High tech and sturdy air operated valve, with a floating
plug seal, meeting stringent use criteria.
An extra thick body of the actuator and of the valve, ensuring a good resistance to mechanical and thermal distorsions.
A modular design enabling the following configurations:
Shut off valve DCX3 L
DCX3 T
DCX3 X
Divert valve DCX4 L/L
DCX4 T/L
DCX4 L/T
DCX4 L/X
PFA seals quality ensures a complete sealing at high temperature and a good resistance to aggressive products.
Plastomer seal can be replaced by elastomer seal
Single or double acting connection
With plastomer seal, vertical setting up (especially for DCX4)
Dimensions 1” - 1-1/2” - 2” - 2-1/2” - 3” - 4” - 5” - 6” Material
Body: 316L stainless steel
Shut-off unit: 316L stainless steel
Manual or automatic operating devices: 304 stainless steel
Plug seal: PFA and elastomer
Stem seal: viton, EPDM, silicone
Options
• Signal back equipment on the top of the actuator
• Sterilization of the stem through an upper guide bearing
• External = 47 RA max (150 grit)
• Internal = 32 RA max (180 grit)
Upgraded finishes upon request:
Surface Finish
Variants
Plug and body machined for a metal to metal sealing (without seal)
Elastomer sealing (specific plug with viton, EPDM o-ring)
Manual operator device (instead of the actuator
Tank bottom type
Long stroke valve available upon request |
|
MODELS :
V2FIC02 Mounting (subplate)
V2FIC03 Mounting (subplate)
SIZES : 3/8 " TO 3/4"
Max. Pressure : 500 psi(350 bar)
FLOWS : 13 - 29 gpm / 50 - 110 lpm |
|
Connection guaranteed: a wide range of functions and variants - always harmonised to the respective requirements.
• Exhaust air/supply air flow control or without non-return function
• Flow rate 15 ... 4,300 l/min
• Threaded connectors M3 ... G3/4
• Push-in fittings QS3 ... QS 12 or PK-3 ... PK-6
• Variants with increased corrosion resistance
|
|
The miniature Preset Flow Control is ideal for many applications involving pneumatic systems, including the control of cylinder speed.
The operation of the flow control is based on the movement of a small disc. The flat surface on one side of the orificed disc seals and permits flow through the orifice. The amount of flow permitted in the reverse direction is determined by the orifice size. In the forward direction full flow is permitted. The flow controls design allows a maximum supply pressure of 75 PSI with a minimum cracking pressure of less than 10” H2O. Orifice sizes are available from .004” to .040”. |
|
Types:
P.C. Flow Regulator
P.C. Flow Control
Priority Style P.C. Flow Regulator
Compensator Valves |
|
| B&G Flo-Control Valves are used for preventing gravity flow in forced water systems and to permit summer-winter operation of indirect water heaters. Flo-Control Valves in NPT sizes ¾" to 2" are made in combination straight-angle patterns permitting installation in either horizontal or vertical pipe lines. Larger sizes may be furnished in either straight or angle patterns. Removeable top cap allows easy cleaning and service without removing pipe connections. Manual operating position for vertical lift disc to permit gravity circulation. |
|
| A family of in-line composite body flow controls, needle valves, and check valves that are tough and corrision resistant. Four stage, tapered needle design provides infinite control. Tamper resistant locking ring prevents unwanted adjustments to the valves. These can be used in-line or be panel mounted. ARO's 360 degree Swivel Right Angle Flow Controls are ready for installation on all ARO Cylinders. |
|
Designed to precisely control the flow of adhesives and sealants during automated dispensing applications, this compact and lightweight valve mounts easily onto either the end of a robot arm or an XY table.
|
|
KOFLOC 2203
The KOFLOC Variable Secondary Pressure Flow Controller Valve MODEL 2203 SERIES is a control valve for precise control of minute gas flow and maintaining constant flow under fluctuating secondary pressure (outlet), provided the supply pressure remains constant. This characteristic makes it a must-have preliminary valve in many flow control mechanisms. Constructed using high precision parts, the design of the MODEL 2203 SERIES transforms the rotation of the regulating screw to into linear motion of the needle without subjecting it to gaps and vibrations produced by the screw, to ensure stable and even control of minute flow.
