The Triathler gamma counter is a compact, portable, manual instrument for counting gamma labels in the 10 keV .. 500 keV energy range.
Key characteristics:
- 32 x 32 mm NaI detector, through hole, well diameter 14 mm. Background shield 8 mm of lead
- 1000 channel Multi Channel Analyser
- Max sample diameter 13 mm.
- > 75 % counting efficiency for I-125
- Optimised to count e.g. radio-immunoassay and cytotoxicity
- Single or dual label counting with spillover correction.
- 32 character alphanumerical display
- RS-232 port to drive a PC or a printer
- Preset nuclides:I-125, I-129, Co-57, Cr-51, Cs-137, Co-58
- Software for MS WindowsR to download the results to a file or MS Excel worksheet is included
- Remote control of the Triathler via the RS-232 port
- Power input: 12V DC, 1.5 A or 100 .. 240 V AC, 50/60Hz
- Mechanical data: H 190 mm, D 330 mm, W 250 mm, weight 9 kg
Delivered with:
- Owner’s Handbook
- PC interface software
- RS-232- cable
Available options:
- Additional internal lead shield, thickness app. 6 mm, weight 6.5 kg
- Equipment and field cases |
|
| The Dual-Channel Gated Photon Counter offers a convenient, integrated approach to photon counting that avoids the complexity and expense of older counting systems. No longer is it necessary to mix and match amplifiers, discriminators, gate generators and counters. The SR400 combines all these modules into a single, integrated, microprocessor controlled instrument. Complex measurement tasks such as background subtraction, synchronous detection, source compensation and pile-up correction can all be performed easily with the SR400. |
|
The new digital density meter DS7000 gets along with only 0,3 ml of sample quantity!
Additionally the density meter convinces with a measuring accuracy never seen before: in the measuring range of 0.00000 – 1.99999 g/cm³ the measuring accuracy is 0.00005 g/cm³. Whether you want to measure density, specific gravity or the concentration of liquid solutions: by this highly precise measuring instrument you receive results with 5 digits behind the comma. And even better: You receive your measuring result in only 1 second!
Behind these improvements stands a new-developed micromechanical measuring cell which needs only 80 µl of sample volume and provides an integrated temperature measurement of the sample.
Further features: built-in Peltier thermostat ensures precisely regulated temperature with a repeatability of +/- 0.02 °C, calibration certificate in accordance with N.I.S.T. density standard, particularly suitable for application fields in the GLP/GMP range, user-friendly touch-screen operates in 6 languages, interfaces RS232 and Ethernet, LIMS and printer connections.
990 programmable customized measuring methods (9 preset). The SQL data base thus stores and controls 999 results for you. Individual user management with separate passwords can be programmed.
The DS7000 can be used in a widespread range, e.g. for determination of mixing ratios, quality and quantity inspections. Operational fields are among others the chemical industry, pharmaceutical and cosmetics industry, breweries and beverage manufacturers, sugar and sweet material industry, pulp and paper industry, electronic industry, petrochemical industry and waste water management. |
|
Micromeritics new AccuPyc II 1340 Gas Displacement Pycnometry System are fast, fully automatic analyzers that provide high-speed, high-precision volume measurements and density calculations on a wide variety of materials. The AccuPyc completes most analyses in less than three minutes with excellent accuracy by using a gas displacement technique to determine absolute density of powders, solids, and slurries having volumes from 0.01 to 350 cm3.
The instrument can be operated with a keypad or an optional Windowsâ interface that provides exceptional reporting and archiving capability. Both versions include direct sample mass input from a balance and cycle-based displacement volume reporting. With the Windows interface, features such as time-based pressure equilibration reporting and additional calculations such as percent solids content and total pore volume are included.
For those who require high throughput, an integrated control and analysis module can control up to five additional external analysis modules. Each module can have a different size sample chamber (1 cm3, 10 cm3, 100 cm3, 350 cm3) providing even more versatility.
A multivolume option allows analysis of a variety of sample sizes in a single analysis module. A temperature-controlled version of the analysis module performs analyses at user-selectable temperatures.
