Ferraz Shawmut offers the most extensive line of fuses worldwide. This line is matched by our line of fusegear. Amp-Trap® UL-CSA fuses line is supported by UltraSafeTM holders line and a complete range of power distribution blocks. For IEC low voltage fuses Modulostar® is a complete and innovative line of holders and disconnectors for ferrule-type fuses, Lindner encompasses numerous solutions of bases, holders, switch-disconnectors for DIN standard fuses, holders also for BS88 standard Blue Dot fuses.
Protistor® fuses for power electronics can be mounted in Modulostar® holders and disconnectors when they are of ferrule-type and in IP20 bases when they are of square-body type.
Ferraz Shawmut offers also non-fused and fused switches. |
|
IM switch-disconnectors are part of switch-disconnectors suitable for local load break and low voltage load break of electrical circuits.
They are often used for following applications :
Main switch
Motor switch
Disconnector
Safety switch
They are available up to 6 poles with rating from 40A to 800A.
Devices with visible load break with view of moving contacts in open position.
Right side lateral handle and fast moving contacts.
Compliant to regulations : CEI 947-1 and 3 –BS 5419 NFC 63130
High performance load break/make capacity.
CC 23 and DC 23 classified
High electrical and mechanical endurance
Safety covers to avoid accidental touch.
Wide range of accessories
Range :
Ratings 40A - 63A - 80A – 160A - 200A – 315A – 350A - 500A – 630A – 800A. |
|
The switch disconnector VISYS is particularly suitable for making
and breaking on load low voltage electrical circuits.
They are commonly used for the following purposes:Main switch,Switch for motors
,Disconnector,Safety switch.
Characteristics:
Insulation voltage AC 1000V and 1500V DC,
Top breaking capacity AC-22, AC-23, IEC 947-3
High electrical and mechanical endurance
Double breaks per phase
Real and direct vision of contacts
Handle with an indication of the position of contacts
Visible cut-off, visual access to the mechanism of contact
Sudden trigger mechanism, beyond control of the operator speed manoeuvring.
Suitable protections to prevent accidental touching.
Extinguishing firewall (VO-UL94), with a high mechanical and electrical resistance.
Wide range of accessories.
Insulating external front handle, lockable by 3 padlocks in closed position, equipped with a system of double locking.
Direct handle (padlockable on request).
Composition of the range:
20 different sizes 32A to 3150A
6 different sizes and available in 3, 4, 6 and 8 poles |
|
Craig and Derricott is renowned for delivering quality engineered, easy to install isolation equipment with an extensive range of configurations and enclosures. Ratings from 6 to 1000 A and available in shortlead times, our IP65 solutions are available in two distinct ranges.
The ‘Trent’ range now includes EEx equipment for Zones 21 & 22 & the ‘Classic’ has a new range of Automatic Transfer Switches (ATS) designed to assist in maintaining essential supplies.
The Trent Range is a new family of Isolation Equipment which draws upon our extensive industry knowledge to provide fast, easy to install solutions. Switch, Changeover and Fuse Switch Disconnectors are available for rapid delivery and can be supplied in a variety of enclosures including:
Die-cast Aluminium
Sheet Steel (Red or Grey)
Stainless Steel (Surface or flush mount)
Polycarbonate
Polyester |
|
SIRCO M offers a large number of accessories that are available for all products of the series.
Application
- Distribution Panel – Incoming or feeder
- Panel mounted or DIN modular
- Local safety isolation
- Machine control
Originality and advantages:
- With a limited number of references it is possible to create solutions for various applications.
- The integration of an innovative switching concept patented by Socomec allows for a universal switch within the same product (direct or external operation via a right or lateral side handle).
- All products are modular, of constant depth and allow for quick and easy installation: the switches are DIN rail or screw-mounted. Most accessories are fixed with snap-on fixing brackets.
- Highly innovative design for a multitude of applications.
- Many accessories such as auxiliary contacts with pre-break and signalisation functions, handles for direct or external operation as well as additional fuse-holder modules are already available.
Features:
- From 16 to 160 A, 3 or 4 pole.
- The association of two 3 or 4 pole ‘standard’ switches with a standardised accessory enables the assembly of:
- 6 or 8 pole load break switches.
