- Electricity - Electronics >
- Switch and Relay >
- Single-pole circuit breaker
Single-pole circuit breakers
Primary current: 1 A - 50 A
... as on/off switches. Double pole breakers are mostly used for 230 V systems, which interrupt the current both in the phase and neutral wires. Mastervolt supplies a wide variety of single ...
Primary current: 1 A - 63 A
VAC: 240, 415 V
... overload and short circuit protection, applies to a circuit of AC 50Hz,rated voltage 230/400V, rated current up to 63A. Usually it functions as un frequently switching. In addition, it can be also used ...
ZHEJIANG VEKON TECHNOLOGY CO.,LTD
Primary current: 0.05 A - 10 A
VAC: 240 V
VDC: 48 V
Miniaturised single pole thermal circuit breaker with push-to-reset tease free, trip-free, snap action mechanism (R-type TO CBE to EN 60934) integral type. Approved to ...
E-T-A
Primary current: 4,000, 3,150 A
VAC: 363, 252 kV
Circuit breaker is used for making and breaking normal current, fault current and switching lines to realize the control and protection of power system. Each pole of LW10B-252 circuit ...
Primary current: 6 A
VAC: 230 V
Description Miniature circuit breakers series ETIMAT 6 are high quality devices, produced in EU, with following technical characteristics: Rated short-circuit capacity: 6.000 A Number ...
ETI
Primary current: 160 A - 250 A
VAC: 240 V - 690 V
VDC: 125, 250 V
160A and 250A frames of new compact breakers can provide saving space and saving money to you.
Primary current: 6 A - 63 A
VAC: 240, 415 V
... protection against overload and short circuit for all domestic,commercial and any low voltage distribution systems. · Only 18mm for 1P, 36mm for 2P, 54mm for 3P and 72mm for 4P · Overloaded and short circuit ...
WENZHOU RENA ELECTRIC CO.,LTD
Primary current: 10 A - 250 A
VAC: 240 V - 690 V
VDC: 125, 250 V
Circuit breakers protect human lives, buildings and properties against risks of electrical short circuit. Since our founding, TERASAKI has left competitors far behind in the field of ...
Primary current: 0.1 A - 50 A
VAC: 415, 250, 240, 80, 32 V
VDC: 80, 65 V
... method 213 Vibrations: IEC 68-2-6 Mil-std 68-2-3 Umidity: IEC 68-2-6 Mil-std 68-2-3 Note Single or multipole small size circuit breaker, handle, rocker or sealed mount ...
COMESTERO SISTEMI
Primary current: 1 A - 63 A
VAC: 250, 500, 750, 1,000 V
VDC: 0 V - 1,200 V
Anson NKC1-63DC Series PV DC Isolator Switches are mainly be used in PV solar power system, which are applied for DC solar combiner box, controller etc. The Max voltage up to 1200VDC, current up to 63A, with the function of effective ...
SHANGHAI ANSON ELECTRIC TECHNOLOGY CO.,LTD
VAC: 230, 400 V
Rating: 6 A - 63 A
... type is mainly used in AC50/60Hz single pole 230V or two, three, four pole 400V voltage for overload and short-circuit protection as well as for un-frequent on-and-off ...
Primary current: 6 A - 63 A
VAC: 230, 400 V
... AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent ...
Primary current: 6,000 A
VAC: 230 V
Rating: 25 A
- Tripping curve: B, C B - The maximum current release breaks between 3 and 5 In; used to protect long circuits and generators С - The maximum current release breaks between 5 and 10 In; used to protect main power supply ...
Elmark
VAC: 230 V - 400 V
Switch-selector-circuit breaker magnetothermal under airtight case IP 55 with position contacts (10 + 1F). Standard equipped with a coil with tension emission enabling the setting off at a distance ...
Primary current: 1 A - 63 A
VAC: 400, 230 V
... 63 Series miniature circuit breaker is mainly used in AC 50Hz/60Hz, rated voltage of 230V/400V, and rated current up to 63A for overload and short circuit functions, and also for not-frequent ...
Radin Electric Technology Co., lTD
Primary current: 2 A - 63 A
VAC: 230, 240, 415, 400 V
VDC: 48 V
... series miniature circuit breakers provide the customer a comprehensive efficient, reliable protection of equipments, cables and installations in buildings for over load and short circuit ...
Primary current: 16 A - 225 A
VAC: 380, 415 V
Primary current: 125 A - 225 A
VAC: 690 V
... Standards:CNS14816-2 (IEC60947-2) Voltage Ui:690V Current:125.150.175.200.225A Pole: 2P 3P Breaking Capacity: Icu: 220V/ 85kA (sym) 380V/ 50kA (sym) 440V/ 42kA (sym) Ics = 50% Icu Accessories: AL.AUX. ...
Shihlin Electric & Engineering Corporation
Primary current: 0.5 A - 100 A
Single Pole AC fitted with Plug-in Terminals Curves: • AS (Long Delay) • BS (Medium Delay) • CS (Short Delay) Mounting Options: Metric or Imperial Mounting Approvals: • IEC60947-2 • UL489 • ...
CBI-electric: low voltage
Primary current: 1 A - 63 A
VAC: 110 V - 480 V
Function Protection of circuits against short-circuit currents, Protection of circuits against overload currents, Switch, Isolation, Circuit-breakers ...
Primary current: 2 A - 63 A
VAC: 230 V - 415 V
DZ47-63 MCB is suitable for the distribution circuit of AC 50/60Hz, rated voltage up to 400V, rated current up to 63A, rated short-circuit breaking capacity does not exceed 6000A, as the use of circuit's ...
Primary current: 5 A - 60 A
... for use in 1RU circuit breaker panels, these single-pole standard delay circuit breakers provide reliable circuit ...
Primary current: 5, 25, 15, 30 A
VDC: 65 V
ICT snap in circuit breakers are designed to provide reliable, long lasting service where high voltage and current handling are required. Features & Benefits 5-, 10-, 15-, 25- and 30-Amp versions ...
Your suggestions for improvement:
Receive updates on this section every two weeks.