We offer a variety of displays from simple single-channel devices
to networked multi-channel MODULAR 600 systems.
|
|
Measurement Specialties instrumentation for AC-operated LVDTs and gageheads eliminates compatibility problems for signal conditioning with your Measurement Specialties LVDTs.
Instrumentation performs:
Excitation
Amplification
Demodulation
Signal modification
Readout/control
|
|
The EURO-SYSTEM consists of a set of 100 x 160 euro-card.
A set operates transducers with transducer supply, amplification and high level signal processing : +/-10V and 4-20mA.
9130
Inductive transducer conditioning unit
|
|
Displacement, Position ...
For all LVDT and RVDT transducers
Input ½ bridge or full bridge.
Transducer power supply included
Accuracy and stability.
Fast replying time.
Analogic output ±10 V or 4-20 mA.
Zero and gain adjustment
Electronic calibration simulator
Easy adjustment
|
|
SERIES 1000 Oscillator/Demodulator
The Series 1000 Oscillator/Demodulators are designed and built to provide DC-in/DC-out operation for AC LVDTs. For additional stability of the output signal, these units are internally regulated. Two versions are available for AC transducers that are optimized for either 3 or 7 kHz performance. VDC or 4-20 mA output versions also available.
SERIES P010 PC Board Oscillator/Demodulator
The Series P010 OEM PC Board Oscillator/Demodulators are designed and built to provide economical DC-in/DC-out operation for AC LVDTs. For additional stability of the output signal, these units are internally regulated. Two versions are available for AC transducers that are optimized for either 3 or 7 kHz performance. The small size of this board makes it ideal for applications where space is limited. End-users will also enjoy a significant cost savings over our Series 1000 O/Ds.
|
|
|
These precise and reliable signal conditioners deliver peak performance from our Miniature Tilt Sensors. They are available in rugged housings for shop and laboratory work, or as standalone circuit boards for your OEM applications. Single-, dual- and multiple-channel units are available, as are a range of output options, including analog voltage, 4-20 mA and serial data output. Units with analog output are sold with fixed or switchable gain and filter settings. From our low-cost Basic Signal Conditioner to our benchtop Model 781 and rack-mount Model 786, you’ll get the most out of your tilt sensors when you use these versatile products.
|
|
|
|
|
|
Key features
- Available as Starter kit
- Strain gauge, Pt-100 and potentiometric sensors
- CAN Interface
- 18 Bit A/D converter resolution
- Up to 5 Km cable
- Selectable bus-speed
- Daisy chain upto 60 devices
There is an increasing tendency to investigate the behaviour of large constructions under varying load conditions. Examples are: bridges, wind turbines, tower cranes, etc. Usually it is quite inconvenient to apply half- or full straingauge bridges onto such constructions, for which reason mostly single (1/4 bridge) gauges are utilized. This, however, usually implies cumbersome wiring to the inputs of the (remote) measuring amplifiers.
StrainBUSter has been developed to solve these problems by placing the measuring circuit in the direct vicinity of each point of measurement. Here all signal conditioning is done, after which all measured values are being transmitted via a CAN bus to one convenient central place, thus building one decentralized system. In this way, up to 120 measured values can be transmitted very reliably over longer distances.
Each StrainBUSter module has 2 separate input channels. The single straingauge, or the Pt100 sensor, is connected through a 3-wire connection, eliminating cable losses at the input side.
|
|
The Fredericks Company has a variety of electronics products based on our industry leading tilt sensors. These high-accuracy, microprocessor based electronics can range from printed circuit assemblies to fully integrated packages, as well as remotely mounted sensors and assemblies.
Our dual axis electronics are highly configurable and provide the user with an output signal proportional to tilt. These electronics can be used with any of our TrueTiltTM, glass, or ceramic tilt sensors.
For users requiring special features, The Fredericks Company can design and manufacture electronics tailored to your application. The electronics can be packaged in a variety of ways to provide the user with easy mounting, multiple output options and environmental protection.
|
|
The Electro-Sensors SA420 Signal Conditioner is a complete system which provides an analog signal directly proportional to the speed of a monitored shaft. The 0-10 Vdc and 4-20 mA outputs can be sent to a chart recorder, digital display, PLC, loop controller, drive speed controller, or any other control or monitoring device. The wide voltage range and wave shape flexibility of the SA420 input circuitry allow it to translate signals from Hall Effect Sensors, proximity switches, magnetic sensors, and a wide variety of other pulse generators, into analog outputs.
