), remanence factor (Kr), transient dimensioning factor (Ktd), knee point voltage/current, class, saturated and non saturated inductance
- Assessment according to defined standards: IEC60044-1, IEC60044-6, IEEE C57.13-1993
|
|