Primary current: 10 A
Voltage: 240 V
The SKT safety switch is compact, lightweight, easy-to-install unit for small areas and is thus ideal for applications demanding small switches. Not just small, it is a smart safety switch with a separate ...
BERNSTEIN AG
Primary current: 10 A
Voltage: 240 V
... version of a safety switch featuring a separate actuator. Its dimensions (excluding the actuating head) correspond to EN 50047 requirements. The actuating head, which has two actuator ...
BERNSTEIN AG
Primary current: 10 A
Voltage: 240 V
Safety slave Low coded according to ISO 14119 (type 2) Safety switch with separate actuator Slim and short switch design AS-i status display ...
BERNSTEIN AG
... locking safety switches include a machine mounted switch and a guard mounted actuator that prevent access to an area by remaining locked together until the hazardous motion has come to ...
Primary current: 10 A
Voltage: 500, 600 V
Operating temperature: -25 °C - 80 °C
Functions - Type 2 interlock device with mechanically actuated position switch with low-coded actuator acc. to DIN EN ISO 14119 Mission time - 20 years, EN ISO 13849-1 B10d - 2,000,000 number of ...
Primary current: 10 A
Voltage: 500, 600 V
Operating temperature: -25 °C - 80 °C
... weight - 294 g Housing color - Gray Red Type of fastening - Through-hole mounting Type of cable entry - M20 x 1.5 Switch type - Interlock device without guard interlocking, ISO 14119 Switching principle - ...
Primary current: 0.25, 6, 4 A
Voltage: 250, 24, 230 V
Operating temperature: -40 °C
... 14119 Enclosure - thermoplastic, glass-fibre reinforced, impact resistant, self-extinguishing UL 94 V-0 Actuator - stainless steel 1.4301 Switch type - type 2 Coding level - low coding Degree of ...
steute Schaltgeräte
Primary current: 4 A
Voltage: 230, 24 V
• - Thermoplastic enclosure • - Double-insulated • - 52 mm x 90 mm x 30 mm • - Universal coding • - Long life • - High level of contact reliability with low voltages and currents • - Insensitive to soiling • - Slotted holes for ...
SCHMERSAL
Primary current: 4 A
Voltage: 24, 230 V
• - Thermoplastic enclosure • - Double-insulated • - Long life • - 52 mm x 75 mm x 30 mm • - Universal coding • - Large wiring compartment • - High level of contact reliability with low voltages and currents • - Slotted holes for ...
SCHMERSAL
Primary current: 4 A
Voltage: 24, 230 V
• - Thermoplastic enclosure • - Double-insulated • - Long life • - Small body • - Universal coding • - High level of contact reliability with low voltages and currents • - Insensitive to soiling • - 8 actuating planes
SCHMERSAL
Voltage: 230 V
... extraction force on the actuator, the PSENmech safety switches prevent the safety gate from being opened unintentionally. They comply with the standard EN ISO 14119 (protection against defeat) due to ...
Useful model for convenient installation Compact plastic-type casing Firm as well as mobile actuators A single cable access gland M16 x 1.5 Sluggish motion switching components having 2 or 3 connections
Primary current: 4, 1 A
Voltage: 12 V - 3,000 V
Operating temperature: -25 °C - 80 °C
• Housing according to EN 50041 • Cable entry M20 x 1.5 Guard locking type VSE Open-circuit current principle, guard locking by applying voltage to the solenoid. Release by spring force. Switching element 2131H Slow-action ...
EUCHNER GmbH + Co. KG
Primary current: 4, 1 A
Voltage: 12 V - 3,000 V
Operating temperature: -25 °C - 80 °C
... locking by spring force. Release by applying voltage to the solenoid. Switching elements SK For monitoring the door/actuator position ÜK For monitoring the guard locking (built-in solenoid) 2131H Slow-action ...
EUCHNER GmbH + Co. KG
Primary current: 1, 4 mA
Voltage: 12, 24, 230, 3 V
Operating temperature: -20 °C - 55 °C
• Actuating head made of metal • Auxiliary release on the front Solenoid operating voltage AC/DC 24 V +10%, -15% Guard locking type STM1 Closed-circuit current principle, guard locking by spring force. Release by applying voltage ...
EUCHNER GmbH + Co. KG
Primary current: 0.2, 1 A
Voltage: 1 V - 24 V
Diameter / length: 25 mm
... surface • Long life (50 million cycles) • Ring or Dot illumination • Sealed to IP68 or IP69K (switch mounted on panel) Advantages Langir Piezo switches are based on a solid-state output allowing ...
FS series safety switches with separate actuator with lock Protection degree: IP67 according to EN 60529 Power: 24 Vac/dc (D working method) Housing: Thermoplastic resin ...
Pizzato Elettrica
... the actuator on the guard and interlock switch on the machine. Equipped with two actuator entry slots. Double insulation structure 30 different numbers are available for key, so that ...
Operating temperature: -40 °C - 70 °C
Width: 24 mm
Height: 24 mm
2 POSITIONS Stay Put 2 Positions (1-2), Stay Put Spring Return 2 Positions (1-2), Spring Return (2 to 1) 3 POSITIONS Stay Put 3 Positions (1-0-2), Stay Put Spring Return 3 Positions (1-0-2), Spring Return (to 0) Spring ...
DOMO
Primary current: 3 A
Voltage: 24, 110, 230 V
Operating temperature: -25 °C - 50 °C
... with direct food splash and cleaning found in the tough applications of the Food Processing Industries. Choice between 4 actuator types: A = Standard, F = Flat, HF = Heavy Duty Flexible, HFH = Heavy Duty Flexible Hygienic Features: ...
Idem Safety Switches
Omron Scientific Technologies, Inc. safety switches are designed to work together with hinged, sliding, or lift-off guards and barriers. When the guard is opened, the power supply to the machine is disconnected
Safety switch with a separate actuator Miniature size, 75 x 25 x 29mm housing 8 possible actuator entry points Contacts: 2 N/C or 1N/C, 1N/O Protection category IP67
Zander GmbH & Co. KG, Hermann
Operating temperature: -40 °C - 85 °C
22 MM CONTINUOUS TOUCH METAL SWITCH, ONE COLOR LED ILLUMINATED, FLAT HEAD STAINLESS STEEL, LED ACTIVATED VIA EXTERNAL CONTROLER Continuous Touch Metal Switch One piece solid metal switch ...
You can use safety switches with a separate actuator to monitor protective isolating devices on sliding doors, swing doors or detachable paneling, for example. These safety switches ...
... the data line (170 mA max. current consumption of the magnet) through direct integration of safety switches with tumbler 3SF13...-1BA4 position switches are suitable for series connection for protective ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining