V-Port Ball Valves (VPB)
Product Description
Major Markets: Paper, Chemical, Power, Petro-chem and Gas
Design Features: The V-Port Ball Valve is a quarter-turn v-orifice ball valve for accurate throttling control of fibrous suspension applications plus clean, dirty viscous, and corrosives liquids and gases. It is designed to meet the highest industry standards for dynamic performance. Flanged or flangeless designs meet ANSI or ISA face-to-face dimensions. Design features include blow-out proof shaft protection, high flow capacity, splined ball-to-shaft connection for ease of maintenance and zero backlash. Seat options include flexible metal, rigid metal and PTFE seats.
Size Range: 1 - 20" (25 - 500mm)
Temperature Range: to 575°F (300°C)
ANSI Class Rating: 150, 300
Pressure Rating: to 285 - 740 psi (1965 - 5100 kPa)
ANSI B16.104 Shutoff Class: Flexible Metal, ANSI Class IV* Reinforce PTFE, ANSI Class VI Rigid Metal, ANSI Class IV
*Shutoff is up to 500 times better than ANSI Class IV
Body Materials: Carbon steel, 316 and 317 stainless steel, Hastelloy C
Valve Style: V-Port ball, flanged or flangeless
|
|
High tech and sturdy air operated valve, with a floating
plug seal, meeting stringent use criteria.
An extra thick body of the actuator and of the valve, ensuring a good resistance to mechanical and thermal distorsions.
A modular design enabling the following configurations:
Shut off valve DCX3 L
DCX3 T
DCX3 X
Divert valve DCX4 L/L
DCX4 T/L
DCX4 L/T
DCX4 L/X
PFA seals quality ensures a complete sealing at high temperature and a good resistance to aggressive products.
Plastomer seal can be replaced by elastomer seal
Single or double acting connection
With plastomer seal, vertical setting up (especially for DCX4)
Dimensions 1” - 1-1/2” - 2” - 2-1/2” - 3” - 4” - 5” - 6” Material
Body: 316L stainless steel
Shut-off unit: 316L stainless steel
Manual or automatic operating devices: 304 stainless steel
Plug seal: PFA and elastomer
Stem seal: viton, EPDM, silicone
Options
• Signal back equipment on the top of the actuator
• Sterilization of the stem through an upper guide bearing
• External = 47 RA max (150 grit)
• Internal = 32 RA max (180 grit)
Upgraded finishes upon request:
Surface Finish
Variants
Plug and body machined for a metal to metal sealing (without seal)
Elastomer sealing (specific plug with viton, EPDM o-ring)
Manual operator device (instead of the actuator
Tank bottom type
Long stroke valve available upon request |
|
The TH8080 is a physical layer device for a single wire data link capable of operating in applications where high data rate is not required and a lower data rate can achieve cost reductions in both the physical media components and in the microprocessor which use the network. The TH8080 is designed in accordance to the physical layer definition of the LIN Protocol Specification, Rev. 1.3 and 2.0 and SAE J2602.The IC furthermore can be used in ISO9141 systems.
Because of the very low current consumption of the TH8080 in recessive state it's suitable for ECU applications with hard standby current requirements, whereby no sleep/wake up control from the microprocessor is necessary.
|
|
| We invented the charge-pumped RS-232 transceiver. Today, we are the leader in copper-wire data transfer, at speeds up to 800Mbps. Our product line includes USB, RS-232, RS-485, LVDS, and IrDA transceivers as well as Logic Level Translators, UARTs, and SCSI termination products. |
|
| LVDS & CML (Buffers and SerDes) Nationals leading edge LVDS and CML multi-megabit & -gigabit products include signal conditioners, serializers/deserializers (SerDes), drivers/receivers/transceivers, crosspoint switches, muxes, 1:n repeaters, buffers, and much more that drive LVDS, M-LVDS, PCI Express, SATA, SAS, XAUI, 4G FC, DVI/HDMI, and CPRI signals over low-cost cables and long FR4 traces. Serial Digital Interface and Data Transmission. |
|
| Industry standard single and dual drivers and receivers for RS232 and RS562 are available for power supplies from 1.8V to 5.5V with high ESD protection. DTE or DCE configurations are available in 3.3V or 5V versions. |
|
| Flow-control management devices are a new category of semiconductor solutions that save precious design time and resources by replacing expensive ASICs and FPGAs ordinarily used to solve data-flow-control issues in a communications system design. |
|
| With explosive growth in high-speed access and optics technology, and increased user demand for bandwidth, today’s communications network is becoming a bottleneck. To satisfy the users of tomorrow, communications networks must surpass their current levels of performance while creating new revenue-producing services. With a wide variety of traffic for voice, video and data sharing the network, equipment vendors must deliver traffic at high rates, with a high degree of reliability and cost-effectiveness, and with the ability to differentiate traffic services at wire speed. |
|
| IDT offers a broad telecommunications semiconductor portfolio, including products for access and transport, TDM switching and voice processing. IDT provides the industry's leading portfolio of T1/E1/J1 transceiver, LIU and framer products, the widest selection of time slot interchange (TSI) switches and the industry's highest density voice CODEC. These telecom products are used in a variety of communications applications, including multi-service aggregators and provisioning platforms, wireless base stations, enterprise routers and media gateways that are critical to enabling and accelerating the convergence of voice and data networks. |
|
| ... products without technical information |
| |
| ... products without technical information |
| |
| HOERBIGER products are characterised by excellent quality and high level of functional security even in extreme environments. Tests in line with standard usage in our company-owned test department offer optimal conditions for consistent quality. |
|
Hydraulic control unit HCD4-W containing PASCAL pump (air-driven hydraulic pump ) generates a hydraulic pressure (10.6MPa)
by air pressure (about 0.5 MPa). Pump action stops when the hydraulic pressure reaches the designated level, and keeps it.
