|
|
|
NETGEAR's Double 108 Mbps Wireless Adapters connect desktops and laptops to the network in conjunction with a Double 108 Mbps Wireless Firewall Router. Together, they allow users to access both a normal 108 Mbps network and a private 108 Mbps network, which avoids interference by other neighboring wireless traffic. The second wireless network acts as a "carpool lane", free from other traffic and thus suitable for applications such as video streaming. In addition, new XR technology can achieve range up to three times greater than standard 802.11g.
|
|
|
Interface IC solutions ranging from CAN, LVDS, RS-485, RS-232 industry standards to 1394 (Firewire), USB, PCI Cardbus and more.
|
|
|
Jennic's Serial RapidIO system-level IP product line provides a complete range of fully integrated Serial RapidIO interface solutions, intended for integration into SoC semiconductor devices. Serial RapidIO is a data communication standard provisioned for the interconnection of devices on the same circuit board or between circuit boards across a backplane. It has been developed as a more cost-effective, standards, switched based replacement for expensive proprietary busses in high-performance embedded systems, such as networking and communications equipment and enterprise storage.
|
|
| ... products without technical information |
| |
The TCIC is Low cost high speed 8 channels thermocouple measurement interface board with USB and RS-232/485 interface. The TCIC supports thermocouple types J,K,E,R,S,T or ±500 millivolts at 1 microvolt resolution.
Main features:
On board cold junction compensation
On board temperature conversion functions enable stand-alone operation
USB interface as standard or USB + RS-232 /RS-485 (option)
Multiple boards may be connected via USB or RS485
8 opto-isolated outputs configurable as setpoints, latching alarms or user outputs
Comes with very useful software package and data logger
|
|
RJ45 Interface Modules
Features:
- Ease of connection with the use of standard screw connection Terminal Blocks.
- Housed in V0 fire retardant grade PVC mounting track.
- Possibility of having standard / cross-over connection using the same module.
- Mounting options available: DIN Rail mounting & Panel mounting.
- Voltage rating: 125 VAC RMS.
- Current rating: 1.5 AMP (max.)
- Contact resistance: 30 milli ohms max.
|
|
|
|
|
|
Key features
- Available as Starter kit
- Strain gauge, Pt-100 and potentiometric sensors
- CAN Interface
- 18 Bit A/D converter resolution
- Up to 5 Km cable
- Selectable bus-speed
- Daisy chain upto 60 devices
There is an increasing tendency to investigate the behaviour of large constructions under varying load conditions. Examples are: bridges, wind turbines, tower cranes, etc. Usually it is quite inconvenient to apply half- or full straingauge bridges onto such constructions, for which reason mostly single (1/4 bridge) gauges are utilized. This, however, usually implies cumbersome wiring to the inputs of the (remote) measuring amplifiers.
StrainBUSter has been developed to solve these problems by placing the measuring circuit in the direct vicinity of each point of measurement. Here all signal conditioning is done, after which all measured values are being transmitted via a CAN bus to one convenient central place, thus building one decentralized system. In this way, up to 120 measured values can be transmitted very reliably over longer distances.
Each StrainBUSter module has 2 separate input channels. The single straingauge, or the Pt100 sensor, is connected through a 3-wire connection, eliminating cable losses at the input side.
|
|
|
The DiskInterface is the interface used for downloading data and programming the SterilDisk and PasteurDisk dataloggers. It allows the communication between the datalogger adn its management program, the SPD software. It works with a serial (RS232) or USB port.
|
|
The main task of interface units is the trouble-free conversion of standardised plug-in connector systems to single conductor wiring or to another connection system.
Given the need to reduce costs in switch cabinet construction, interface units offer an alternative to wiring concepts with point-to-point wiring.
The prime function of interface units is to act as a trouble-free adapter element between standardised plug connectors and point-to-point wiring or other connection systems.
