Use the Smart Flow Meter for metering, monitoring or totalization of bulk material flows, or as a feeder in high rate applications.
|
|
The RFIK mechanical hydraulic tester provides the ideal solution for servicing and commissioning
hydraulic circuits on agricultural and other mobile machinery.
The kit comprises of a direct acting flow indicator with built in thermometer, a loading valve and a pressure gauge all built into a strong steel case with a removable lid.
The unit is self contained and requires no electrical power. The dials are clear and easy to read.
Installation is extremely simple and the test kit can be connected into either the pressure or return lines. The loading valve and pressure gauge allow a progressive build up of system pressure in complete safety.
The test kit provides the service engineer with quick, accurate and simple performance testing of pumps, motors, valves, cylinders and complete hydraulic
circuits.
Note: This unit is not designed for permanent installation.
|
|
Metal Magmeter Flow Sensor (Signet 2552)
Plastic Magmeter Flow Sensor (Signet 2551)
Flow Wet-Tap Valve (Signet 3519)
Metal Paddlewheel Flow Sensors (Signet 525, 2517, 2540)
Plastic Paddlewheel Flow Sensors (Signet 515, 2536, 2537)
Ultrasonic Flow Sensor
Vortex Flow Sensors (Signet 7000/7001)
In-Line Rotor/Flow-Through Sensors (Signet 2000, 2100, 2507)
|
|
|
|
|
|
Aalborg®'s multi-parameter PWE Enhanced Digital Paddle Wheel Flow Meters offer cost-effective solutions to medium flow liquid applications. Password-protected access to process parameters eliminates user-tampering or resetting. Flow rates can be displayed in 23 different volumetric or mass flow engineering units. In addition, flow meter parameters and functions can now be programmed locally via optional key pad and LCD or remotely via RS-232/RS-485 interface.
Simple in design with only one moving part, these units are easy to install & operate. Sapphire jewel bearings facilitate virtually friction-free impeller wheel rotations resulting in linear medium flow metering. PWE supports various functions including two independently programmable flow totalizers, self-diagnostic alarm, flow pulse output, and analog 0-5Vdc or 4-20 mA output flow & temperature signals.
Models constructed of Polypropylene or chemically-resistant PVDF can be mounted either horizontally or vertically. Designed for measuring highly accurate temperature readings, PWE Digital Paddle Wheel Meters are ideally suited to many flow system applications. Durable materials of construction ensure long operational life.
Enhanced Features
- Free communication software with temperature and flow data logging capability.
- Flow metering accuracy (inc. linearity) ±1% FS.
- Temperature accuracy (inc. linearity) ±0.5 ºC.
- Two sets of user-programmable optically-isolated outputs.
- Available with/without local key pad & 2x16 character LCD readout with adjustable back light which provide flow rate, total volume reading, diagnostic events indication, and protected access.
- Optional platinum RTD.
|
|
Optimum solutions for individual requirements
Endress+Hauser flow measurement systems offer optimum solutions to
match your individual requirements for applications in
- gases,
- vapors,
- conductive or non-conductive liquids,
- mass flow measurement
- volumetric flow measurement.
You have the choice of the following measurement principles:
- electromagnetic,
- Coriolis mass measurement,
- thermal mass measurement,
- vortex meter,
- ultrasonics
- differential pressure.
|
|
The contactless measurement and the lack of moving parts, allow a precise determination of the mass flow without any wear to the systems components. This outstanding advantage is applicable on various mechanical conveying systems like:
belt conveyors
screw conveyors
troughed chain conveyors
steel plate conveyors
bucket conveyors
free fall in chutes or pipes
This makes a radiometric bulk flow measuring system particularly interesting for various applications.
|
|
The C-LEVER® II by REMBE® sets the benchmarks in the field of industrial flow metering.
Its unique technique achieves an excellent accuracy of ± 0,25 % of the volumetric range for nearly all flowing bulk and solids.
The accuracy of the C-LEVER® II is almost independent from product, its density, form, friction and elasticity. Severe changes of flow and/or pulsations caused by rotary valves or screw feeders do not influence the accuracy.
Compared to conventional measuring systems - based on volume, speed or weight - the REMBE® system measures the product flow inline.
The C-LEVER® II is made without any mechanical moved parts (actuators, pivot bearings, belts). As a resulting from this no post calibration is required. All electronical components are mounted outside of the product flow.
|
|
|
|
|
|
Fuel flow meter DFM is a simple and easy-to-use fuel flow meter with electronic counter designed for measuring fuel consumption and engine operating time of vehicles, tractors, any mobile or fixed installations with diesel engines.
All readings are shown on the electronic display of the meter. Switching of indications is made by special contactless key.
There exist two modifications of fuel flow meter DFM: MT - monitoring of fuel consumption and engine operating time, T - monitoring of fuel consumption.
Fuel flow meter DFM is protected from overstatement of readings and intervention. Even if you try to blow the meter by air the fact of intervention will be registered.
