The JMS-Q1000GC UltraQuad™ GC/MS is a highly sensitive, quadrupole Mass Spectrometer. Its high sensitivity, S/N>=120 (rms) for m/z 272 of 1 pg octafluoronaphthalene (scan mode) and S/N>=120 (rms) for m/z 272 of 0.1 pg octafluoronaphthalene (SIM mode), is unsurpassed and is actually 1.5 to 2 times that of conventional mass spectrometers. The resolution of this instrument is more than 3M (>=2000 at m/z 614 of PFTBA) which is obtained using the high-precision hyperbolic Quadrupole.
By adopting a high performance split flow turbomolecular pump, the JMS-Q1000GC UltraQuad™ develops extremely stable operation over an extended period of time.
The JMS-Q1000GC UltraQuad™ also has a removable ion source block which is easy to maintain and clean.
|
|
|
The IMS1280 is based on a double focusing mass spectrometer with a large radius magnetic sector (585 mm). The secondary ion optics has been optimized to work at full transmission up to 6000 mass resolution. This very high transmission coupled with ion bombardment of oxygen or cesium allows the measurement of isotope ratios for species at trace level concentrations (U/Pb dating experiments) or for stable isotopes (oxygen or carbon). The automation level and new control of the optics parameters lead to an exceptional reproducibility on isotopic ratio measurements that is not achievable on any other SIMS instruments (0.1permil level external reproducibility).
|
|
The CAMECA SIMS 4600 is a full-wafer quadrupole SIMS with top performances in next generation semiconductor element depth profiling. Based on the experience gained with the SIMS 4550, it provides the same performances but add the 200mm or 300mm full wafer analyis and mapping capabilities (see example below). The wafers are handled horizontally and the geometry has been optimized in order to be compatible with:
- single normal incidence oxygen FLIG gun or
- dual beam configuration (normal oxygen FLIG and 60° cesium FLIG ion guns).
|
|
Network Error
Network Error
A communication error occurred: ""
The Web Server may be down, too busy, or experiencing other problems preventing it from responding to requests. You may wish to try again at a later time.
|
|
|
|
|
|
Mass Spectrometry (MS) is one of the fastest-growing areas in analytical instrumentation. Magnetic sector and time-of-flight mass spectrometers (manufactured by JEOL) have very high stability, sensitivity, and resolution. These instruments are used in both quantitative and qualitative analysis, including high-resolution accurate mass measurements for the determination of elemental compositions. The use of mass spectrometry in support of synthetic, organic, and pharmaceutical chemistry is well established. However, mass spectrometry is also used in materials science, environmental research, and forensic chemistry. It has also evolved into one of the core methods used in biotechnology.
JEOL manufactures a wide range of magnetic sector mass spectrometers ranging from small bench top double-focusing magnetic sector mass spectrometers to larger tandem and hybrid mass spectrometers. JEOL also offers the new cost-effective high-performance AccuTOF™ API-TOF LC/MS system for qualitative and quantitative analysis.
|
|
MALDI SYNAPT HDMS
A dual ionization mass spectrometer featuring MALDI and atmospheric pressure ionization. The system is operable in both time-of-flight (TOF) and ion-mobility/TOF modes.
Features:
- Triwave™ Technology, which provides access to the unique benefits of Ion Mobility Spectrometry (IMS)
- Time-aligned parallel (TAP) fragmentation for first- and second-generation fragmentation structural information in a single experiment
- Rapid, exchangeable MALDI/API sources
- High-duty cycle (HDC) mode for enhanced sensitivity over a wide mass range
- Integrates with the nanoACQUITY UPLC® System and the CTC PAL MALDI Spotter/Fraction Collector, so you can perform off-line nanoscale separations with minimized sample complexity and dynamic range issues
|
|
|
|
|
|
Since 1976 Extrel has been building high performance Process Mass Spectrometers for a wide range of industries. The analysis speed and wide dynamic range our process mass spectrometers have made them the analyzer of choice for processes which have fast kinetics, dynamic composition changes, or have many sample points that need to be analyzed in a relatively short time period. The reliability, ease of use and innovative designs of our industrial analyzers have allowed Extrel become the process mass spectrometer market leader in many industries.
Today Extrel builds a wide range of Process Quadrupole Mass Spectrometers. Our MAX300 series are high performance gas analysis systems that can be used for everything from process development to pilot plant monitoring to full production control. These systems are the seventh generation of Process Mass Spectrometers for Extrel and they run the fifth generation of our powerful process software.