FEATURES
♦ Excellent flow stabilization
♦ Clean construction
♦ Independent from secondary pressure fluctuations
APPLICATIONS
♦ Gas chromatography
♦ Environmental analysis
♦ Atomic absorption spectrometry
♦ Gas mixing
♦ R&D
♦ General industrial use |
|
KOFLOC 2412/2412M
The KOFLOC Precision Needle Valve MODEL 2412 SERIES is designed to control minute flows with precision and ease, controlling minute flow stably and accurately, as low as 0.5 ML/MIN. It has been widely used in numerous applications from general industrial applications to analytical equipment such as AAS (Atomic absorption spectrometer). The needle orifice of the MODEL 2412 SERIES has a temperature compensating structure (US P.A.F.) achieving the characteristic of 0.3%/˚C for gas temperatures between 15 ˚C to 35˚C. MODEL 2412 SERIES includes 15 different needle valves to offer optimum flow control corresponding to various flow levels MODEL 2412M SERIES with Multi-Dial is a precision needle valve with a radial gauge to give simple means to approximate flow volume
FEATURES
♦ Accurate control of minute flow
♦ Wide needle variation
♦ Non-rotating needle
♦ Wide operating temperature range
APPLICATIONS
♦ Atomic absorption spectrometer
♦ Burn control
♦ Research and development
♦ Air sampler
♦ Filter testing
♦ Burn control
(2412M)
♦ Can be used as a substitute for a flowmeter
♦ Detection of flow pass resistance fluctuations |
|
The EL-PRESS series digital electronic Pressure Meters and Controllers have a well-proven compact thru-flow design and are available in pressure ranges from 2-100 mbar up to 8-400 bar, both in absolute and relative (gauge) pressure. A differential pressure transducer can also be supplied in the ranges of 2-100 mbar up to 0,3-15 bar. The pressure controller performs with high accuracy and repeatability and should be specified for forward or backward pressure control. Todays EL-PRESS series are equipped with a diaphragm type piezoresistive pressure sensor and a digital pc-board as standard and offer high accuracy, stability and reliability. The basic digital pc-board contains all of the general functions needed for measurement and control. In addition to the standard RS232 output, the instruments also offer analog I/O. As an option, an integrated interface board provides DeviceNet, PROFIBUS-DP, Modbus-RTU or
FLOW-BUS protocols. |
|
| A diverse range of regulators provide precise control to the inlet of the regulator and act as a precision relief valve. Products include both diaphragm and piston sensed designs with pressure control ranges from 10psi to 6000psi for use on liquid and gas applications. |
|
26-1700 Series: Versatile
Extremely sensitive
Ideal for both gas & liquid service
High temperature versions available
Accuracy: ±1% of relief pressure range
26-2300 Series: High Accuracy
Precise pressure control
Diaphragm sensed - highly sensitive
Crack to reseat: 2% of set pressure
Bubble-tight shutoff at all reseating pressures
26-2500 Series: High Flow
Large diaphragm for excellent sensitivity
Bubble-tight shutoff at all reseating pressures
1/2", 3/4" and 1" NPT inlet and outlet port sizes
26-2900 Series: Tracking
High Flow
Negative spring bias
Designed for BIBS application
Diaphragm sensed - highly sensitive
44-2300 Series: Economical
Hand adjustable
Diaphragm sensed
Dome loaded
Four relief pressure ranges
44-4700 Series: Sub-atmospheric
Metal to metal diaphragm assures minimum inboard/outboard leakage
Controls sub-atmospheric to positive pressures
High flow capacity
Negative spring bias |
|
44-2200 Series: General Purpose/Compact-Reducing
1/4" inlet and outlet ports
Diaphragm sensed - highly sensitive
Various trim options available
44-2600 Series: General Purpose/Large Diaphragm