Fuel flow meter DFM contains the following counters (* this counter is accessible only in MT version):
- Total fuel consumption counter, l
- Instant fuel consumption, l/h
- Total engine operating time counter, h *
- Engine operating time in “idling” mode counter, h *
- Engine operating time in “optimal” mode counter, h *
- Engine operating time in “overload” mode counter, h *
Advantages of fuel flow meter DFM:
- Monitoring of fuel consumption and engine operating time (MT version)
- Moderate price
- Strong metal molded case
- Built-in fuel filter
- Electronic correction of measurement inaccuracy in all flow range
- Ease of mounting and service
- Protection from overstatement of readings and intervention
- Measurement inaccuracy is no more than 1%
- Flow range (DFM-5 - 2...80 l/h, DFM-7 - 5...200 l/h)
- Temperature range -45...+60 ºС
- Separate account on engine behaviors
- Reliable electronic display
- Certificate of conformity (CE)
|
|
Open Channel Flowmeter FMC-4000/FCA
Flowmeter to mounting on waste-water open channels or boxes
This low cost mounting system allows to measure, totalizer, average and peak flow at small open channel and to transmit all data by Modbus communication, and optionally also Radio or GSM. Also optionally can be powered by means our stand-alone ABF device with solar cell, allowing to mount in isolated areas.
|
|
Continuously monitor, display, totalize and data log flow through any flume or weir. The OCF 4.0 includes a non-contacting ultrasonic sensor that mounts just 8" (203.2 mm) above the flowing water. It is accurate (±0.25%) and reliable. There is no obstruction to flow and no fouling. Use the built-in Keypad/menu system to select your flume or weir from the Menu and to choose measurement units (gallons, liters etc.)
- Non-Contacting Ultrasonic Sensor
- Accurate and Verifiable
- Built-in 50,000 point Data Logger
- Windows Software
- USB and RS232 Outputs
- 4-20mA/0-5V Output
- 16-digit Totalizer
- 3 Programmable Control Relays
- Password Protected
- Simple 3-key Calibration
|
|
Open Channel Flow Measurement Isco 4200
No single measurement technology is suitable for all open channel flow monitoring applications. Only Isco offers you a choice of ultrasonic, submerged probe, bubbler, and area velocity flow meters. Whether you need a permanent meter for a flume or weir, short term measurement with no primary device, or flow and pump performance monitoring at a lift station, Isco has the solution. And our application experts are available for a free, no obligation consultation to help you choose the best technology for your monitoring sites.
|
|
The EasyFlow is for professionals who occasionally do flow gauging and who don't need to record several measuring sites. It permits to realise in several minutes a flow gauging according to the tracer dilution method. The device records the salt cloud and gives the result in liters per second at the end of the operation.
Very ergonomic and waterproof, it is equipped with a conductivity probe with 10 meters cable. It is delivered in a small bag with shoulder strap.
SALINITY
Measuring range: 0 - 3200 mg/l
Sensitivity: 1 mg/l
Precision: < 1%
Salt quantity (min - max): 1g - 100 kg
TEMPERATURE
Measuring range: 0 - 40 °C
Precision: +/- 0,2 °C
FLOW
Precision (Optimum mix): < 5 %
Measuring display range: 0,1 l/s - 99'900 l/s
VARIOUS
Supply: 3 alkaline batteries 1,5 V type AA, AM3, LR6
Autonomy: ~ 100 hours under normal conditions
|
|
|
Equipped with the newest microwave technology, our solid flow meter MF 3000 is designed for flow measurement in metallic pipes from a few kg/h to many t/h. The system is suitable for on-line measurements of powders, dust, pellets, and granular from 1 nm up to 2 cm in pneumatic or free fall condition. Installation is simple and cost effective via a welded base, through which the sensor is screwed flush with the inside of the pipe.
|
|
The Working Principle
Bulk material supplied from above passes a constant-
speed impeller wheel driven by a three-phase current
motor, diverting the material radially. The tangential
Coriolis force acting on the wheel blades causes drive
torque changes in proportion to the flow rate sensed by
a load cell. Based on torque and speed, the Congrav®
microcomputer computes the current flow rate, which is
both displayed and issued as a signal for recording or
control of a variable-speed upstream feeder (e.g.
screw feeder, rotary valve).
The Advantages
Ingredient characteristics
or height of fall do not
affect accuracy
Models
CDW 150: max. rate 40 m³/hr
CDW 250: max. rate 100 m³/hr
CDW 350: max. rate 160 m³/hr
|
|
APPLICATION
Horizontal installation
For hot water up to 120 °C
Model 414 with carbide bearing
Overall and connection dimensions to DIN ISO 4064
DN15-50mm-PN16
DN 20 - 40 mm - with flange, PN 16 and PN 40 available
Operating pressure to DIN 2401
Max.24V,(SELV),0.2A
Protection class IP 65
Volume measuring component for measuring heat tor billing hot water consumption
Facility tor remote transmission of flow rates
Cable length: 3 m {0.25mm2)
|
|
APPLICATION
□ Fully electronic compact heat meter or compact cooling & heat meter with impeller scanning for recording energy and volume data.
□ Highly accurate recording of all billing data in a heating circuit or a cooling & heating circuit at medium temperatures up to 90 °C.
□ Horizontal and vertical installation, also overhead for Model 447/450.
|
|
|
There are two methods for the safe installation of flowmeters in hazardous areas. Either the electronics must be housed in heavy flame-proof enclosure with expensive armoured cable connections (Eexd/Flameproof) or the electronics can be intrinsically safe (IS). The preferable approach is that the flowmeter is intrinsically safe and is not capable of igniting volatile gases. A normal low-cost, non-armoured cable is used to connect the flow-meter to the safe environment where isolator barrier devices are installed. These devices limit the energy passing to the IS transmitter electronics.
|
|
| ... products without technical information |
| |
|
|