|
|
Since 1984 B&B Thermo-Technik develop and manufacture successfully industrial temperature probes.
New ideas were always a reason why B&B is one step further than its competitors. Our customers are the focus of our thinking and acting. For them we investigate, analize and realize almost everything in the temperature measurement.
B&B Thermo-Technik is specialized in the production of gas analysis probes. Just send us your inquiry and we will supply you with an detailed offer and the solution for your measuring problem.
You will find our range of standard sensors in our Online-Shop:
www.temperature-shop.eu
There you will also get more information about our range of temperature measuring technics:
- Temperature / Manufacturer of humidity sensors
- Thermocouple manufacturers Connectors suppliers
- Digital Thermomters
- Infrared Thermomters
- Stationary Pyrometers
- Controllers
- Indicators
- Data Loggers
- Hygrometers
- Professional transmitters |
|
Bühler Unheated sample gas probe with shut off cock and in-situ filter
For dust concentration up to 200g/m³, no condensate containing gases
For hazardous areas, no internal ignition point
Technical Data:
Material: 1.4571, industrial ball valve 1.4408
Professional seals: PTFE/graphite/1.4404 and see filter element
Operating temperature: max. 200°C
Max. working pressure: 6 bar
Order information: Base unit:
GAS 222.30 p/n 4622230
Options:
To customize the base unit to meet the needs of any application, please refer to data sheet DE461099 "Accessories for Gas Sample Probes”.
Unheated extensions
Professional filters
Calibration gas port
ANSI flange 3"
Manufacturer of pneumatic actuator
Blowback
Blowback control unit |
|
The gas sample probes are used for continuous extraction of gases from dust loaden, high temperature or humid processes for the gas analysis.
Unheated, heated, explosion proof and portable versions are available.
Due to its modular design the gas sample probes can be adapted to nearly all process conditions.
. |
|
Bühler Heated sample gas probe with downstream filter and weather protection shield
Filter can be replaced without tools
Effective insulation and protection shield
Self-regulating up to 80°C
Dust concentration up to 2g/m³
This probe is approved for use in Zone 1, 21 and for gas sampling from Zone 0, 20 (hazardous areas)*.
Technical Data:
Material: 1.4571
Professional seals: Graphite/1.4404 and see filter elements
Max. working pressure: 6 bar
Max. flow 1000 l/h
Max. inlet temperature process media 135°C
Voltage: 230 V, 50/60Hz
or 115 V, 50/60Hz
External circuit-breaker Type C:
2A for 230 V, 50/60Hz
3A for 115 V, 50/60Hz
Ambient temperature -20 to +50°C
Temperature: self-regulating approx. +80°C
Ex-marking of the basic unit *:
1GD / 2GD T4 T130°C
Order information: Baise units:
GAS 222.20 Atex 230V p/n 4622220X2
GAS 222.20 Atex 115V p/n 4622220X1
Options:
To customize the base unit to meet the needs of any application, please refer to data sheet DE461099 "Accessories for Gas Sample Probes”.
Various probe tubes
Unheated extensions
Industrial filters
Calibration gas port
ANSI flange 3"
* Please note that installed accessories may change the approved category of the probe. (Regard type plate and operating instructions) |
|
| For nuclear manufacturers of power plant industrial steam generator tubes, Zetec's Compliant Low Noise (CLN) bobbin probe uses advanced materials, design, and production to provide clean eddy current data that is consistent through the life of a probe and the duration of inspection. The CLN probe's immunity to ambient noise sources and ability to dissipate electrostatic charges ensures reliable data quality and more consistent probe-to-probe performance. The CLN probe is highly flexible for navigating small radius u-bends, yet maintains high data quality and minimal data drift in straight sections. Whether analysis is automated or performed manually, Zetec's CLN bobbin sets a new standard for efficient and accurate inspections. |
|
| The Clif Mock sample probe was the first truly isokinetic sampler available for crude oil sampling and is still the most accurate and reliable method for extracting a sample from a pipeline for BS & W analysis. Designed to be used with C-22 Isokinetic Professional samplers, the CD20 drive units are available in four configurations and are capable of pulse counting, timing, pacing from computer and sending out a "loss-of-signal" alarm. In the last few years, there has been increasing demand for much more elaborate systems. These CLIF MOCK True Cut systems commonly have multiple receptacles for separate products or batching operations and have controllers, which interface with central computer systems. |
|
The vessel, capacitance industrial electrode and medium to be measured form together an electrical capacitor manufacturers. The level change is monitored as a direct result of the variation in capacitance value around the probe, dependent upon the degree of immersion.
