P u r g a s complete purification series
In order to make natural gas suitable for utilisation as fuel in motor vehicles, it is essential to remove suspended solid particles and to ensure that the gas is dry (i.e. that it contains no water)! On the one hand this ensures reliable operation of the vehicles by preventing clogging and corrosion of vital vehicle components such as the fuel system and the fuel tank.
On the other hand, natural gas fuel filling stations are not subject to disturbances, for example at professional compressor intakes or due to freezing at the fuel pumps, so that availability is ensured around the clock.
Meet the reqirements of ISO 15403:2000(E). http://www.iso.org
ZANDER offers system solutions from 16 up to 350 bar. Capacity 35m³/h up to 2500 m³/h.
Manufactured by the specifications ISO 9001 and ISO 14000, the design of the delivered absorbers and professional filters is technically free from oil and grease, for applications involving technical gases of the fluid group 1 according to the pressurised equipment directive (DRG 97/23/EC). This ZANDER system solution dependably fulfils the standard for natural gas quality according to ISO 15403:2000(E) as well as compliance with the European directives for explosion protection according to ATEX (94/9/EG)
|
|
CNG Series
Twin Tower Natural Gas Industrial dryers
CNG Series twin tower industrial purification systems are completely self-contained, fully automatic, heat reactivated, closed-loop professional blower purge desiccant dryers. Located at the gas inlet of the booster compressor manufacturer, they are designed to remove water vapor from Compressed Natural Gas. Using molecular sieve as the drying media, these systems will continuously dry CNG down to a pressure dew point as low as -100°F with residual moisture levels as low as 0.04 lbs. per mmscf.
Specifically engineered for large flow (>200 scfm) heavy-duty NGV fleet refueling applications.
Specially formulated molecular sieve desiccant for minimal odorant fading and low-pressure drop.
Full-ported, poppet type non-lubricated cocks for reliable operation and long life.
Down-flow drying results in less fluidization & longer desiccant life.
Closed-loop convection regeneration-no gas lost to purge and prolonged desiccant life.
|
|
There are three hydrogen generator models in the HG2000 Series, offering outputs of 200 to 600 Nml/min and gas purity ratings in excess of 99.9995%. Thanks to their compact dimensions, these units can easily be positioned near the analysers they feed.
These industrial generators are equipped with a microprocessor control system, a liquid industrial crystal display to inform the operator of generator status in real time, and a membrane keyboard for setting main gas delivery parameters. HG2000 Series reformers are also equipped with an effective alarm system to warn the operator of any system malfunctions.
|
|
As Gas Chromatograph users will probably confirm, little has changed in the past decades in the way hydrogen gas is used in the laboratory. Now that picture is set to change, thanks to a remarkable multi-disciplinary gas generator manufactured by Parker Balston. Their new paradigm solution for generating hydrogen in laboratories is so easy to use that it could potentially save thousands of Euros a year in expensive downtime and installation costs.
Four different models have been upgraded to the 100, 165, 260 and 510 ml/min units producing high purity hydrogen, 99.9999% at up to 6.89 bar. Special features include an advanced PEM electrochemical cell protection system with microprocessor controls, a unique water hydration circulation purification system. This is also complimented by USB capability with professional software options for remote monitoring and control, blue intensity back lighted display for simple operator use with professional touch screen visuals for system status checks, Automatic water fill options, and data logging performance controls for preventative maintenance with reporting tools for use in regulated environments where system validations are required.
These professional generators will allow GC (Gas Chromatograph) users to supply, control, and automate all hydrogen gas supplies. A single generator can support up to as many as 13 instruments with high purity hydrogen.
Other applications include fuel gases for total hydrocarbon industrial analyzers, supply gases for hydrogenation reactors, hydrogen for pilot scale fuel batteries assays and hydrogen for collision reaction gases.