- 3 or 4 pole changeover switches (I-0-II) or (I-I+II-II). |
|
GE ML Disconnects are a turn for the better because they eliminate all the unnecessary complexion in selection, ordering and application.
The ML disconnects are UL508 manually operated horse power rated IEC disconnect switches available in 5 amperage frames from 25A through 125A. Mounting options include front (flush) mounting, either central or 4 hole, and rear mounting - on a panel or DIN rail, with or without a hinged door. Switches may be ordered as open or enclosed (3 through 6 pole with or without 1 NO/1NC auxillary contacts).
|
|
The range consists of:
SIRCO DC 40A/SIRCO DC 125A/SIRCO DC 250A
Original features and advantages:
The innovation is at entry level, namely SIRCO DC 40A. This product has no equivalent on the market in terms of compactness and performance, i.e.:
- 8 break points in series per pole to split and extinguish the electrical arc.
- Use of thermoplastic materials to resist temperature rises due to the arc.
- Designed according to UL standards to increase insulation distances.
- Rapid connection and disconnection which is exceptional in equipment of this volume.
SIRCO DC 125A and SIRCO DC 250A circuit-breakers complete the SOCOMEC photovoltaic range.
These are also DC22 -800V with contact geometry designed to facilitate extinction of the electrical arc. |
|
Current rating from 32 up to 100A. Panel, base and DIN rail mounted. Available in the 2, 3
and 4-pole version with central control knob and through shaft.
2 and 3-pole fuse holders for switch-disconnectors up to 32A. |
|
| ... products without technical information |
| |
Rated voltage 12, 24, 36 and 38.5 kV
Rated current 630 A and 1250 A
Switch-fuse combinations are used for operational medium voltage-side on and off switching of distribution transformers in secondary substations. They additionally have the task of protecting these transformers against the impact of internal and external faults.
These combinations comprise a functional unit of switch disconnectors and back-up fuses.
By means of the fuses the breaking capacity of the combination is extended beyond that of a simple switch disconnector up to the rated short-circuit breaking current.
The high-voltage high breaking capacity fuse, according to statistics of the VDN (German Association of Electricity Network Operators) is rated as reliable transformer protection. The h.v.h.b.c. fuse in combination with a switch disconnector provides a simple solution which is very economical to procure and run.
This provides a clear-cut advantage over a circuit breaker with the associated current transformers and overcurrent time protection.
Besides this, the h.v.h.b.c. fuse has a current limiting effect when short-circuits occur and reliably interrupts the fault current of the first half cycle.
These properties are advantageous for the dimensional design of the network.
|
|
This Outdoor high performance disconnectors are manufactured for high currents und difficult environmental conditions. That means high pollution degree up to PD4 and high operating cyles.
Tecnical data up to 38.5 kV, 4000 A, 31.5 kA.
Special field of applications are electic power transformation substations, steel- or mine mills.
All switches can be equipt with manual- or motor actuator, automatical earthing device and auxiliary contacts. |
|
DRIESCHER Indoor Switch-disconnector H 27
• 3-pole
• Rated voltage 12 kV and 24 kV
• Ratec current 630 A
For frontpanel mounting or mounting besiede with or without actuating.
All switches are generally equipped with quick make and quick break operating mechanism.
The switches are designed for normal operating conditions according to DIN VDE 0670, Part 1000, class Minus 5° Indoor.
The peak value of the ambient temperature is 40O C; the average value over 24 hours is 35° C at best.
The values of the insulating power are related to sealevel.
Reduction in insulating capacity at hights up to 1000 m are negligible due to the decreasing insulating capacity of the air.
Refer to brochure 727 |
|
DRIESCHER - Indoor Disconnectors, Fuse Bases, Earthing Switches
• Rated voltages Ur
12 kV, 24 kV, 36 kV and 38,5 kV
• Rated currents Ir
630 A, 1600 A, 2500 A, 4000 A and 6300 A
The 1-, 2- and 3-pole Disconnectors ITr are applicable for a rated voltage range of 12 kV, 24 kV, 36 kV, 38,5 kV and a rated current range from 630 A
to 6300 A.
The rated short time current upto 63 kA for a duration of 3 s depending on the model has been tested.
The 3-pole Earthing Switches ES can be used for a rated voltage range of 12 kV, 24 kV, 36 kV and 38,5 kV.
A rated short time current of 20 kA and 31,5 kA is specified.
The described Disconnectors are intended for currentless switching in medium voltage switchgear.
All switchgears are type-tested according to EN 62271-102.
For each switchgear an instruction manual for transportation, mounting and commissioning is inclosed. This instruction manual should be
strictly followed. Refer to brochure 731e |
|
Outdoor Disconnecting Switches
Fuse-Bases
Earthing Switches
Single- and three-pole
Rated voltage 12 kV, 24 kV, 36 kV, 38.5 kV
Rated current 400 A, 630 A, 1600 A, 2500 A and 4000
All switchgears mentioned in this list comply with the specifications of VDE 0670 Part 2.
All switchgears are equipped with expoxy resin insulators (colour brown, RAL 8017).
For decades the simple, robust construction proved a success in climatical different regions.
The base frames - a welded work made of sectional steel - and the operating shafts made of bronze are hot-galvanized.
All contacts with flat terminations according to DIN46206 and double disconnecting blades made of electrolytic copper are silver-plated and form loopless current paths.
The fuse holder contacts are designed to the operation of high-voltage, high-breaking capacity fuse-links according to DIN 43625.
Adequate cross-sections and suitable contact pressures result in an easy and troublefree switching even after many years of operation, even under
extreme conditions.
All disconnecting switches and three-pole fuse bases can be delivered with an earthing switch.
Disconnecting can also be equipped with spark quenching horns for disconnecting low currents.
Refer brochure 751e |
|
Outdoor Switch-disconnector FLa15/60
used for vertical and horizontal mounting on wooden or concrete pole
Rated voltage 12, 24, 36 and 38.5 kV
Rated current 400 and 630 A
For decades DRIESCHER - Outdoor switch-disconnector have been used as line sectionalizers in medium voltage overhead line networks and have
proven to be extremely satisfactory based on their reliability and operating safety.
The switch is in compliance with the regulations as per DIN VDE 0670
Part 301.
The arc extinguishing device in its weatherproof housing, operates in accordance with the oil flow principle of the well-established DRIESCHER circuit-breakers and is shunted in the On condition.
The switch frame and the operating shafts mounted in bronze bearings are hot-galvanized. All insulators used in the construction are made of
cycloaliphatic cast resin (Color RAL 8017 brown).
The contacts with flat terminations in accordance with DIN 46206 are made of electrolyte copper and are silver plated.
Even after many years of operation, a spring guarantees a constant
contact pressure as well as easy and satisfactory switching.
The nuts, washers and spring washers of stainless
steel ensure corrosion-free connections even under extreme climate conditions.
Refer brochure 762e and 763e |
|
DRIESCHER - Outdoor Switch-Disconnector
Type FLa 15/97
• Rated voltage 12 kV, 24 kV, 36 kV and 38.5 kV
• Rated current 400 A and 630 A
• 1-pole and 3-pole design
Contrary to former outdoor load-break switches in which it was common practice for the arc to be extinguished in oil, with the new developed outdoor switch-disconnector FLa 15/97 arc extinction takes place in a vacuum interrupter.
Based on a patented insulating system there is also no liquid or gaseous medium required for the external insulation strength of the vacuum interrupters.
The vacuum quenching device is embedded in a weather-proof insulating housing.
This switchgear is therefore also recommended for special applications (e.g. in water protection areas).
The outdoor switch-disconnector is capable of switching on its rated current as well as its rated short-circuit making current via the main contact system.
The disconnecting process is implemented via the shunt-connected vacuum interrupters, resulting in no external arcing phenomena.
A fully developed eccentric make-and-break mechanism operates the vacuum interrupters and ensures Class M2 with regard to the mechanical strength (corresponds to 5000 mechanical operating cycles).Fefer brochure 766e
|
|
| Disconnecting switches for indoor mounting 12kv and 24kv with porcelain insulators, with and without earthed knifes , RM, RMZ, RMZk |
|