CONDENSATE CLEANER ACR 1
With activated carbon coalescense filter
Specs Compressor capacity (HP, max.) 15
Condensate connection (input, '') 3 x 1/2
Water connection (output, ") 1 x 3/4
Working temperature (min./max., ºC) 5 - 60
Dimensions (l x w x h, cm) 45 x 28 x 21
Weight (kg) 4.3
|
|
|
To improve the operating efficiency of pneumatic equipment, Kadant Johnson air separators eliminate 99% of entrained contaminants including moisture, pipe scale, dirt and oil. When used on steam service, Johnson separators provide cleaner, drier steam to heat exchangers, steam turbines and other processing equipment that requires clean dry steam.
|
|
FSX SOLUTIONS - Engineered Flanged Filters
Features:
* Coalescing, particulate and hydrocarbon filtration
* Standard flows up to 17,000 SCFM
* Standard flanged connections from 2" to 12"
* Standard and customized models available
* ASME and CRN
Standard models:
* 2" to 12" flanged connections
* Free Standing XZ Series or Inline XT Series Filter
* Stainless steel internal parts for maintenance-free operation
* Differential pressure indicator
* Corrosion allowance
* Automatic Float Drain
Customized models:
* Larger flows/higher pressures
* Stainless steel construction
* Vacuum applications
* Electronic drains
* Activated carbon tower
* Certifications:
Lloyd's Register, ABS, CNR, CPV
|
|
|
AFW large capacity compressed air filters and centrifugal water separators ensure high quality compressed air, which is essential to pneumatic and automation systems. Correct air preparation minimizes component failure, increases the operating life of equipment and reduces energy consumption. Filters and separators are suitable for use with mineral and synthetic oils, plus oil-free compressed air applications. Depending on the model, flow capacities are available from 475 to 16100 CFM.
|
|
Remove bulk water from your compressed air or gas system
Bulk water, which exists in air or compressed gas systems, causes corrosion of piping, damage to valves, cylinders, pneumatic tools and machinery, and reduces the effectiveness of aftercoolers/heat exchangers. Over 99% of bulk water can be easily and economically removed by installing a type XWS Water Separator. Your compressed air and gas system will operate much more efficiently with reduced downtime and maintenance costs. This upgrade will also improve the effectiveness of aftercoolers, refrigerant dryers, filters and other downstream equipment.
Options:
* Automatic float drain
* External electronic drain
* High pressure versions
* Stainless steel construction
|
|
|
|
|
|
EPG's CS-16b Condensate Separator
Since 1988, EPG Companies Inc. has built hundreds of its CS series condensate coalescer separator filter silencers for removal of both particulates and liquid droplets from air streams. Its unique up-flow design passes the air stream through a mixed media element which coalesces fine liquid vapor into larger droplets which, by gravity, drop to the bottom of the sump. Those droplets which are too small to overcome the velocity of the air stream are trapped in the separator layers of the media until they become large enough to drop out of the air stream at an efficiency of 99%. As the liquid droplets fall back down through the media pack, they tend to wash particulate matter out of the five (5) micron filter media carrying the particulates down to the sump. Inlet sound levels are absorbed in the CS vessel by change in velocity, direction and recovery trumpet. Typical sound reduction is 8 to 12 dBA. By design, the vessel including media has a pressure drop of only 1 /2" W.C. at maximum air flow. This equates to more energy available for the system.
- 16" diameter, 40 1 /2" high with mounting feet
- Inlet and outlet ports are 4 1 /2" diameter
- Dry weight of the vessel is 130 pounds
- Fifteen (15) gallon sump capacity
- Hot dipped galvanized coated steel
- Access ports for sampling and sensors
- Easy to remove media for cleaning or replacement
- Flow up to 350 SCFM
- Vacuum to 16" HG
|
|
FEATURES
- Cast Construction
- High Efficiency Over Wide Flow Range
- No Required Maintenance
- Economical Choice for Most Applications
- Removes 99% of Liquid and Solid Entrainment
Particles Larger Than 10 Micron
- Gas, Steam or Air Applications
OPTIONS
- Integral Trap
- Trap Heating Element
- ASME UM or U Code Stamp
- Water Gauge Tap
- Thermometer Tap
- Larger Drain Size
|
|
Compressed air is a dependable, flexible and safe energy source. however, the air must be treated before use to ensure that the pneumatic tools last well and works reliably.
An extensive range of filters, regulators, lubricators, pressure gauges, micro-filters, drains, separators and dryers provide solutions for all issues associated with polluants in air pipes.
|
|
Separators
Used to remove condensate and/or suspension droplets, as well as other impure substances in installations of steam, compressed air or other gases.
Moisture separators allow dry steam and compressed air, avoiding or preventing the wear of tools and pneumatic equipment, respectively.
|
|
Air Cleaners / Housings
Donaldson recommends the use of our housings with RadialSeal%u2122 sealing technology for compressors. Our FPG style housings are ideal because they%u2019re reliable, durable, plastic and easy to service. Many air cleaners are stock product, but custom design support is also available.
|
|
This after-filter retains polluting particles thanks to the following main filtration effects: diffusion, inertia and direct interception.