Increased sensitivity, minimal droop
Repeatability: ±1/2% of outlet pressure range
Accuracy: ±1% of outlet pressure
44-2800 Series: Accurate/Positive Seal-Reducing
Mechanical link between diaphragm & main valve prevents pressure creep
Positionable captured vent bonnet
44-3400 Series: Two Stage-Reducing
Decaying inlet characteristic: .04 per 100 PSIG inlet pressure change
Various trim options available |
|
26-1100 Series: High Flow Cv=1.3 or .46 - Reducing
Diaphragm sensed - highly sensitive
Modular construction - easy service
External sensing available for improved accuracy
Balanced main valve increases seat life
26-1200 Series: High Flow Cv=3.3 - Reducing
Similar to 26-1100 with higher flow capacity
44-4200 Series: Economical
Dome loaded
Piston sensed - highly reliable
Compatible with TESCOM electronic pressure controllers |
|
VAV control, actuators and differential sensors, explosion proof
Electrical, explosion proof quarter turn actuators series ExMax and RedMax, for VAV dampers, from 5 Nm to 100 Nm, in acc. with ATEX 94/9/EG for installation in hazardous areas zone 1, 2, 21 and 22, for all kind of gas, vapours, mixtures and dust. Actuators with or without fail safe spring return function. 24 to 230 VAC/DC multivoltage supply, 5 motor running times adjustable on site, on-off, 3-pos, 0...10 VDC, 4...20 mA mode, 100 % overload protected, robust aluminium housing with IP 66 protection, optional stainless steel version, integrated heater for use from -40°C to +40°C/+50°C, cable connection, approx. 1 m cable, manual override, squared shaft connection 12x12 mm (size S) and 16x16 mm (size M). series ExMax-... for use in zone 1, 2, 21 and 22. series RedMax-... for use in zone 2 and 22. Optional accessories like external adaptable aux. switches, terminal boxes and mounting brackets available.
Differentail pressure sensor series ExCon-P and RedCon-P, in acc. with ATEX 94/9/EG for installation in hazardous areas zone 1, 2, 21 and 22, for all kind of gas, vapours, mixtures and dust. 24 VAC/DC supply, measuring ranges +/- 100 Pa, +/- 250 Pa,+/- 600 Pa,+/- 1250 Pa,+/- 2500 Pa,+/- 5000 Pa, +/- 7500 Pa. series ExCon-P for use in zone 1, 2, 21, 22. series RedCon-P for use in zone 2, 22. |
|
| Variable Flow Control Valves maintain the flow rate of hydraulic fluid to a selected value. Applications include hydraulic cylinders requiring constant extension or retraction speeds and hydraulic motors requiring constant rotational speeds. When used with a fixed delivery pump the excess flow is By-Passed across a relief valve. |
|
20-1000 Series: Compressed Natural Gas
Balanced main valve minimizes inlet pressure fluctuations
Piston sensed – highly reliable
Water heat jacket standard
20-1200 Series: High Pressure Hydrogen
Nickel-plated aluminum
Large piston sensor
All regulators tamper-proof
20-1400 Series: High Flow / Low Pressure
Diaphragm sensed – highly sensitive
Dome load spring bias ± 2 PSIG
Captured bonnet design for safety
44-6000 Series: In-Line High Pressure
Balanced main valve design
Positive shutoff seal
Captured bonnet available
Patent pending
44-7400 Series: Pressure Reducing
Ideal for CNG dispensing applications
Several porting configurations available
Spring adjust, high outlet, high flow |
|
Air/gas ratio controls GIK
Governors for gas GDJ
Governors for gas J78R
Governors for gas VGBF
Safety overpressure slam shut valves JSAV
Safety relief valve VSBV
Speed and relief governors VAR, GAR
Variable air/gas ratio controls GIKH
|
|
The gas pressure regulators (RTP) are designed to reduce natural gas pressure from medium to low one, and to keep the gas pressure rate independent on input pressure and flow changes. The regulators are suitable for domestic as well as for industrial installations.
