With new technology
The LDO oxygen probe and the pHD sc pH probe stand for superior technology. The LDO-Sensor determines the dissolved oxygen with an optical method, no more replacing of electrolyte or calibration. No electrode poisoning can occur because of the closed pHD sensor design. Less work and a longer service life in combination with gerater reliabilty translate into lower operating costs and appreciably more process dependabilty.
Wide range of applications
HACH LANGE probes can be installed in tanks, pipes or in bypasses - suitable mounting devices are available for every application.
By the application-specific design the probes can be exposed to aggressive fluids or high pressures.
The electrodes are kept separate from the sensitive digital electronics in an enclosure made of resistant plastic.
|
|
|
|
|
|
The Neutronics Model HI-3000 Halon Identifier analyzes liquid samples of Halon 1301 taken from storage cylinders. The instrument displays the percentage purity of the Halon 1301 and identifies and displays percentages of the most likely contaminants: Halon 1211, R12, R22, and R134a. By correctly identifying the contents of Halon 1301 storage cylinders, contamination of expensive Halon 1301 can be eliminated.
Easy to Use
Model HI-3000 has five modes of operation: WARM UP, READY, SAMPLE, IDENTIFICATION, and PURGE. A series of LED lights guides the user through a simple operating procedure.
During the WARM UP mode, the system is purged with air and is auto calibrated. When the unit displays READY, the identifier is prepared for the test.
In the SAMPLE mode, a sample is drawn from the cylinder. The next step, IDENTIFICATION, analyzes the gas and displays the results. During the IDENTIFICATION mode, a printer can be attached to provide hard copy printout for records keeping and cylinder certification.
In the final PURGE mode, the HI-3000 automatically calibrates itself and returns to the READY mode.
|
|
|
One cost-effective and convenient way to measure multiple parameters without the need to purchase many different meters is to make use of a multi-parameter meter. Most of these meters are able to measure 2 or more parameters. The models featured here measure pH, conductivity and dissolved oxygen.
|
|
|
|
|
|
The HI 9828 Multiparameter Portable Meter is a comprehensive analytical instrument, capable of measuring up to 13 critical water quality parameters (6 measured and 7 calculated), including pH, EC/TDS, ORP, DO, atmospheric pressure, and temperature. Some of the most advanced capabilities available are incorporated into this portable meter. Designed for intuitive operation, the menu-driven navigation is user-friendly and logical.
Engineered with smart features such as auto recognition of pH/ORP probe, auto-ranging adjustments for EC/TDS readings, and measurement check - to eliminate erroneous readings - and more, our design acually simplifies operations and handling. There is virtually no learning curve to getting into this meter and quickly mastering it's capabilities. For field applications, Hanna's Quick Calibration allows the user to standardize pH, conductivity and dissolved oxygen, all with one solution! While in calibration mode, the meter will also assess and verify probe functionality. For monitoring and recording data, HI 9828 can be equipped with Hanna's optional T.I.S. - Tag Identification System: iButton©s with unique ID numbers. Installed at any sampling site, these tags will record and match specific location information with logging data. Comprehensive GLP features, such as last calibration date and status information, calibration time-out, and date and time tags associated with sample measurements, ensure consistency and accountability. The LOGGER function memorizes data from each connected sensors and log-on-demand & automatic logging can record up to 60,000 data samples. All data is downloadable to a PC via USB connectivity.
|
|
This range of small probes with 3 mini-sensors measure pH, ORP, conductivity, temperature DO and level in wastewater, natural water and underground water. These SDI-12 ultra low comsuption probes can be connected to all SDI-12 systems
Using AQUA, AQUA 10 or AQUA 50 probes allows you to measure up to 6 parameters simultaneously: Temperature, Conductivity, pH, ORP, Dissolved Oxygen and Depth.
- Fast connection to ISCO devices, ADCON remote systems or any other instruments using the SDI12 protocol
- Ultra low consumption (40 µA)
- Connection of the sensors by simple "clip"
- Pocket size for maximum user convenience (length = 420 mm, diameter = 40 mm)
- Flexibility in use : its independent connection cable length allows adjusting cable length according to your needs
3 probes are available :
- AQUA : Wastewater
- AQUA 10 : Surface water (0-10 m),
- AQUA 50 : Underground water (0-50 m).
|
|
Conductivity
Honeywell conductivity technology helps measure, analyze and transmit valuable conductivity, resistivity and concentration information in simple and complex industrial processes with a complete line of analyzers, transmitters and conductivity cells.
Dissolved Oxygen
A complete line of analyzers, transmitters and dissolved oxygen probes ensures highly accurate, stable and trouble-free measurement in all types of applications.
pH-ORP
Patented non-glass Durafet probes and traditional glass pH technology help measure, analyze and transmit pH and ORP information in industrial processes. Honeywell provides a complete line of analyzers and transmitters, and several mounting types.
|
|
|
|
|
|
pH-ORP
Patented non-glass Durafet probes and traditional glass pH technology help measure, analyze and transmit pH and ORP information in industrial processes. Honeywell provides a complete line of analyzers and transmitters, and several mounting types.