|
|
| Thermo Scientific gas and liquid density meters measure density or density related variables within the oil and gas, petrochemical, chemical, food and beverage, and general process industries. These highly accurate, online, continuous meters use a proven vibrating element design to provide key information for process monitoring and control, quality control, product interface detection and custody transfer applications. With a twin tube design that is inherently more stable than single tube technology, the meters detect any variation of process constituents or final product quality in near real-time to improve productivity, minimize product waste and reduce costs when compared to sampling methods. The compact, lightweight meters are also easy to install without upstream flow conditioning or instrument supports. Once installed, the straight-through sensor offers an unobstructed flow path to ensure minimal pressure drop and higher flow rates. With hazardous area approvals and secondary containment on all models, these durable instruments withstand tough industrial environments to ensure a significant return on investment. |
|
The contactless and continuos measurement of the density of liquids or bulk material is requested in even more than the following applications:
Concentration measurement of acid, alkali, saline solution and suspension
Crystallisation and polymerisation monitoring
Determination of the solid matter content in slurries, in flue gas desulphurisation suspensions, in aluminium production and in mining
Measurement of the bulk density in washing powder and clinker
|
|
| The UGC Vibrating Densitometer accurately measures the density of a flowing fluid at actual operating conditions. This Densitometer was primarily developed for extremely accurate fluid metering (custody transfer), plus many other applications, such as pipeline interface detection, blending, process control, etc. The frequency output of the Vibrating Densitometer is compatible with most flow computers. |
|
Density Meter Series DIMF 2.0
Swagelok-screw joints, flange DN 15 PN 40, milk threads according to DIN 11851 PN 10
accuracy ± 0,2 kg/m³
reproducibility 0,05 kg/m³
operating temperature according to design -40°C to 210°C Accessoires
electronical transmitter
pre-amplifire
strainer
gas separator
processing peripherals
Density Meter Series DIMF 2.1
flange DN 25 / 50 PN 40
accuracy ± 0,2 kg/m³
reproducibility 0,05 kg/m³
operating temperature according to design -40°C to 150°C |
|
| The DENSITRAK® Model D625 liquid density meter utilizes the spring mass principle for measuring the fluid density. A portion of the "u" tube is energized to vibrate at its natural resonant frequency by using an electrical feedback driving system. A change in the vibrating mass, (as a result of change in the fluid density) shifts the resonant frequency. A CSI SPUD signal processing unit for density uses temperature, pressure and the shift in frequency to determine the density of the measured fluid. |
|
Digital density meters measure density, specific gravity and other related values (I.e. alcohol%, BRIX°, API degrees) with high precision and short measuring time.
Measuring principle:
A hollow glass tube vibrates at a certain frequency. This frequency changes when the tube is filled with the sample: the higher the mass of the sample, the lower the frequency. This frequency is measured and converted into density.
Benchtop instruments are equipped with a built-in Peltier thermostat to control the temperature (no water bath required). |
|
Applications
: In-line density measurement of liquids or multiphase-mixtures
Special features:
Reliability
Robust construction with magnetic transmission of measured values.
Can be used in hazardous areas.
No by-pass required
Wide and clear scale
|
|
The Wallace High Precision Densimeter is a cost efficient inspection instrument, calculating an accurate measurement of specific gravity. With a scale capacity of up to 300g and specific gravity resolution to three decimal places. The X22B is ideal for the inspection of rubber, plastic, sintered metals, glass and ceramics, foods and other materials. Using the optional liquid measuring kit the specific gravity of a liquid can be determined.
The innovative design makes specific gravity measurement simple and results are displayed after an elapsed time which varies according to the mode selected. Zero and tare are set through touch button operation on the front panel. The angle accessory (supplied as standard) enables samples with an SG of less than 1, to be tested. Compensation for temperature and for fluids other than water can be set by the operator. A built-in accuracy check is a standard feature so that if sample weight is insufficient, the final digit will flash. A wind shield is provided to protect the instrument from draughts and dust during operation.
Also available: X21 C with resolution to four decimal places |
|
Optical metrology equipment for climatologists and meteorologists
The laser ceilometer from JENOPTIK Laser, Optik, Systeme GmbH measures such atmospheric parameters as cloud height, visibility and the height of a planetary boundary layer. The product provides the first ever metrological device to safely detect also cloud layers and cirrus clouds at height levels up to 15 kilometers. This marks a major progress in the science of meteorological and climatologic forecasting. Measurement is accomplished with an opto-electronic laser sensor that relies on the LIDAR principle, an optical version of radar: A solid-state laser emits light pulses into the atmosphere. The light which is scattered by air and aerosol molecules is collected with a specific optical setup to be detected by a highly sensitive photo receiver (APD). By analyzing the pulse transit time and the intensity of backscattered light portions, smart algorithms compute a high-resolution aerosol height profile along with other related measurement readings. With integrated heating and cooling functionality and designed for autonomous operation, the CHM 15k can be relied to perform in any weather conditions.
|
|
Microprocessor meltingpoint measuring instrument with interface RS-232.