We back our system with 30 years of experience in process analysis and in-depth application knowledge. Our experience in installation, training and technical support will get you up and running quickly and easily and keep you up and running to keep your process at its best.
|
|
The MAX LT Systems are high performance Quadrupole Mass Spectrometers mounted on 62 CF ( 41/2 inch) flanges. They are designed for the researcher who needs a real mass spectrometer but is on a limited budget.
The MAX LT system uses Extrel's high transmission 9.5 mm rod tri-filter quadrupole mass filter and the same powerful, flexible and easy to use Merlin Automation Software that our MAX systems do.
The MAX LT system are complete with EI Ionizer, Mass Filter, Detector, Power Supplies, Controller and Software.
The MAX LT systems are ideal for TPD studies, SIMS, plasma analysis, flow tube detection, catalysis studies and much more.
|
|
|
|
|
|
Ion Chemistry
Quadrupole Mass Spectrometers and MS and MS/MS Components for Ion Chemistry Studies. Extrel has been building high resolution, high sensitivity instruments for ion chemistry studies in both research and industry since 1964.
- Drift Cell and Flow Tube Detection
- Plasma Monitoring
- Atmospheric Chemistry Studies
- Multi-quadrupole and MS/MS Systems
Extrel CMS builds a range of standard and custom systems and components for research and industrial ion chemistry applications. These include:
Add-on QMS Full Quadrupole Mass Spectrometers that you bolt on to existing systems to add high sensitivity, high resolution analytical capability.
Use one of our MAX 500 systems as the detection for Flow Tube and see everything from mass 1 to 500.
Components A full range of high performance Quadrupole Mass Spectrometry Components that you can use to build your own Ion Chemistry system or to improve the performance of an existing system. Extend the mass range of your current system or improve its sensitivity by an order of magnitude or more by adding our high transmission quadrupoles mass filters and a rock solid RF supplies to it. Add one of our 19 mm quadrupole mass filters and one of our 1.2 MHz RF power supplies as an injector quadrupole for your SIFT system
Special Systems Understand and improve your PECVD or Etch process by adding our plasma analysis ms modules to your system.
|
|
|
|
|
|
Results. Better. Faster. Take your GC/MS to the limit with the Clarus® 600 Gas Chromatograph/Mass Spectrometer (GC/MS). It delivers the performance and throughput you require with the ruggedness you demand.
The compact Clarus 600 GC/MS, with its advanced electronics, features the widest mass range and best-in-class detection limits of any quadrupole MS. Our high-speed scanning delivers far better peak integrity and accuracy. Its gas chromatograph has the fastest heat-up and cool-down oven in a conventional GC. Multiple pumping options offer an instrument for every lab’s needs.
- State-of-the-art electronics provide fast scanning and increased
productivity
- Plug-and-play ion source - click here for demo
- Multiple pumping options offer an instrument for every lab’s needs
- NEW Marathon™ Filament delivers long life even under the most difficult
chromatography conditions
- TurboMass GC/MS software delivers easy environmental compliance
- Fastest heat-up and cool-down oven in conventional GC
PerkinElmer—the clear choice in gas chromatography.
Get results—better and faster with the new Clarus 600 GC/MS.
|
|
LC/MS
LC/MS single quadrupole mass analyser product family including mass directed fraction collection using prep LC/MS and web enabled software.
- LCMS 2010A Advanved
- Mass directed purification
- PsiPort™ mass directed auto-purification software
|
|
|
|
|
|
The DSQ II with the FOCUS GC is a space-saving quadrupole GC/MS designed for laboratories wanting the ultimate in GC/MS performance but having limited space and funds. The system combines the advanced, next-generation curved optics of the industry-leading DSQ II with the small footprint of the FOCUS GCto create a compact but powerful analyzer for environmental, petrochemical, forensics, toxicology and QA/QC applications.
The FOCUS DSQ II is equipped with the next-generation DuraBrite™ XL source and innovative DynaMax XR detection system. This source and detector combination allows detection of smaller concentrations of compounds in difficult matrices, which translates into less prep time, smaller injection volumes, less sample usage, more confidence - real productivity. No more background noise from excited neutrals, no more sample contamination of the sensitive quadrupoles; the curved pre-filter efficiently removes it.
The FOCUS DSQ II is small in size, but big on results. Enhance your productivty with the vacuum interlockfor "no-vent" source maintenance or add an autosampler for unattended sample analysis.
|
|
240-MS GC Ion Trap
Leading the way in GC/MS Analysis
The Varian 240-MS Ion Trap, together with the Varian 450-GC, delivers unparalleled capabilities for both research and routine applications with reliability you expect from an industry leader.