Advantages of the interface units:
Two- and three-storey PCB terminals save space
Conventional point-to-point wiring only needed on one side to save costs
Greater safety, preventing wiring errors
Optional: LED status display on the interface units
Rapid troubleshooting with additional test and measuring devices
Simplified initial commissioning and documentation.
|
|
| ... products without technical information |
| |
|
This product is an interface board of PCI bus conformity equipped with Bus master transfor in accordance with IEEE - 488.1 and IEEE - 488.2. It can perform communication control or data analysis of GPIB bus line of various machinery having GPIB interface with a PC. GPIB communication driver (API-PAC(W32)) for Windows version GPIB communication, LabVIEW Attachment. Using a collection of ActiveX components for measurement system development sold separately[ACX-PAC(W32)], you can more easily develop a higher-performance application in a short term
|
|
PCI-488
- IEEE 488.2 Standard Interface
- Complete Talker/Listener/Controller
- Data transfer rates over 1 megabyte/sec
- 1024-word FIFO buffer
- 7 Interrupt lines, shared interrupt capability
- Lifetime warranty
- RoHS compliant
- Includes GPIB-488 software library for Windows XP, Windows 2000, and LabVIEW
|
|
|
GPIB products offer three key benefits that can help save you time and money throughout the life of your instrument control system - from development through production and maintenance. You can rely on hardware and software that offers improved performance, high reliability, and increased productivity.
|
|
|
AS-Interface networks up to 62 field devices onto a single pair of wires that delivers both signal and power. Actuator Sensor Interface, or AS-Interface, was developed by a group of sensor manufacturers and introduced into the market in 1994. Since that time, it has become the de facto standard for discrete sensors in process industries throughout the world. AS-Interface may be used in hazardous process environments using explosion proof, tray cable, nonincendive and for nonincendive wiring protection concepts.
|
|
| ... products without technical information |
| |
|
|
|
|
Whichever RFID system you connect to SIMATIC PLCs, PCs or PLCs from other manufacturers: the communication module provides for the necessary adaptation. In doing so, communication modules can be employed both for production and logistics applications. With the function block FC/FB 45, the readers of all RFID systems can be handled standardized. This ensures that existing RFID applications are operational immediately and do not have to be rewritten when another reader type is used.
Optimal integration into the SIMATIC world (TIA)
- ASM 456 for PROFIBUS
- RF180C for PROFINET
- RF170C for distributed I/O ET 200pro
- ASM 475 for SIMATIC S7-300 and ET 200M
Various connector concepts (e.g. M12, RJ45 or ECOFAST) for the application connection
Comprehensive diagnostics functions
Firmware update via the SIMATIC Manager
Identical and convenient programming of all RFID systems from within the SIMATIC PLC
Easy, central management of all RFID components through the "Identification & Maintenance" functions
Connection of the RFID systems to PCs and PLCs from other manufacturers by support of the RFID standard profile
|
|
|
|
|
|
With BL ident the user is free to choose interface modules in IP20 or IP67.
Interface modules with PROFINET-DP (DPV0 and DPV1), DeviceNet, Ethernet/Modbus TCP/IP, Ethernet/Profinet and Ethernet/IP with up to 8 channels are available.
Programmable gateways enable decentral and fast signal processing.
The modular concept allows the user to add input and output modules to the interface at a later stage.
All channels operate in parallel allowing data to be transmitted simultaneously.
The diagnostics for the fieldbus, the supply voltage and the individual channels is carried out via LEDs and complemented by fieldbus-specific diagnostic messages.
Standard function modules are available for simple integration in the control and fieldbus environments.
The application of the BL ident simple module (BL20-2RFID-S, BL67-2RFID-S) is also possible. This way the communication is built on the basis of an 8-byte I/O module. The programming effort is reduced considerably. The user has the freedom to link BL ident to all standard control systems without using function modules.
|
|
The RF identification system for production control.
- DTS125: Industrially compatible identification system in 125 kHz technology.
- Coding of workpiece carriers in routing conveyors.
- Quick and easy set-up: Plug and play.
- Read/write head requiring little space due to narrow design.
- Compact and at a low cost: Antenna and evaluation in one housing.
Innovation in production control
The constant increase of the degree of automation in modern production plants is increasingly supported by identification systems. Their tasks include for example the control or release of production steps or the assignment of information about each product.
|
|
| ... products without technical information |
| |
The wireless Access control system consists of a control center and up to 240 hand-held transmitters.