It is recommended for those machining processes producing fine mists from soluble oil mixed with dusts (especially of conducting materials: e.g. cast iron processes, pressure die-casting etc.).
Our after-filter is available in various models with two different levels of efficiency:
EU9 and EU13. The last one is able to retain also some smokes.
The fibreglass after-filter can be used in combination with the three kinds of air filters (turbine single and double centrifuge) and with all our modular filtration units.
|
|
|
|
|
|
* Modular design provides optimum field flexibility and short manufacturing lead time - have it your way fast!
* Heavy duty carbon steel construction for long life - Module constructed of 7 gauge carbon steel. Door, hopper, inlet and panels are all 10 gauge steel.
* Baked on, durable alligator green powder coat paint - All carbon steel components are 5-stage acid washed prior to powder coating for maximum paint adhesion. Painted inside and outside for unsurpassed weather and corrosion resistance.
* Vertical design of the Farr filter cartridges provides more efficient pulsing of dust, thus eliminating uneven dust loading associated with horizontally mounted cartridges.
* High entry cross flow inlet eliminates upward can velocities associated with traditional hopper inlets. The channel baffles installed in the inlet protect the filters from incoming dust and separate the larger particles directly into the hopper, reducing the load on the filters.
* The Gold Series utilizes Gold Cone® cartridge technology to deliver clean air and long life while utilizing the smallest floor space of any dust collector available today.
* Multiple filter media and pleat spacing options are available to best suit your specific application and dust.
|
|
After compressing the air, the concentration of particles and moisture increases. This creates an abrasive mixture that can cause extensive damage.
Instruments and tools can malfunction, spray painting and breathing air can be rendered unusable, maintenance costs will increase and products will be spoiled.
The range of Atlas Copco's DD - PD - DDp and QD filters, when used in the correct combinations, will provide high quality air from 9 to 7200 l/s at nominal working conditions.
|
|
HD High Pressure Filters
HD high pressure filter housings are designed for compressed air and gas applications up to 400 bar. Each housing can accommodate any of our standard range of filter elements for your specific need. Flow capacities from 30 to 720 m³/h nominal at 7 bar g are available. Modifications on request.
|
|
|
A range extended for the air conditioning: AS2 - AS3 - AS5 complete Unit FRL, governor automatically-controlled, filters, membrane drier, pressurization progressive, gate valve. Flow from 150 to 10.500 possible Nl/min. Many accessories for all applications
|
|
Sample Gas Filters
The distance between the extraction point of sample gas and the analyser cabinet is normally bridged by tubes or hoses in continuous emission monitoring (CEM) systems. Depending on the method of analysis (FDIR, HFID, hot wet analysis, total hydrocarbons, etc.), these gas lines can be unheated or must be heated to prevent unwanted condensate formation.
Due to the nature of such installations, additional in-line filtration is required.
Bühler offers a wide selection of unheated and heated filters specifically designed for gas sampling applications.
|
|
Large Flow Filtration for Air and Gas (1,600 scfm and larger)
Fabricated from high-quality carbon steel, PCC Series Filters are welded to ASME standards to provide large flow applications with exceptional air quality and low pressure drop. Designed specifically for use with our high performance air and gas filter cartridges, these filters can be used alone or as prefilters and afterfilters. D urable and dependable, PCC Series protects your compressed air and gas system and enhances dryer performance.
Flanged lid allows easy filter cartridge access. No need to disconnect drain valve or other tubing when changing cartridges
Sturdy vessel support legs simplify piping installations
Multi-element, carbon steel housing design 1,600 to 15,000 scfm
Easy to read differential pressure gauge standard on all models
Low housing pressure drop saves dollars (1 psi pressure drop costs, on average, $67 per year per 100 scfm at 6¢ per kWh).
|
|
The equipment made by LTA Industrial Air Cleaning can be divided into four main categories.
Source extraction:
contaminated air is extracted right at the source and cleaned.
Group extraction:
contaminated air from a group of machines is collected and cleaned locally.
Central exhaustion:
air to be cleaned is collected by a duct system, cleaned in a central system, and exhausted.
Industrial room air cleaning:
when operating open machines or to meet strict regulations on air purity, building air cleaning can be used.
Further differentiation of the precipitation types is possible between electrostatic or solid media filtration.
|
|
Vertical or Horizontal constructions mounted on legs or skirts.
Designed to international Pressure Vessel Codes and Standards.
These filters have multiple cartridges securely mounted with the vessel.
Cartridges offered can be of various types of construction depending on the application i.e. Pleated, wound or all metal construction.
Access to the internals can be via a Quick Opening Closure or Bolted Cover.
Flow passes through the cartridges in an in - to out flow direction.
