Controller-starter up to 15 kW
Description
With a capacity of up to 32A/15 kW, TeSys U consists of :
One 45 mm power base (1): 2 ratings, reversing or non-reversing, circuit-breaker function and built-in interference suppression
One clip-on control unit, from a choice of 3: Standard CU : protection against overloads and short-circuits/Expandable CU: + alarm and fault differentiation/ Multifunction CU (2) : realtime control of motor load, local or remote diagnostics and parameter setting
One clip-on automation control module, from a choice of 3 :(3): Modbus, CANopen, AS-Interface et Profibus DP, Ethernet, DeviceNet, Fipio, Interbus S via Advantys STB le module or a simple parallel link
Two optional 45 mm power functions: limiter-isolator(4) and changeover relay (5)
|
|
MDS Digital Soft Starter
With new Iskra MDS soft starter, specifically designed to fit into the same footprint of a conventional
Star/Delta starter, user has the ability to easily replace traditional motor star/delta starter with Digital Soft Starter.
Features:
Adjustable start time 0.5s to 12s
Adjustable stop time 0s to 12s
Run relay
Fault relay
Adjustable motor rating
Integral by pass
Elimination of inrush currents
Smooth stepless acceleration
Improved reliability.
|
|
The Lenze LCU starter drive controllers are the safe and versatile solution for roller conveyors, rotary tables, push skid conveying systems as well as in conveyor technology. The LCU starter can be used as a reversing starter as well as for dual-motor operation. Integrated safety technology provides safe shut off (according to EN 954-1 and IEC 61508). You benefit by saving additional modules and therefore costs.
|
|
|
|
|
|
Electrical Motor Starters
AER Borne Environmental Electrical Motor Starters are designed to provide economical and effective, electrical motor protection. The standard, basic motor starter consists of an industrial grade, UL & CSA approved magnetic motor starter designed for harsh, industrial environments and is built to provide optimum motor protection and reliable, long service life. The heavy duty motor starter is provided with adjustable overload relay/heaters and 120 volt coil. Starter package includes a 120 volt control circuit transformer with fused primary and secondary, momentary push to start button, stop button, external reset button and pilot light housed in a NEMA 12 enclosure. Standard motor starter packages are available for 230 and 460 volt, 60 hertz applications.
Options:
- Installed and factory wired to collection system
- Manual motor starters
- Other input power configurations
- Alternate control circuit voltages
- Alternate enclosures (such as NEMA 4 or 4X)
- Numerous other options and configurations available
|
|
Application examples
- The internal current limitation restricts the inrush current peaks when starting up motors of circular saws, band saws, agitators, mixers, grinders and crushers
- Longer service life and less wear on fan and pump drives
- Controlled start and stop of mechanical handling drives prevent damage to goods and premature wear on plant that is often spread over a large area
- For use as three-phase voltage regulator of heating and lighting installations, as well as for inrush current limitation on transformers
Mains connection
230 - 460 V ±10 %, 50/60 Hz
Control voltage
14 - 230 VAC / DC
Rating range
16 - 900 A
7.5 - 500 kW (in line connection)
11 - 900 kW (in delta connection)
Product characteristics
- Application selector switch with 10 standard applications
- Programmable relay and analog outputs
- Internal motor-protective function (I2t monitoring)
- Motor protection (thermistor input)
- Functional expansion through communication modules.
|
|
C-2000™ Starter
GE's C-2000 IEC Line Starters offers a wide array of contactors, overload relays, enclosures, control transformers and pilot devices to match your application. C-2000 components are loaded with features that make them easier to install, allow more flexible configurations, lower inventory requirements, and make better use of panel space. These components conform to international standards (UL, CSA, IEC-947, and CE) and have dual (U.S./European) markings to ensure global acceptance.
Features and Benefits:
Available in open or enclosed forms (NEMA 1, 12/3R or 4)
Broad line offers wide array of contactors to meet most application needs from 5-500 hp at 460 volts.
Overload relays available in class 10, 20, and 30 with four set 40 function.
Manual reset only overload to meet automotive requirements
Finger and back of hands protected for greater safety
|
|
|
GE's advanced ASTAT Plus solid state soft starter is one of industry's most featured digital soft starters.
|
|
|
|
|
|
LS Meta-MEC Manual Motor Starters deliver more efficiency through various functions and compact design.
1. General
Meta-MEC MMSs are suitable for switching and rotecting three-phase induction motors of up to 45kW at 400VAC and for loads with rated currents of up to 100A.
2. Types
MMS32S, MMS32H, MMS63S, MMS63H, MMS100S, MMS100H
3. Ratings
- It covers all ratings up to 100A.
4. Function
- Protection of group installation
- Protection of circuits
- Motor protection & Starter protection
- Wide range of ambient temperature compensation
- Phase failure protection
5. Feature
- Width: 45mm for 32A, 55mm for 63A and 70mm for 100A
- Three position operator: ON-OFF-TRIP
- Complete range of common accessories
- Handle lock in the OFF position
- Class 10, 20 overload trip characteristics
- Trip test available
- Finger safe terminal
- DIN rail & Screw mounting
6. Standard
- The components fulfill the international standard IEC 60947.
- In U.S, the devices can be used as Manual Motor Starter in Group Installations according UL508.
The approval for UL508 Type E Combination Starter is under preparation.
|
|
Electronic soft-start modules 2.2...7.5 kW
Mechanical
¨ Low adjustable starting torque
¨ Reduced cost of drive components
Conveyor belts
¨ Falling over, banging or slipping of products, parcels etc. is eliminated
Electrical
¨ Reduced starting current (with SM, SM2X, SM2 only)
Applications
¨ Conveyor belts
¨ Packing equipment
¨ Long-travel drives for cranes
¨ Compressors
¨ Heat pumps
¨ Vibration transporters
¨ Machines with gearbox, belt or chain drives
¨ Special version for pole-change motors
Features
Switch-on torque and run-up voltage ramp separately adjustable.
¨ Module housing for mounting on 35 mm DIN rails. Very compact version with the width of a standard contactor (45 mm or 90 mm with SM2X)
¨ Terminals and potentiometers are well protected against accidental contact
¨ Easily retrofitted
¨ Can be used as a combined soft-start and injection brake using the electronic brake modules LEKTROMIK B1
|
|
|
|
|
|
Siemens - Safety Modules PROFIsafe
If it's a safety-oriented controller you need, you can't go wrong with the ET 200S Safety Motor Starter Solution PROFIsafe. Both standard and safe communication take place via a single bus system – PROFIBUS or PROFINET with PROFIsafe profile.
One bus system for both standard and safety signals instead of cumbersome wiring – this is just one of the many advantages which our ET 200S Safety Motor Starter Solution PROFIsafe features with regard to considerably reducing overhead during commissioning.
Furthermore, all sensors and actuators can be freely programmed within the distributed safety concept, whatever their I/O station.
Should you wish to switch off actuators selectively, the Motor Starters Failsafe come into play. If just a group switch off is required, then both standard and high-feature motor starters can be used.
Advantages at a glance
* Fail-safe communication via PROFIBUS/PROFINET with PROFIsafe profile
* Plant availability at levels never seen before – with maximum economic viability
* Up to Category 4 according to EN 954-1 – or up to SIL3 according to IEC 61508
* In addition, effective diagnostic functions and hot swapping help to reduce expensive downtimes
|
|
Piezo LEGS® - Demo kit
To get started and familiarize yourself with the Piezo LEGS® technology we offer several options of demo kits. This is the best way to test and verify the performance of the motors.
|
|
| ... products without technical information |
| |
|
|