|
|
Hale Floating Pumps
Hale's Fyr Flote and Super Chief pumps are designed especially for the fire services to be highly portable and easy to use. Able to draft in as little as four inches of water, they can be easily used with alternative water sources such as streams, lakes, or pools. They are designed for easy maintenance with a tough long lasting outer shell.
|
|
Pumped Liquid
For handling with non-aggressive or aggressive fluids, uncontaminated or loaded with solids, cold or hot liquids
Main Fields Of Application
Evaporation and crystallization plants, supply and circulating systems in all branches of industry, sewage and environmental engineering
|
|
| ... products without technical information |
| |
The Water Specialties Propeller Meter is the best choice for measuring clean water flows in municipal and industrial applications. The meter is engineered to deliver superior performance, low maintenance and unsurpassed durability. Meter materials and performance meet or exceed AWWA standard C704/92.
Water Specialties Propeller Meters are manufactured using precise techniques and high quality materials. For example, long-life ceramic thrust bearings and a cast bronze gearbox produce the best propeller meter available.
Measurement accuracy is +/- 2% of reading. The meter accommodates flow ranges from 35 GPM to 200,000 GPM. The Water Specialties Propeller Meter can be installed vertically, horizontally or inclined, with sizes ranging from 2" to 120".
Proven design for clean water flows
Quality construction
Long-life components
Meets/exceeds AWWA standard
Accuracy of +/-2% of reading
Wide flow range
|
|
|
|
|
|
McCrometer has set the standard for liquid flow measurement performance, ease-of-use and value in the agricultural and turf markets since 1955. Its leading-edge propeller flow meters offer economical and versatile flow measurement. The Mc Propeller is suited to dirty water flows, municipal and other high-volume water applications.
Unlike traditional propeller meters, the Mc Propeller uses a flexible drive-train and sealed ball bearings. A unique design makes it easy to service in the field and requires no external power or batteries. The Mc Propeller is designed to comply with AWWA standard No. C704/02. Standard features include an instantaneous flow rate indicator and six-digit totalizer.
There are no tight tolerances in the Mc Propeller. It handles solids suspended in water without clogging. With its high accuracy, this flow meter is also a water management tool, that reduces water costs, preventing over-irrigation and reduces leaching of chemicals and fertilizers into the ground.
Key features:
Best-selling irrigation meter in the US
Clean and dirty flows
Easy to install and operate
Easy to service in the field
Accuracy of +/-2% of reading
Repeatability of +/-0.25%
Self-cleaning design
Instantaneous flow rate Indicator-totalizer on every model
Flow range of up to 25:1
|
|
Axial turbine flowmeter for liquids Type FVA915VTH
For measuring the volume flow rate or for dosing tasks with
small flow rates.
Extraordinary compact design.
Wide, usable measuring range.
Various options for operation:
Cooling water flow, medical technology, plastics industry,
solar systems, baker's equipment, machine tools, catering
equipment, photographic laboratory equipment, dispensers,
dosing equipment, cooling equipment, heating applications,
calorimetry.
|
|
This competitively priced instrument (flowmeter - thermometer) has been developed for use under challenging circumstances. Because of its different impellers, you can use it to measure amost any liquid or gaseous medium.
Fields of application :
Measure rivers flows
Irrigation canals
Ocean flows
Air conditioning conduits
Sewage flows
Ventilation shafts
Hydrological studies
Aerological studies
Chimney flues
Spécifications Techniques :
FLOW SPEED MEASUREMENT
Units :
km/h, mph, knots, m/s and cm/s
Accuracy :
+/- 5 % from - 10° to + 50°C
Measuring range :
2 to 150km/h
TEMPERATURE
Units :
°C, °F and windchill
Accuracy :
+/- 1°
Functions :
Current, minimum, average, maximum temperature and windchill factor
|
|
ITT Flygt WC & YDD (Pewaukee US)
Technical features:
Design: Vertical turbine “pull out”
Size of outlet flange: according demand
Max. liquid temperature: according demand
Max. Flow: 90.000 m3/h
Pump sealing: Mech. seal or packing.
Max. Head: 25 m
Max. operating pressure: 10 bar
Shaft Impeller Column Pump seal
AISI 410 AISI 316 GG 25 Customer choice
Duplex Duplex or Super Duplex
ITT Vogel WM (Peewaukee US)
Technical features:
Design: Vertical turbine
Type of impeller: enclosed
Max. Flow: 60.000 m3/h
Max. Head: 175 m
Max. operating pressure: 25 bar
Shaft Impeller Column Pump seal
AISI 410 AISI 316 GG 25 Customer choice
Duplex Duplex Duplex
Super Duplex Super Duplex Super Duplex
|
|
| ... products without technical information |
| |
AvK RANGE
AvK - generators, reliable in service on all continents
On land in stationary plants as well as in mobile applications such as railway vehicles and cranes.
On sea on board of ships and on offshore oil platforms.
There is a wide variety of applications:
continuous power supply in isolated operation or running in parallel with the mains peak load
mains peak load operation in parallel with the mains emergency power supply for critical users, e.g. in power plants, industrial plants, hospitals, high-rise buildings
special applications such as:
frequency converters, UPS-systems, and systems solutions meeting the highest demands in terms of design and/or electrical performance
The generators are suitable to be driven by:
Diesel and gas engines; gas, water and steam turbines; power-take-off (PTO) gearboxes; windmills.
Available outputs range from 150 kVA to 30 MVA, from low voltage up to 15 kV. Frequency conversion, e.g. 50:60 Hz 60:50 Hz.
|
|
Range available from 2000 kVA to 5370 kVA. (Low, Medium & High Voltage)
• Low Voltage to 690 V
• Medium Voltage to 4160 V
• High Voltage to 13,800 V
* Single or 2-bearing construction.
* PMG/AVR control.
* Form wound stators are standard on MV80/HV80.
* Engine Adaptors to SAE00+0, coupling discs to SAE21 & 24.
* IP23 enclosure protection is standard.
* Marine version available.
|
|
|
|