Features:
- DIN Rail Mount Enclosure
- 0-10 Vdc and 4-20 mA Outputs
- Accurate at Slow Speeds
- Interfaces with a Variety of Sensors
- Input Frequencies to 10 kHz
- 115 Vac Standard, 220 Vac, 12/24 Vdc Optional
- LCD Display For Field Adjustable Calibration
- Additional DIN Rail Available - Consult Factory
|
|
The 6mm-wide WAGO isolation amplifiers and transducers share a common profile and can be easily commoned rather than requiring complex discrete wiring. The plug-in relays can easily be changed from above the unit.
The 857 Series includes preset and configurable isolation amplifiers, passive isolators, repeater power supplies (also for HART applications), signal splitters and temperature transducers for both PT 100 sensors and thermocouples.
Meeting some of the highest quality requirements: The extended temperature range of –25°C to +70°C permits a wide range of application areas. All devices provide safe isolation of input, output and supply circuits with 2.5kV test voltage to EN 61140. Signal transmission accuracy for measured data is less than 0.1%.
|
|
| ... products without technical information |
| |
mPDS 2000V3 Evaluation Unit for Process Transducers
Anton Paar's mPDS 2000V3 evaluation unit is ideal for complex measurement tasks with process transducers. mPDS 2000V3 provides a clear graphical overview and user interface. All established process interfaces are available (digital/analog inputs/outputs, Profibus, RS 232, RS 485). Numerous user programs are integrated and you can add your own concentration calculations. According to your application, the flexible software allows you to add, for example, a Carbo CO2 analyzer for beverage analysis or other units for additional concentration measurements.
Limit monitoring
* Alarms help you prevent out-of-spec production
* Up to 255 products can be selected
Flexible connection to your plant
* Perfect integration via analog, digital and bus interfaces
Automatic and continuous data recording
* Optional PC software for modern data analysis
* Profibus option
|
|
|
|
|
|
Gas density controllers
These operate mechanically. The density of the sample gas is compared via a bellows system with the gas density in a reference gas chamber. If the density of the sample gas alters, the bellows system actuates one or more micro switches. Gas density controllers function independent of any power supply.
Trafag gas density controllers are employed internationally in gas-insulated, high-voltage switchgear in power distribution networks. Their performance record is worldwide is unique. Even at climate-related temperature fluctuations of over 135°C, they provide precise measurement results and function reliably and maintenance-free. They are therefore to be found all around the world, in the ice-cold polar regions or under the blazing desert sun.
Gas density sensors
function electronically. The consistent resonant frequency of a quartz oscillator under vacuum is compared with the resonant frequency of an identical quartz situated in the sample gas. The difference in the resonant frequency is proportional to the density of the sample gas. This difference is processed into a digital or analogue output signal.
|
|
Features
* High Flow Capacity of 100 SCFM (170 m3/HR).
* Output pressure displays in psig, BAR, kPa, or user-defined pressure units.
* Reverse acting capability for analog input and output signals.
* Select Current or Voltage mode for input signal.
* Independently adjustable PID?tuning coefficients.
* Fully functional keypad and display.
* Backlit Liquid Crystal display screen.
|
|
MICRO TC
It%u2019s a rotary contactless transducer for transmission of signal temperature from a rotating element to a stationary part.
The output signal may be 0-20ma, 4-20ma. ( 0-5VCC)
Max RPM. 5000.
Important in this transducer is the security between the input signal
(thermoelement) and output analogic signal. The transmission from rotating part and stationary is optical. A receiver circuit reconverts the digital signals in analogic output.
The galvanic insulation avoids eventual damages at equipments connected in stationary side, in cases of short circuit from thermoelement and electric resistors.
The following versions are available:
micro tcj for thermocouple j type
micro tck for thermocouple k type
micro tctr for thermocouple pt100
|
|
|
|