Each generator is available as standard with a two-year warranty emphasizing the quality and reliability
Parker Balston is the worldwide leader in separation and filtration technologies, and offers a broad range of analytical gas generators to meet your specific analytical instrument requirements. All products are backed by a fully staffed field sales and service organization.
|
|
Claind’s nitrogen generators satisfy all laboratory analysis and industrial process needs with very few exceptions.
The range includes compact professional generators with built-in oil-free compressors suppliers, medium and high pressure generators for industrial applications, and special generators for OEM applications.
Claind’s nitrogen generators are based on PSA (Pressure Swing Adsorption) technology for maximum reliability and gas quality. Claind has also patented the Fast Purity system, the most significant innovation in the world of PSA technology in recent years. |
|
| The combination of these technologies produces a continuous on-demand supply of pure nitrogen. Typical applications include nebulizer gases, curtain gases, source gases, chemical and solvent evaporation, instrument purge and supply, evaporative light scattering detector use and sparging. |
|
Hydrogen generator HG2000
There are three hydrogen generator models in the HG2000 Series, offering outputs of 200 to 600 Nl/min and gas purity ratings in excess of 99.9995%. Thanks to their compact dimensions, these units can easily be positioned near the analysers they feed.
These professional generators are equipped with a microprocessor control system, a liquid industrial crystal display to inform the operator of generator status in real time, and a membrane keyboard for setting main gas delivery parameters. HG2000 Series reformers are also equipped with an effective alarm system to warn the operator of any system malfunctions.
|
|
Dimensioning range from 26 Nm³/h up to 320 Nm³/h at purity
up to 99.5 %.
Due to the development of special fibres filtrating pneumatics very efficiently, this plant achieves unchanging purity grades.
The IMT-MN is a cost-saving alternative to the traditional supply
by gas-bundles or tank installations.
As an option these plants are available in stainless steel or ATEX
dessign. |
|
Oxygen from the socket.
Oxygen supply without extensive logistics at purity range up to 40 %.
These membrane industrial generators provide a continuous supply in the
capacity range of 150 ltrs./min. up to 2000 ltrs./min. at O2 purity
grades from 30 - 40 %. |
|
Claind’s nitrogen generators satisfy all laboratory analysis and industrial process needs with very few exceptions.
The range includes compact industrial generators with built-in oil-free compressors manufacturer, medium and high pressure generators for industrial applications, and special generators for OEM applications.
Claind’s nitrogen generators are based on PSA (Pressure Swing Adsorption) technology for maximum reliability and gas quality. Claind has also patented the Fast Purity system, the most significant innovation in the world of PSA technology in recent years. |
|
Nitrogen generation up to 99,9999 / 6.0 purity with "Pressure Swing Adsorption".
The technology of Pressure Swing Adsorption provides for nitrogen provisioning at purity grades of up to 99,9999 % and capacities
ranging from 0,5 - 2.000 Nm³/h.
Following options are available amongst others:
- pressure booster up to 300 bar
- flow meter
- special voltage design
- pressure dew point indicator
- remote inquiry.
All units of the PN model range are equipped with touch panel
and USB port. |
|
The LASERGAS nitrogen generator is a truly high range industrial generator thanks to sophisticated technology and exceptional performance.
This unique gas generator is capable of producing nitrogen at very high pressure. It is available in various versions with different outputs, purity and pressure ratings.
The LASERGAS nitrogen generator can be used in any area of industry requiring a medium or high pressure nitrogen supply, or whenever intermittent demand requires large reserves of nitrogen to be kept ready for rapid consumption. |
|
‘Plug and Play’ Nitrogen Generator for LC/MS
The Parker Balston® NitroFlow Lab is a self contained generator that produces up to 32 lpm of pure LC/MS grade nitrogen at pressures up to 8 bar. It produces nitrogen by utilizing a combination of compressors manufacturer, filtration, and membrane separation technologies. High and low pressure compressors carefully matched to hollow fibre membranes separate the clean air into a concentrated nitrogen stream.