The Varian 240-MS Provides:
- Unsurpassed sensitivity (200 femtogram OFN)
- Less maintenance and high reliability to deliver maximum productivity
- Accurate identification and quantification of trace analytes
- A unique choice of configurations with internal and/or external ionization
- Intuitive software that makes operation simple
- Powerful MS/MS and CI options
|
|
225-MS GC Ion Trap
The True Benchtop GC/MS System
The Varian 225-MS is the world's first mass spectrometer to enclose all of its components, including the foreline pump, in one compact design. For laboratories where space limitations restrict analytical capacity, the Varian 225-MS GC Ion Trap delivers excellent sensitivity and selectivity in an extremely compact unit.
The self-contained vacuum module yields a number of significant benefits:
Because the turbomolecular pump is closer to the foreline pump, it can work at lower speeds and operating temperatures. THis reduces the background which allows improved sensitivity.
For convenience, the module does not require oil changes during its lifetime.
The much quieter vacuum module reduces noise in the laboratory.
Elimination of the hose from the foreline pump to the turbomolecular pump reduces the space requirement significantly.
|
|
|
The new Thermo Scientific LTQ Orbitrap Discovery provides access to the breakthrough Orbitrap™ technology for a wide range of labs. The robust, powerful and cost-effective system is ideally suited for general proteomics and metabolism applications, offering a superior alternative to Q-TOF systems. Featuring high resolution and excellent accurate mass capabilities, this hybrid LC-MS system achieves high throughput label-free profiling for differential expression while the MSn capability makes the instrument ideal for small molecule characterization and structural elucidation. The LTQ Orbitrap Discovery is a highly sensitive system with up to 30K resolution power and an exceptional scan rate, enabling the separation of trace level, isobaric analytes.
|
|
LC Mass Spectrometer: Ion Trap and Quadrupole
500-MS LC Ion Trap
By delivering excellent sensitivity over the entire mass range in full scan mode, and exceptional MS/MS and MSn capabilities, the Varian 500-MS quickly provides superior information for even the most complex sample matrices.
320-MS Triple Quadrupole
The Varian 320-MS provides femtogram sensitivity, a 2000 m/z mass range and a choice of chromatographic and ionization configurations to match your budget and your needs – all in less than 72 cm (28 inches) of linear bench space
|
|
Performance, productivity and confidence.
Welcome to the next generation of the industry-proven Agilent 5975 Series MSD -— the most popular GC/MS of all time. The Agilent 5975C inert MSD with its new Triple-Axis Detector gives you innovative design features that boost your lab’s productivity and advanced analytical capabilities that enhance your results—and your confidence. In addition to delivering better MS resolution and the lowest mass deviation available, the system offers superior sensitivity and spectral integrity. Advanced analysis routines let you get more information from every run, and the latest version of automated spectral deconvolution, identification, and quantification software provides higher quality analyses with even less operator time and attention.
|
|
Unprecedented sensitivity and value
Whether you are quantifying pharmaceutical candidates, measuring trace-level environmental or food contaminants, or confirming biomarkers, the Agilent 6400 Series Triple Quadrupole LC/MS systems offer greater sensitivity, productivity, and value than ever before. The new 6460 with Agilent Jet Stream thermal gradient focusing technology provides maximum sensitivity – breaking the femtogram barrier for many compounds. Or choose the incredible value of the 6410 with femtogram-level limits of detection, Agilent reliability, and lab-friendly ease of use.
|
|
|
|
|
|
UltiMate UHPLC systems with MSQ Plus single quadrupole mass spectrometric detection are easy to use. The UltiMate System's Wellness technology, automatic calibration of the MS detector, and self-cleaning ion source allow for continuous routine operation without the need for frequent cleaning or maintenance. The complete system requires very little setup or fine-tuning to achieve optimum sensitivity. You no longer have to learn two software packages to operate your LC/MS system. Chromeleon® LC/MS software provides single-software method setup and instrument control, powerful UV and MS data analysis, and fully integrated reporting.
With Dionex Intelligent LC (LCi) solutions you can get more out of your LC/MS investment. Technologies such as tandem chromatography allow you to increase sample throughput up to 100%. Other advanced chromatography techniques like 2-D LC or on-line SPE-LC are also available for the UltiMate 3000 LC/MS system, allowing you to automate analyses in your laboratory like never before.
|
|
|
The EM 640S is a mobile GC/MS system with laboratory analytical specifications designed for the fast and accurate, high sensitivity analysis of organic compounds in the environment.
|
|