Measuring Range: 25-400 °C
Accuracy: up to 200°C +/- 0.3°C; 200°C-400°C +/- 0.5°C
Display: LCD Grafik Display
Heating Rates: to 300°C approx. 4min; to 400°C approx.7.5 min
Dimensions: 230x210x110 |
|
Multifunction meters from AHLBORN are suitable for the adaption of various sensors and are able to measure and store the data of nearly all physivcal, chemical and electrical variables. Also sensors with a non linear output signal are adaptable. Sensor specific linearisations can be programmed easily by the user. The linearisation will be stored inside the intelligent sensor connector. Between 5 to 9 sensors are adaptable depending on instrument version. The devices are easy programmable via menue guided displays. The indication of up to 3 measuring values is possible on the large, illuminated display. The indication can be also a grafic or a measurement list. The measurement values can be stored in the device or directly be transfered to a PC, either per cable or wireless. Complete software programms are available for professional data acquisition. The company AHLBORN offers with its flexible dataloggers and multifunction devices many possibilities for each kind of application and measurement task. The ALMEMO measurement techology is future orientated and easy to handle.
|
|
m3/h, m/s, CO2, %RH, °C, DP, Lux
•Instrument memory for up to 10,000 measurement values
•PC software for analyzing, archiving and documenting the measurement data
•IAQ probe, Lux probe and Comfort Probe
•Vane measurement and integrated differential pressure probe for Pitot tube measurement
•Wireless probes for temperature and humidity |
|
°C, %RH, °Ctd, g/kg, hPa, m/s, m3/h, ppm CO, ppm CO2, U/min, mA, V
•Simultaneous measurement at several measurement locations
•Data logger function
•Freely usable probe inputs
•1 to over 200 measurement channels
•Data transfer with the Testo data bus
•Modular setup of system components |
|
DTM 550 FEATURES
Temp:-20Ž~ 100Ž
Humidity:0 ~ 100%RH
3 1/2 Digit, Back light display
Use highly accurate RTD temperature sensor
MAX, DATA, HOLD function
Automatic low battery indication
Valox housing to withstand accidental
DTM 550SPECIFICATIONS
Measurement Range: Temp:-20Ž ~ 100Ž
Humidity: 0 ~ 100%RH
Temp. Accuracy: }0.5Ž-0Ž~50Ž, }1Ž-20Ž to 0Ž,50Ž to 100Ž
Humidity Accuracy: }2.5% RH (10% to 90% RH) ;}5% RH (90% RH)
Operating Environment: 0Ž to 50Ž at <75% relative humidity
Resolution: Temperature:0.1Ž; Humidity:0.1% RH;
Sensor: Pt385/1000Ħ,RTD temperature sensor
General
Power Requirement: 4 pieces 1.5V (AAA size) batteries
Dimensions: 6.7"x1.7"x1.6" (170x44x40mm)
Weight: 6.3 oz(180g)
Accessories: Soft carrying case, batteries, owners manual |
|
Measures the tension value in Hertz of all the accessory and timing belts.
- Optional : Diapabaz, catalog of values in Hertz
- Compact sensor, allowing easy access to the engine front side
- Can be used in a noisy environment
- No wear or maintenance
- Autotest of the measuring system integrated in device
- Multi trademarks |
|
Combining the two tools frequently used by every instrumentation technician,the ecom 789 Process Meter will be at home in every instrumentation technician ’s toolbox.The ecom Process Meter combine a DMM and a Loop Calibrator in one rugged,handheld tool. With its built-in 24 V loop supply it reduces the need for taking a separate power supply when doing off-line transmitter testing.
|
|
A belt drive achieves its maximum lifetime when it is configured specifically to the application, the belt is perfectly tensioned and the pulleys are precisely aligned.
The TRUMMETER is an electronic measuring instrument that consists of a measuring probe and a microprocessor and is used for measuring the belt tension and checking the strand force of a belt drive.
The measurement result is displayed either in hertz, newtons or poundforce.
This measured value can be compared with the nominal value – specified by the belt drive manufacturer (as a natural frequency in Hz or a strand force in N). It is dependent on the characteristics of the drive. |
|
hese belt grinding attachements can be mounted to any lathe or stone grinding machine. They are easy to operate and reliable in operation
• zum Anbau an eine Drehbank
• einsetzbar mit Schleifbändern oder Polierscheiben
• Bürsten, polieren und satinieren
• Für alle Drehbänke
• Pendelschleifaggregat
• Pneumatischer Anpressdruck
Technische Daten:
Applications:
Surface improvements prior to plating, descaling, deburring, superfinishing, finishing for surface checking by ultrasonic, removing surface defects, decorative grinding and polishing, microfinish surface, satin finishing, chrome finishing, improving corrosion resistance, removing of coatings ...
Workpiece and parts:
Tubes, bars, pipe, profiles for furniture industry, decorative stainless, shop interior, engine components, axles, precision engine parts, paper tubes, fiber and kevlar tubes, golf shafts, stainless tube, heat element, door handle, peeled bar, hydraulic cylinder rod, telescopic cylinders, chrome bar, steel bar, boiler tube, rods ... |
|
| There are two methods for the safe installation of flowmeters in hazardous areas. Either the electronics must be housed in heavy flame-proof enclosure with expensive armoured cable connections (Eexd/Flameproof) or the electronics can be intrinsically safe (IS). The preferable approach is that the flowmeter is intrinsically safe and is not capable of igniting volatile gases. A normal low-cost, non-armoured cable is used to connect the flow-meter to the safe environment where isolator barrier devices are installed. These devices limit the energy passing to the IS transmitter electronics. |
|