The combination of these technologies produces a continuous on-demand supply of pure nitrogen. Typical applications include LC/MS/MS nebulizer gases for APCI and ESI, ELSD, Turbo Vaps and chemical solvent evaporation. The NitroFlow Lab has been tried and tested by all the major LC/MS manufactures.
The unique combination of the dual compressor generator ensures that the NitroFlow Lab has several unique technical advantages over all other existing LC/MS Nitrogen generators.
Nitrogen is produced at low pressure and then compressed to 8 bar. This ensures minimal maintenance of the system with no compressed air filter replacements or condensate. The compressor life is guaranteed under the Parker Balston warranty for 8000 continuous running hours, the longest currently available on the market.
Parker Balston is the worldwide leader in separation and filtration technologies, and offers a broad range of analytical gas professional generators to meet your specific analytical instrument requirements. All products are backed by a fully staffed field sales and service organization.
|
|
Performance: max. 900 ltrs./h
Purity: max. 95 %
Supply pressure: 10 bar
Car tyres: max. 8 pces./h
Dimensions: 900x650x120cm (HxWxD)
Weight: 20 kg
- Industrial strainers ensure adequate filtration of compressed air
- minimal compressed air consumption
- Installation operative after connection to compressed air! |
|
Parker has developed a nitrogen generation tyre compression unit, which have been specially designed for delivering high quality compressed nitrogen into tyres. Called TyreSaver and Truck TyreSaver the new range offers unsurpassed levels of service life and potential savings of $100'000 on tyre maintenance and downtime in a one year period. This means, a truck tyre inflated with nitrogen could easily go an extra 50'000 miles before the tyres need servicing.
The units are designed for filling tyres with nitrogen supplying the purity required to keep the tyres at constant pressure. Equipped for connection to an external nitrogen storage vessel or directly to the airline, the professional generator will automatically switch on and off depending on the nitrogen demand.
The pneumatics can be sourced either from a central system, or from a dedicated compresser. High quality compressed manufacturers of air filtration, coarse, fine and carbon professional filters protect the membranes ensuring long membrane life.
Nitrogen in tyres is a concept which has been adopted by road haulage firms in the United States and Canada, who have been using Truck TyreSaver for the last three years. Moreover the concept is widely used in the Motorsport industry and NASA for a number of years, one factor behind this is Nitrogen's low risk of combustion. |
|
Parker Balston® SOURCE LCMS-5000 Series is now available for Applied BioSystems MDS Sciex API-LC/MS users
The Parker Balston® SOURCE-LCMS-5000 is a visually integrated and functionally modular LC/MS gas generation system which produces high purity nitrogen, zero air and exhaust pumping gases for all Applied Biosystems – MDS Sciex LC/MS/MS instruments.
It produces nitrogen, zero air and pump exhaust air by utilizing a combination of a compressor with filtration, catalysts and membrane separation technologies. An integrated low-maintenance compressed air supply is filtered by high efficiency coalescing filters removing all contaminants down to 0.01 micron. Hollow fiber membranes subsequently divide the clean air into a concentrated nitrogen stream. The zero air is produced by catalytic oxidation which converts the hydrocarbons. A passive hollow-fiber dehydration membrane is used to create the exhaust pump gas.
The integrated Scroll compressor is ‘whisper’ quite at only 48 dBA and is supplied as standard with a 10,000 hour / 3 year warranty. Low maintenance and reliable this offers the best compressor warranty currently available on the market.
Parker Balston is the worldwide leader in separation and filtration technologies, and offers a broad range of analytical gas industrial generators to meet your specific analytical instrument requirements. All products are backed by a fully staffed field sales and service organization.
|
|
Oxygen PSA range
Oxygen production by use of "Pressure Swing Adsorption"
technology with purity rates up to 99,5 % and capacities
ranging from 0,5 - 2.000 Nm³/h.
Following options are available:
- alert function
- analyser units
- operation-hour professional counter
- pressure booster up to 300 bar
- touch panel
- SMS message system
- flow meter
- special voltage design. |
|
The H2 MAX3 Series is designed to satisfy the needs of industry.
