The RF identification system for production control.
- DTS125: Industrially compatible identification system in 125 kHz technology.
- Coding of workpiece carriers in routing conveyors.
- Quick and easy set-up: Plug and play.
- Read/write head requiring little space due to narrow design.
- Compact and at a low cost: Antenna and evaluation in one housing.
Innovation in production control
The constant increase of the degree of automation in modern production plants is increasingly supported by identification systems. Their tasks include for example the control or release of production steps or the assignment of information about each product.
|
|
Balluff provides a range of RFID systems to track work in progress and provide feedback on in-process testing. Computer-assisted manufacturing, modern warehouse systems, flexible assembly lines, plus logistics and distribution systems benefit from Balluff BIS RFID systems.
Balluff has developed a complete line of easy to use read-only systems that interface directly into a PLC through discrete inputs or an RS-232 interface. These systems offer data reliability and environmental ruggedness not found in bar code systems. Read-only systems are ideal when product data are stored centrally in a control system and referenced by a code contained on RFID tags located on products, parts, or pallets.
|
|
Kemro UserID - the intelligent identification method
This innovative module for a quick and simple user identification makes an enormous increase in machine and plant productivity possible.
The Kemro UserID product line offers an optimal and comprehensive solution in this regard. With this solution, both the cumbersome user registration with names and passwords, as well as the extensive efforts needed for the maintenance and administration of user data, are no longer necessary at the machine level.
Kemro UserID not only registers names and access rights; with it one can also define a large variety of settings for each operator, such as the preferred language of the visualisation screens. This means that every user will immediately have the accustomed visualisation environment and preferred language at his disposal.
|
|
|
|
|
|
Active RFID System FC-406:
Applications
. Mine worker tracking security system
. Hospital Intelligent management
. School security system
. Intelligent residential area management
. Prison security management
. Asset tracking and management
. Entry management
Features:
Low power consumption design,battery life 1-3years
Able to replace battery
IP67 water-proof level
Two call buttons
Anti-collision design
Two-color LED display
Speaker inside Tags
Range between tag and reader over 100 meters
RFID system is composed of three parts:
Tag: Each tag has a single ID code.
Reader: The device for reading or writing the tag information. It has two
kinds of reader: Fixed reader and handheld reader.
Antenna: To transfer the signal between the reader and the tag.
The reader provide the standard RS-232 interface and USB interface, The interface rate is 19200bps(8N1).
Specification:
Tags
Frequency :433.92MHz,868MHz,915MHz
RF data rate :19.2kbit/s
Modulation:FSK
Dimension: 65mm*42mm*14mm
Housing: ABS
Memory:read/wirte, 1k bytes
Storage Temperature: -30C--+70C
Reader
Frequency :433.92MHz,868MHz,915MHz
RF data rate :19.2kbit/s
Modulation:FSK
Dimension: 85mm*55mm*25mm
Housing: ABS
Storage Temperature: -30C--+70C
|
|
The TURCK identification system is a so-called RFID system (Radio Frequency IDentification).
Data are exchanged by electromagnetic waves.
The system operates wear-free and non-contact and is insensitive to temperature fluctuations (high temperature data carriers), dirt as well as water and oils.
Furthermore, it has a very long service life.
The system is comprised of:
- a mobile data carrier
- a read/write head
- a processor unit (interface module)
|
|
|
|
|
|
The RFID system ID 200 has a modular, flexible construction and is easy to install. It consists of data tags, antennas, and communication modules for reliable identification of components. The mobile, compact data tags, readable from several sides, offer up to 2 KB of memory in FRAM technology, which enables an almost unlimited number of read and write cycles. The round and planar antennas use internationally standardized frequencies of 125 kHz and 13.56 MHz, respectively. The antennas are integrated into the superior control system via the communication modules with Ethernet or PROFIBUS DP interfaces. Two antenna connections ensure efficient communication and data transmission that is resistant to interference.
Both antennas can be active simultaneously and can be used with different frequencies. If an error should occur nonetheless, the integrated web server facilitates diagnosis.
ID 200 offers you the following benefits:
* Large variety of interfaces in addition to PROFIBUS and Profinet, system also supports EtherNet/IP, TCP/IP and Modbus/TCP
* Standardized frequencies and transmission protocols - common data tags can be used
* Integrated web server for simple diagnosis
* Simultaneous use of 2 antennas also with different frequencies (125 kHz/13.56 MHz)
* Reliable reading, also while passing by
* Plug & run solution for all transfer systems and VarioFlow
|
|
Control Boards
The Control Board is the central processing unit that handles information being passed from a host device (PLC, Computer, I/O Device) onto a Balogh RFID Tag. All Balogh Control interfaces have been designed for the specific bus architecture it functions on. This means no gateway devices, no passthroughs, and no special software.
|
|
For decades SICK has offered a large number of solutions in the field of identification for almost any problem. Now the product portfolio has been expanded by a new technology: Radio Frequency Identification.
Logistics, curier express parcel services, automobile manufacture - RFID can be utilized to identify pallets, ensure smooth transport of totes or match the content to the right transport box.
RFID allows identification, even with difficult environmental conditions, without visual contact between reader and object to be identified. This allows a reliable and fast detection. Identifying faster means commissioning faster - commissioning faster means higher efficiency and therefore real cost reduction.
SICK as a complete supplier for Auto Ident applications opens up a great variety of application possibilities with RFID and barcode.
|
|
|
Omron's Radio Frequency Identification (RFID) systems act as portable databases allowing information to be accessed and modified at any point on the production line providing a non-contact, non-line of sight method of automatically gathering, inspecting and distributing production data.
|
|
|
Datalogic can offer the market one of the most complete ranges of radio frequency identification devices, and includes read-only and read-and-write systems, both active and passive. These identification solutions are suitable for anything from harsh industrial applications to clean rooms, and include RFID offerings ranging from 125 KHz to 13.56 MHz and Network Interface Modules.
|
|
Our resourcefulnesses `identification ID allow a sure and fast identification of parts. The head D `writing/reading (SLK) offers a connection by various interfaces: multi-poles, bus -I, drank Profibus-DP,...
The mobile supports of data (MDT) have a nonvolatile EEPROM (a safeguard by pile N `is not necessary) with a capacity going until 8k bits of memory. Moreover, the data carriers can not only be gone up on the top of the pallet part holders, but also in lower part see being integrated completely in the pallets part holders.
The ID allow a dynamic transmission of the data until a speed of transport reaching 20 m/min.
|
|
| ... products without technical information |
| |
Latch Lock dual key entry
This lock allows the locking of accesses such as sliding doors, caps, casings and other guards.
Made up of stainless steel to resist to aggressive or corrosive environments.
The NXOOL lock equipped with the optional Chain Key can support a high degree of misalignment.
|
|
| ... products without technical information |
| |