Advantages
- Rugged detection suitable for universal applications
- High chemical resistance
Applications
- Level measurement and level detection of liquids and solids
|
|
KONTINUIELICHE LEVEL METERING
- capacitive level probes for liquids and bulks in
High-grade steel or plastic one, exit 4-20mA, for vertical installation, for
aggressive media, remarks with removable head and
exchangeable or shortenable probe staff
- Niveausonden with float principle, for liquids, exit 4-20mA
or resistance signal, Kundensprezifi remarks, in high-grade steel
or plastic ones
Level border conditions: Capacitive contactors,
optical contactors,
Float switch |
|
| ... products without technical information |
| |
Verimation Technology, Inc. produces various standard and custom probes and coils for our Verimet Line of Eddy Current Instrumentation.
Available Standard Probes and Coils are:
N7300 Probe for Seam and Crack Detection
N900 Probe for Hardness, Alloy and Case Depth
N900 ¡°B¡± Coil for Hardness, Alloy and Case Depth ¡Ü 1 inch (900M108)
N900 ¡°C¡± Coil for Hardness, Alloy and Case Depth ¡Ý 1 inch (900M108) |
|
Find the radiated emi emission source
A typical emi emission is test conducted using a broadband EMC professional antennas in the far field such as biconical, log periodics and horns. Usually at 1, 3 or 10 meter distance. If the product's emissions levels are above the levels set by test standard, the cause of the emission must be identified by the test engineer. The near field probes are used to find source of the emission at circuit level of the product. A typical EMC antenna is physically too large to make these measurements. The small hand held near field probes included in the PS-400 and PS-500 probes sets will allow test engineer to probe hard reach areas of the product. |
|
Features:
- Large Bright High Resolution Color Touch screen manufacturer
- Built-In Industrial encoder Interface
- USB, LAN, VGA outputs
- Huge Data Storage Capability
- Longitudinal, Shear, Guided, and Surface Waves
- A-Scan, B-Scan, CB-Scan, and TOFD
- Corrosion Profiling and Flaw Imaging
- Up To 20m Length of One Line Scanning Record
- Playback A-Scans for Recorded Images
- Enhanced Signal Evaluation - Live and Frozen A-Scans
- Defect Sizing and Pattern Analysis
- Compliance with ASME and RBIM Procedures |
|
A wide range of industrial electrodes and probes are conceived for different uses : water, wastewater, food, textile, paper, pharmaceutical, cosmetic, chemical industries.
A platinum resistance Pt 100 incorporated assures the mesurement and the automatic correction of temperature.
Wide ranges of adaptations :
- in tanks: canes up to two meters
- on pipes: stainless steel, polypropylen, PVC
- in reactors: sleeves to be soldered |
|
| ... products without technical information |
| |
| Since its introduction, the PrecisionPoint™ VX platform has been the industry standard for dependable test, analysis and rework of your probe cards. The PrecisionPoint VX3 carries on this tradition for today's fine-pitch, small array probe cards. From logic to LCD drivers, the PRVX3 provides the necessary tool set to meet your testing needs for planarity, alignment, Cres, leakage, probe force and more. |
|
| ... products without technical information |
| |
| The MTI Instruments Apex Series Eddy current probes offer superior performance at an economical price. flexible in design, these systems allow custom configurations to match your process needs. With linear measurement ranges from 0.5 mm to 50 mm and frequency response of up to 10 kHz, they are ideal for displacement and vibration applications that require high-speed, rugged sensors. Eddy current detectors have unique advantages over other non-contact measurement technologies in that they are unaffected by water, oil or other contaminants in the measurement area. |
|
Sensonics range of SENTURION eddy current probes are designed to be the most robust
and reliable units available, and are ideally suited to a vast range of industrial applications.