Coupling valve VCB is to be installed between double action clamps and control unit. The control unit and coupling valve can be
separated by using a hydraulic coupler. Coupling valve has a non-leak feature which assures a thorough sealing. |
|
Dispenser VO40
Description:
Modular dispenser in open center. Operation with pump with fixed cubic capacity. Flow max = 40 l/mn
Advantages:
Modularity, maneuverability, repeatability, Ergonomics, stability of operation, compactness, facilitated maintenance
Applications:
Agricultural machinery, carts elevator, small cranes...
|
|
| ... products without technical information |
| |
FEATURES:
- Control/Monitor/Alarm via GSM mobile phone, no distance limitation. User can control/monitor/alarm their devices all over the world.
- 8 channels Analog input (4 -20 mA)
- 8 Relay outputs
- 8 Switch inputs, normal open, close alarm
- 8 Analog inputs: system can preset 4 mA and 20 mA input value according the real measuring value and setting display unit. It can read actual measuring data via the SMS (Short Message) requested, such as CH1= 28.0 C. CH2=53.7 %RH, CH3=7.01 pH........CH8= 230.5 ACV.
- Enable or disable Analog input alarm (High alarm, Low alarm) via SMS.
- Enable or disable switch Input alarm (close alarm) via SMS.
- Set relay output On/Off via SMS
- Dot matrix LCD display show Analog input value, Switch input and Relay output status.
- All setting value will be saved into EPROM IC, no loss.
- Mobile telephone can call out all channel measuring value, status of Switch input and Relay output at any time.
- Can default two telephone no., alarm SMS can be sent to two users.
- Build GSM mobile modem (dual band).
- After the SMS command sent by mobile phone, the confirm message will be sent back to the mobile, safe and no loss.
- Intelligent application , innovation, wide range, no limitation |
|
GSM Intercom
The GSM Intercom interface converts any existing intercom call point into a full GSM intercom system
1. Simply connect 3 or 4 wires normally connected to the intercom to this unit to GSM enable it.
2. No more missed callers
3. No giving away to strangers there is no one home when the intercom is not answered.
Caller ID GSM Access Control
1. The Unit will open gate, barriers, doors, mag-locks, barriers and shutters by recognizing the caller ID of the person calling it.
2. 1000 User Memory
Two Alarm in and Two Relay Out
1. Additional relay to control external items such as lights, power , heating, cooling or even the hot-tub.
2. Call into the unit and enter a password to switch the addition on board relay on
3. Connect sensors or an alarm system and be alerted by call or text any problems.
Product Specification.
1. Quad band Module
2. Operating Temp %u2013 25c %u2013 55c
3. Humidity Less than 95% RH
4. Lightning protector 3 -5 W
5. 2 output relay
6. Calls up to 3 numbers outbound
7. Battery backup for up to 8 hours
8. Caller ID for up to 1000 users
9. Programmable via SMS or voice or PC
10. Optional LCD programming
11. Comes with IP 65 enclosure
12. CE Approval |
|
1.Use as the telephone line backup in alarm system - Phone lines can easily be cut off during storms, construction work, accidents,deliberate tampering by intruders. will checks the status of the telecom line in alarm system and in case the telecom line become unavailable, will transmit the alarm using GSM to the alarm receiving center (ARC) or Center Monitoring Station (CMS)
2.Automatically call to 8 pre-program phone numbers while alarming. also will SMS to 8 programmable cell phone number to notify the user that the PSTN line has been cut off or unavailable
3.Programmable Contact ID - has built-in alarm inputs that allow the unit to send additional signals (with user programmable Contact-ID event) to the monitoring station. Supported Protocol: Pager message (DTMF no handshake)
4.Three Remote Controlling Outputs - These open collector outputs (that can sink max 300ma per output) can be turned on and off remotely through a SMS. You can use them to pull to ground your inputs. Remote control will be reachable by sending a SMS with a certain command. For example, switch on lighting, air conditional, or switch off generator, sensor using your mobile phone. |
|
The AST-100 is the world's most innovative means of viscosity control. The AST-100 is a versatile instrument that is excellent for customers who are looking for viscosity control (i.e. maintaining the viscosity of the product) in their process more than the measurement of an exact number (ex. 23.5cP). It is easy to install, cleans-in-place, and has no moving parts, so maintenance is minimal. With available options it is suitable for explosion-proof applications or 3A food-grade applications as well.
|
|
MIVI PROCESS VISCOMETER FOR INLINE, ONLINE AND ON REACTOR APPLICATIONS
Simple, Rugged, Reliable, No wear part, Low maintenance, Operates in any position, Easy installation
GENERAL TECHNICAL DATA
• Maximum working temperature up to 200 or 300°C
• Maximum working pressure up to 60 bar or 150 bar (500 possible at request)
• Maximum viscosity range up to 1000 Pascal.second
• Watertightness of the body IP67
• Material 316L SS, Hastelloy, ...
• Protective coatings Diamolith, PTFE, enamel
• Exproof approval ATEX, FM, JIS
• Sanitary design on request
INDUSTRIES :
Petrol, Petrochemical, Chemical, Food & beverage, Cosmetics, Printing & coating
APPLICATIONS :
Polymerization control, Heavy fuel oil control, Inks control...
PRODUCTS :
Oil, Polymers, Fuels, Bitumen, Resins, Gels, Emulsions, Cheese, molasses, Paints, Inks... |
|