7758/7758D Pipeline Mounting
The 7758 pipeline electrode mounting uses a stainless steel or polypropylene bushing with 3/4" NPT for mounting in pipelines.
7773/7773D Flow & Immersion Mounting
7773 mounting capabilities encompass the industrial measurements of pH, ORP, specific ion and temperature in a flow or submersion configuration.
7774/7774D Insertion Removal Mounting
The 7774 insertion/removal assemblies, which accommodate Durafet II and Meredian series combination (single-probe) pH or ORP electrodes, are designed for use in processes under pressure because the electrode can be inserted or removed without interrupting the process.
7777/7777D Immersion/In-Line Glass Mounting
Honeywell's 7777 series of electrode mountings enables users to interface Durafet II pH electrodes with a process via a ¾" threaded connection and Meredian II by either submersing the electrode or mounting it into a ¾" threaded connection.
7777DVP Immersion/In-Line Mounting
Honeywell's 7777DVP Series of electrode mountings enables users to interface Durafet III pH electrodes to a process via a ¾" threaded connection by either submersing the electrode or mounting it into a ¾" threaded connection.
7794DVP Sanitary Durafet III Mounting
The Sanitary Durafet III pH electrode has an integral, tri-clamp flange for easy mounting in the process.
HB Series Ruggedized Electrodes
Honeywell's HB Series of electrode mountings are designed for high temperature, high pressure and harsh chemical applications.
Transmitter - APT2000PH
The APT2000PH transmitter is a two-wire 24-volt device that continuously measures pH or ORP in industrial processes.
Analyzer - APT4000PH
The APT4000 pH/ORP analyzer continuously measures pH or ORP in industrial processes.
DirectLine DL421 pH Transmitter
The DL421 transmitter can be connected directly to the electrode as one integral mounted unit. Alternatively, the transmitter can be wall, pipe or DIN rail mounted remotely from the associated pH electrode.
DirectLine DL422 ORP Transmitter
The Meredian II ORP electrode can be located directly on to the DL422 transmitter module as one integral mounted unit. Alternatively the DL422 transmitter can be wall, pipe or DIN rail mounted remotely from the ORP electrode.
DirectLine DL1000 Durafet Mountings
DL1000 pH electrode in combination with DL421 pH transmitter either directly or remotely mounted offer an ideal end user solution to online pH measurement. Installation, maintenance and performance cost savings are assured.
DirectLine DL2000 Meredian Glass Mountings
For pH measurement the DirectLine transmitter modules can be mounted integrally or remotely with the DL2000 Meredian glass pH electrode.
DirectLine DL3000 ORP Mountings
For ORP measurement the DirectLine transmitter modules can be mounted integrally or remotely with the DL3000 ORP electrode.
Durafet non-Glass pH Sensor
The Durafet pH electrode is an industrial, non-glass, unbreakable, Ion Sensitive Field Effect Transistor (ISFET)-based pH sensor that provides fast, accurate and dependable pH measurement in the most demanding applications.
HPW7000 HiPurity pH Measurement System
The HPW7000 HiPurity Water pH Measurement System is an electrode mounting assembly designed specifically for the difficult pH measurement in high-purity water applications.
TL1000 Durafet II Twist Lock Mounting
The TL1000 Series, Twist Lock Mounting, provides an easy way to install/remove Durafet III pH electrodes from pipelines and tees. A quick ¼ turn is all that is required for installation/removal.
Analyzer - UDA2182 Multiple Input
The UDA2182 Universal Dual Analyzer represents the latest in analyzer technology by providing the most versatile multiple-input analyzer package on the market for measurement of pH, ORP, conductivity and dissolved oxygen.
|
|
Multifunctional Particle Counting System for Liquids
Mobile System for Particle Counting Filtertest
and Cleaning Control PAMAS 3108 FM
Portable integrated system with sensor and sampling system
- Compact analysing System for liquids:
Water, drinking water and organic fluids
- Utmost repeatability and accuracy
- Size range: 1 – 200 µm:
calibration according to ANSI/NFPA T2.9.6R1-1990, ASTM F 658-80
- Software in English, German, French, Polish, Finnish and Spanish
- Pressureless sampling as well as under pressure up to 210 (420) bar
- Viscosity independent up to 160 cStokes
(pressurized sampling up to 300 cStokes)
Remote control with PAMAS PMA program
- Automatic storage and documentation in readable format
- Classification of particle number and size within the sensor size ranges
- highest flexibility
- Printout including all sample parameters, numerical and graphical
presentation and all main cleanliness classes
|
|
| ... products without technical information |
| |