The SENTURION eddy current probes are intended for use within a system comprising of
the probe, an extension cable (if required) and a driver unit. The probes are supplied in
tuned lengths, and can be linked directly to the driver or via the afore mentioned extension
cable. However the system is connected the total lengths must add up to 2, 5, 7, 9 or 14
metres. |
|
| CBS (Chamfered Barnacle Professional scraper) probes are Zetec's most popular solution for basic tubing inspections. As the name implies, these probes are designed to push through and 'scrape' away residue to make sure that the entire length of each tube can be inspected. These probes are available in both the standard economical version as well as a heavy duty 'long-life' version. Intended primarily for inspection of straight sections of non-ferromagnetic tubing, these probes are typically offered in diameters of 10mm (.400") to 25mm. |
|
Conducted currents can be measured without making direct contact with the source conductor or metallic surface by means of clamp-on broadband current probes. The BCP-5xx EMC Current Probes are designed to permit field intensity meters, spectrum analyzers, and other 50W impedance instruments to measure quantitative magnitudes of current. Measurements can be made on single and multi-conductor cables, ground and bonding straps, shielded conduits and on coaxial cables. We have 11 models of Broadband Current Probes. Please vist our website for more details. www.AHSystems.com
|
|
| ... products without technical information |
| |
The FCR-7xx200-2 is a standard reflection probe to get spectral information of diffuse or directly reflecting or back-scattering materials.
Via a standard SMA905 manufacturers of connector light from a light source is coupled into a fiber bundle, consisting of 6 fibers and carried to the probe end. The surface will selectively reflect light back into a 7th fiber. This fiber transfers the data to the output SMA905 connector, which can be coupled to a spectrometer manufacturer or spectrum analyser.
A higher number of fibers are possible to couple more energy from the light source and to increase the signal level.
For measurements under 90º the FCR-90-Option, a special adapter with a mirror under 45º, was developed, which can be easily mounted on the tip of the reflection probe.
The FCR-COL is available to focus the measurement spot on an extended distance.
|
|
Specifications:
* LF-190E 60MHz :
- 60 MHz Oscilloscope Probe
- ITEM 10 : 1 Bandwidth
- DC~40MHz( +/- 1dB), DC~60MHz(+/-3dB)
- Item: 1: 1
- DC~3MHz(+/-1dB), DC~6MHz(+/- 3dB)
- Input R 10: 1 =10M Ohm = 22pF
- Input R 1:1 =1M Ohm (Oscillosocpe) = 180pF
- Input C : at Oscilloscope Input 20pF
- ATT Ratio : 1 / 10 ; 1 / 1
- MAX Input Voltage DC 600V
* LF-210E 100MHz :
- 100 MHz Oscilloscope Probe
- ITEM 10 : 1 Bandwidth
- DC~60MHz (+/- 1dB), DC~100MHz( +/-3dB)
- Item: 1: 1
- DC~6MHz (+/- 3dB)
- Input R 10: 1 =10M Ohm
- Input R 1:1 =1M Ohm (Oscillosocpe) = 150pF
- Input C : 10:1 =14pF / 1:1 150pF at Oscilloscope Input 20pF
- ATT Ratio : 1 / 10 ; 1 / 1
- MAX Input Voltage DC 600V
* LF-250 250MHz :
- 250 MHz Oscilloscope Probe
- ITEM 10 : 1 Bandwidth
- DC~250 MHz(+/- 1dB)
- Item: 1: 1
- DC~6MHz( +/- 3dB)
- Input R 10: 1 =10M Ohm
- Input R 1:1 =1M Ohm (Oscillosocpe)
- Input C : 10: 1 =14pF/ 1:1 = 150pF at Oscilloscope Input 20pF
- ATT Ratio : 1 / 10 ; 1 / 1
- MAX Input Voltage DC 600V |
|
A 1180 - CO2 probe
CO2 probe is used for carbon dioxide measuring in crowded places, such as schools, hospitals, hotels, universities and industry. It should be plugged to Multinorm instrument
MI 6201.
|
|
|