Features
* Can be used just like a garage door opener
* Every transmitter has an unique code
* No DIP-switches, codes can not be changed
* If a transmitter is lost, the access of this user can be deleted
* Function check with three light emitting diode
* RS232 serial data interface
* Offline- / online software tool for windows to manage access and users (optional)
|
|
The RF identification system for production control.
- DTS125: Industrially compatible identification system in 125 kHz technology.
- Coding of workpiece carriers in routing conveyors.
- Quick and easy set-up: Plug and play.
- Read/write head requiring little space due to narrow design.
- Compact and at a low cost: Antenna and evaluation in one housing.
Innovation in production control
The constant increase of the degree of automation in modern production plants is increasingly supported by identification systems. Their tasks include for example the control or release of production steps or the assignment of information about each product.
|
|
|
|
|
|
* USBscope50 is a tiny PC based oscilloscope which connects via the USB port, combining the ease of use, portability and economy of PC based scopes with high performance normally associated with much larger bench oscilloscopes.
* USBwave12 is a new concept in USB function generator products. PC based function generators offer many user benefits including flexibility, ease of use and economy.
The USB interface has developed into probably the best and most widely implemented PC peripheral connection method and is a natural choice for the function generator.
* USBpulse100 is a new concept in USB Digital Pulse/Clock Generator products. PC based pulse generators deliver many user benefits including flexibility, ease of use and economy. They are an invaluable tool during design and debug of digital circuits and can be used to quickly test the behaviour of a circuit under different input frequency and duty cycle conditions.
* USBcount50 is a PC based frequency counter designed for maximum flexibility, ease of use and economy. It is an invaluable tool during design and debug of digital circuits and can be used to quickly to verify generated frequencies, pulse widths and duty cycles.
|
|
Memory Card Explorer ("MCE" & "MCE/NT") is a graphical Windows software package which provides direct access to the data stored in flash, SRAM and ATA PCMCIA memory PC Cards. It allows the binary "image" of the card data to be saved to or loaded from the hard disk drive in simple and fast operations. Data between any two address blocks can be copied and edited.
The format of the data on the card is unimportant - it could be a TFFS style format, or it could be a proprietary format written by a logger or portable instrument, or it could contain a mixture of formats. In all cases MCE can access the data. Also included is a card viewer that allows direct hex display of the data on the card.
|
|
The TCIC is Low cost high speed 8 channels thermocouple measurement interface board with USB and RS-232/485 interface. The TCIC supports thermocouple types J,K,E,R,S,T or ±500 millivolts at 1 microvolt resolution.
Main features:
On board cold junction compensation
On board temperature conversion functions enable stand-alone operation
USB interface as standard or USB + RS-232 /RS-485 (option)
Multiple boards may be connected via USB or RS485
8 opto-isolated outputs configurable as setpoints, latching alarms or user outputs
Comes with very useful software package and data logger
|
|
|
|
|
|
Key features
- Available as Starter kit
- Strain gauge, Pt-100 and potentiometric sensors
- CAN Interface
- 18 Bit A/D converter resolution
- Up to 5 Km cable
- Selectable bus-speed
- Daisy chain upto 60 devices
There is an increasing tendency to investigate the behaviour of large constructions under varying load conditions. Examples are: bridges, wind turbines, tower cranes, etc. Usually it is quite inconvenient to apply half- or full straingauge bridges onto such constructions, for which reason mostly single (1/4 bridge) gauges are utilized. This, however, usually implies cumbersome wiring to the inputs of the (remote) measuring amplifiers.
StrainBUSter has been developed to solve these problems by placing the measuring circuit in the direct vicinity of each point of measurement. Here all signal conditioning is done, after which all measured values are being transmitted via a CAN bus to one convenient central place, thus building one decentralized system. In this way, up to 120 measured values can be transmitted very reliably over longer distances.
Each StrainBUSter module has 2 separate input channels. The single straingauge, or the Pt100 sensor, is connected through a 3-wire connection, eliminating cable losses at the input side.
|
|
|
|