Our electrical testing instruments cover the widest range of electrical tests required by international safety standards.
Depending on the specificities of your test and your test bench, ATEQ engineers determine which of our wide range of electrical testers best suits your application.
|
|
The testing device 92-7G/-7M is concieved for the control via an external PC/PLC. Therefore display and operating devices were renounced. The modular design of the testing instrument permits an optimal adaptation to the individual requirements of the user. Uneeded functions or equipment are omitted. Together with the device ELABO offers an efficient software package.
HV
The high-voltage is produced primarily over an internal electronic HV-source with a high clock frequency and regulated within less 10 ms. Because of the internal source a low residual ripple < 3% (accordingto VDE 0432-1) can be realised, also for DC tests with high currents. The synchronisation can be carried out on an external signal, on the mains frequency or internal (free-running). An electronic voltage ramp mode (voltage ramp up and ramp down) allows for tests of electronic equipment, at which a non-destructive test can only be carried out if the test voltage is increased slowly or for test items with high self-capacitances. The integrated residual voltage measurement assures a safe discharge of thecapacitances of the test items.
Insulation resistance
Insulation resistance measurement with voltages from 500 V up to 8000 V DC at full HV-current are possible. The resistance measurement is carried out together with the high voltage test at the sametime.
PE resistance
Measuring of the PE resistance or the voltage drop at the protective earth conductor through fully electronicregulated programmable test current 10 ... 32 A at an AC voltage of 6 or 12 V.
|
|
EurotestXA is the top of the range installation safety tester with automated testing based on patent pending AUTO SEQUENCE®.
Because of the need to be efficient, fast and competitive but still reliable and concentrated on safety, all the technical content and innovations under AUTO SEQUENCE®, focus on taking care of the testing procedure itself. If you are after a high speed, safety, and reliable least-fuss testing instrument, look no further.
|
|
Hipot test to 6kVDC 10mA
Hipot test to 5kVAC 40mA
Ground Bond test to 42 Amps RMS
Insulation Resistance 50 to 1000V
Automated Remote Interface
|
|
Universal mobile
The test system is equipped with a universal tester. With this new developed unit you can also carry out high- voltage tests with AC or DC.
Furthermore you can also realize an insulation- and PE- resistance test. Moreover the test system can be expanded with a leakage current tester for the latest norms. The components are connected with a matrix and they are controlled with a special software package.
The slots are placed in a 19” / 12HE Rack. The whole test system is placed in a mobile. To adapt the test probes serves a connection box. With this box you can contact all kind of test probes.
At the back of the tester are high- voltage sockets. So you can realize a manual high- voltage test.
As an option the mobile is equipped with a PC.
|
|
|
SIRIUS 87 is a model to performing all safety tests according to VDE 0413 on electrical installations. Inside model are integrated new fundamental features: the possibility to perform Loop Impedance (P-P, P-N, P-PE) at high resolution (0.1mOhms) with use of IMP57 optional accessory. Thanks to its PC interface and powerful software you will create accurate documents qualifying your profession more and more.
|
|
|
SIRIUS89N is a complete model to perform all safety tests in compliance to VDE 0413, measure of values of environmental parameters (temperature/humidity, illuminance, sound level with optional probes), leakage current with optional clamp and to perform a network power quality of single phase in compliance to EN50160 guideline.RCDs which suddenly trip out, transformers which overheat, motors which burn out, voltage sags and surges which create problems, all these problems could be easily solved with SIRIUS89N. The meter permits to perform a Loop impedance measurement (P-P, P-N, P-PE) also with high resolution (0.1mOhms) with the use of IMP57 optional accessory and five predefined recording settings are integrated in order to to help the user on the most common situation which are present on the network quality (EN50160, Voltage Anomalies, Harmonics, Start-Up and Power & Energy). SIRIUS89N can perform current measurements up to 3000A AC also by using a flexible clamp type in order to perform measurements on big cables or bars also. Thanks to the PC interface and the powerful software you will create accurate documents qualifying your professionalism more and more.
|
|
Featuring
RS232, PCL & GPIB Control
AC Hipot to 5KV
DC hipot to 6KV
Insulation Resistance to 10GW
ARC Detection
Ground Continuity to .001W
|
|
| ... products without technical information |
| |
Application: The sensors are made by protective ceramic tube connecting with customized high temperature wires, small size but excellent in resisting water and shake, which can be used in many areas, including medical instrument, intelligent instrument, oven, also be suit for gas environments¡¯ high temperature measurement.
Sensitive element: Pt 100, Pt200, Pt 500 or Pt 1000 (single or double)
Tolerance: all conform to the requirements of IEC 751
Temperature range: -200¡æ--£«1200¡æ
Shell:
--diameter: ¦Õ3.00 mm, length: 15 mm
-- diameter: ¦Õ4.00 mm, length: 20 mm
-- diameter: ¦Õ5.00 mm, length: 25 mm
-- diameter: ¦Õ6.00 mm, length: 30 mm
Other types can be customized
Wires: 2, 3 and 4-wire or connector
-- length: can be customized
-- type: special glass fiber (max. temperature 1200¡æ)
Protective grade: all conform to the requirements of IP 54
Option:
-- Protective grade¡ªIpxx
-- Higher precision ( Glass A, DIN1/3£¬DIN1/10)
|
|
| ... products without technical information |
| |
|
|