We are able to offer elements that will accept a high differential pressure before mechanical damage can occur.
|
|
The G•ONE can be used for water based coolants (emulsions) and straight oils for low to medium loads of oil-mist. It is not suitable for any smoke collection. Typical operations are:
• Driling
• Turning
• Miling
• CNC operations
|
|
The subminiature filters are ideal for a broad range of industrial, medical, and instrumentation applications. The disposable filters are designed to remove most particulate contaminants in compressed air systems. The filter media, a Dutch Weave 316 stainless steel screen, is available in 5, 25,43, and 73 microns. The maximum supply pressure is 125 PSI.
Three models are available: The F-950 Series Filter has barbs for 1/16” or 1/8” I.D. tubing. The F-960 Series Filter is encased in a 10-32 UNF male threaded housing with a barb for 1/16” or 1/8” I.D. tubing. The F-970 Series Filter has the largest effective filter area and is encased in a 10-32 UNF female threaded housing.
|
|
Features:
- Integrated monitoring of the useful lifetime of the filter element to automatically indicate the optimal time of element change
- Easily readable, informative display
- Potential free contact for relaying a fault signal to a control centre
- Condensate discharge at the rear through elbow connector, ideal for installation close to a wall
|
|
Compressed Air Filter
Sizes Available: Miniature Series 1/8", 1/4" NPT, Compact Series 1/4", 3/8", 1/2" NPT, Large Series 1", 1-1/2" NPT
General purpose filter removes water, dirt and dust from the air line.
Manual and Automatic drain types available. The automatic drain operates only when flow change occurs.
Bowl available in transparent polycarbonate or metal zinc die cast.
Filter Element size: Miniature: 5, 25, 100 micron, Compact: 5, 25, 50 micron, Large: 5, 50 micron
|
|
|
As the world’s leading air treatment technology company, Ingersoll Rand set out to find a better way. The solution: re-defining compressor air filter performance and maintenance using proactive time-based element replacement. Ingersoll Rand’s next generation of compressed air filters features our new Element Replacement Indicator (ERI) –an illuminating approach to filter maintenance that yields real, measurable benefits for you, for your company and for our environment.
|
|
Compressed air has many advantages in terms of safety, flexibility and economic use. However, more stringent requirements are continuously being made on the quality of compressed air Airpress compressed air filters are deliverable for many
applications, are easily maintained and are fitted with a differential pressure guage.
This allows easy evaluation of the filter quality and therefore the correct moment to replace the element. The compressed air filters are housed in an aluminium casing with a plastic coating. All filters are provided with an automatic condensate/oil valve, which can also be operated manually. The filters are designed for an operating pressure of 16 bar (Spare element = Item number/E)
|
|
Air treatment system: filter, regulator, lubricator
- A modular, compact range for all types of pneumatic circuits
- Quick mounting and connection on installation: filter, regulator and lubricator functions in a "single unit"
- Lightweight and robust for direct fitting on rigid conduits
Accessories: Softstarter cut-off valves, padlockable manual isolating valves, bypass modules.
|
|
CFF Series Filters 1942
Quality is Built into Every Housing
* Epoxy coated interior and exterior heads and bowls
* Threaded condensate discharge connection
* Bayonet head to bowl connection up to 170 scfm (289 m3/h)
* Thermoset polyurethane liquid level indicator
* Every housing tested to a 5:1 factor of safety
Quality is Built into Every Filter Element
* All stainless steel inner and outer cores
* Complete seam welded cores having a burst pressure of 65 psid (4.5 bar)
* Coated foam sleeves providing protection against chemical attacks
* 100% silicone free
|
|
General Description
316 stainless steel filter for filtration of compressed air in the offshore, food, pharmaceutical and allied industries. Large 40 micron standard element with manual or automatic drain for the removal of liquids and solids.
- Large flow paths minimise pressure drop. 316 Stainless steel throughout.
- Large stainless steel element.
Operating Fluids
- Gases, air, inert gas, sweet (natural) and sour gases.
- Ingress protection Heavy seas / on deck rating
Technical Data
Working Temperature:
- Ambient temperature -20ºC to +80ºC (-4ºF to +176ºF)
- Low temperature version -50ºC ( -58ºF)
Ports:
- 1/4", 1/2", 3/4" and 1" NPT and BSP
|
|
|
Fisher Controls, Regulator Division is requesting the return of regulators per the July 10, 2007 IMPORTANT SAFETY NOTICE--REGULATOR RETURN. The regulators to be returned are the Type/Series HSR, 67C, 67CR, 67CF, 67CFR, and R622.
|
|
General Description
316 stainless steel for the offshore, food, pharmaceutical and allied industries. A combination unit for filtration and pressure regulation of compressed air for use in these industries.
- 316 Stainless steel throughout. Large flow paths minimise pressure drop. Integral mounting holes.
- Tagging facility built in.
- Filter Unit
Operating Fluids:
- Gases
Filtered lubricated or non-lubricated air, inert gas, sweet (natural) gases. Sour gas option available
- Liquids
Low pressure hydraulic, mineral oil or water.
|
|
|
|