Description
Single stage
Single stage gas pressure regulators have diaphragm - spring single stage pressure regulator with the lever system control element.
Double stage
Double-stage gas pressure regulators have two stages of pressure reduction, both with diaphragm-spring control.
The RTP gas pressure regulators are equipped with the following safety devices:
* The over-pressure and under-pressure shut-off
* The relief valve
Our regulators meet requirements of standard EN 12 279
We are producing various versions and sizes, as an example we are presenting double stage regulator
RTP 10-M..-..
Technical data
Inlet pressure: 0,1 - 0,5 [MPa]
Adjusted output pressure: 2 [kPa]
Regulation deviation: ¡À0,1 [kPa]
Outlet pressure at no consumption: max 2,6 [kPa]
Safety pressure: 3 - 0,1 [kPa]
O.P.S.O.: 4,5 [kPa]
U.P.S.O.: 1 [kPa]
Volumetric flow: 10 [m3/h]
Volumetric flow: 10 [m3/h]
Relief valve size: Rp 3/8 [inch]
Weight: 1,12 [kg]
Ambient temperature range: -30 to +60 [¡ãC]
Response time: ¡Ü 5 [s] |
|
| An extensive range of pressure regulators in 316SS for controlling pressures from 1psi to 10,000psi. Our range covers sizes from 1/8" to 8" - covering products from gas cylinder regulators to Nitrogen blanketing applications. |
|
R230
high sensitivity
many options and pressure ranges, G1/4
outlet 0 - 0.15 / 28 bar, 900 l/min
|
|
44-2600 Series: General Purpose/Large Diaphragm
Increased sensitivity, minimal droop
Repeatability: ±1/2% of outlet pressure range
Accuracy: ±1% of outlet pressure
44-3200 Series: High Flow/Purge
Ideal purge regulator
High pressure inlet version incorporates a balanced main valve to minimize inlet pressure fluctuation
26-1500 Series: Sensitive/Non Venting-Reducing
Compact design
Elastomeric diaphragm - highly sensitive
Dome loading available
For liquid or gas service
26-1600 Series: Sensitive/Self Venting-Reducing
Elastomeric diaphragm - highly sensitive
Controls up to 500 PSIG
Dome loading available
For liquid or gas service
Works with TESCOM motorized actuator for remote control
DH Series: Low Pressure
Diaphragm sensed - highly sensitive
Excellent repeatability
Very high flows at low pressures |
|
Press Man is a simple but yet efficient controller for maintaing constant pressure in heating and ventilation environments. It is charactized by a very robust construction and extremely simple user interface.
Press Man controls the HVAC pressure from an pressure transmitter with an analog output mounted directly in the ventilation system. Difference pressures can be obtained by incorporating mecanical blends etc. IP54 grade and integrated keys / display makes Press Man well suited for many applications.
Press Man has a setpoint, which is controlled by the arrows. A single press will put the setpoint one up or down, holding the arrows will make the setting change fast while pressed. Measured pressure will be displayed pr. 5 sec after keys have been released
Press Man has two relay outputs, the first is used on ON/OFF by the key setting, the other is used for alarming. ON/OFF is activated as the key is activated, the alarm output will be active when the output can not be reached whithin 30 minutes !. Means, that if the output internally is UNDER or OVER the MIN/MAX settings, the relay will activate. Flashing LO or HIGH in display
Press Man can indicate the real output for the attached speed controller, OR, it can indicate the real input from the attached pressure transmitter. Both values will indicate in percentage (0-100) of input and output)
Press man can be 100% stopped, pressing the ON/OFF button. Display will indicate OFF and the DC output will be forced to 0, as will be the 2 relays. Press man has individual settings for minimum and maximum speed for the attached speed controller. Settings to be controlled by MIN/MAX buttons. Parameters for Proportional Band and Integration Time is done from the keypads as any other parameter. The PI regulator will meassure the pressure, compare it to the setpoint and try to maintain the dc output to make the real pressure as close to the setpoint as possible. |
|
|
|