This series of manufacturer of hydrogen generators is a true ambassador for Italian innovation and technology. Claind is the only Italian manufacturer of pressure electrolysis hydrogen industrial generators capable of conforming to the strictest CE international safety standards (ATEX, PED).
Technical specifications
Output: from 0.5 to 30 Nm3/h
Delivery pressure: 15 bar (without auxiliary compressors manufacturer)
Gas purity: 99.7% without deoxo, 99.999% with deoxo
CE certified (ATEX, PED)
BENEFITS
Safety: maximum operating safety.
Purity: Oxygen levels below 0.2% O2.
APPLICATIONS
Refuelling stations for hydrogen fuelled vehicles
Energy storage systems and research into renewable energy sources like peak shaving, PROFESSIONAL UPS, and completely off-grid systems.
Industrial processes like annealing, noble metal brazing, cooling of nuclear and other electrical power stations, food processing and pharmaceuticals.
|
|
Distributed Energy Systems' StableFlow™ Hydrogen Professional control System is a breakthrough product allowing a power plant to actively control professional generator casing hydrogen purity, pressure and dew point.
StableFlow Hydrogen Control Systems integrate into your current hydrogen supply and automatically control pressure, purity and dew point. Actively controlling
hydrogen at optimum professional levels in your hydrogen cooled generator that will:
• Optimize Fuel Efficiency
• Maximize Generator Capacity
• Extend Generator Life
StableFlow Hydrogen Control Systems are designed for simple installation and do not require a generator outage. |
|
Proton Exchange Membrane Compact
Manufacturer of hydrogen generators
- High purity (99.999+ %)
- Process pressure
- Minimizes hydrogen inventory
- No caustic electrolytes, asbestos free
- Reliable, compact, automatic control
Production rates: .5 - 1 Nm3/h (19 to 38 scf/h)
Distributed Energy Systems makes Proton Exchange Membrane (PEM) hydrogen industrial generators the new standard for on-site hydrogen production. Related PEM products are already recognized as the technology of choice for automotive fuel batteries. HOGEN® hydrogen generators are available for broad commercial use.
|
|
The Peak Scientific Hydrogen power generator delivers high purity gas, with reliability and safety built in to every component.
The 'cylinderfree' systems have many unique features, making them the preferred choice of laboratories requiring reliability and quality.
Using ION exchange membrane technology, originally developed for NASA, the professional generator required only deionised water (loaded automatically) to produce a constant supply of hydrogen. |
|
TELEDYNE ENERGY SYSTEMS, INC. manufactures hydrogen generation systems designed for on-site, automatically controlled, ultra-pure hydrogen product gas generation. Delivery flows range from 1.1 nm3/hr (20 SLM) up to 56 nm3/hr (1,000 SLM) with 99.9998% purity. The industrial generators also produce oxygen as a byproduct of the water electrolysis process.
The hydrogen generation are fully assembled, skid mounted and operationally tested prior to shipment to facilitate ease of installation and commissioning. System design can also be provided to include compression and storage solutions specific to your application.
TELEDYNE ENERGY SYSTEMS, INC. hydrogen generators are currently used in power station, chemical plant, semiconductor, argon purification, metals processing, float glass, fiber optic, research laboratory, fuel cell testing, and hydrogen fueling applications throughout the world.
|
|
KOFLOC NT SERIES
KOFLOC Nitrogen Gas Industrial generator MNT SERIES is a medium size nitrogen generator manufacturers with a status messenger function as a standard feature. The optional touch-panel control allows professional timer operation arrange by day of the week and error logging. The adsorbent (molecular sieving carbon selectively adsorb a large amounts of professional oxygen under high-pressure condition, quickly removing oxygen carbon dioxide and moisture out of air, leaving only the high purity nitrogen gas as the final product. The adsorbent material releases oxygen when depressurized. High-purity nitrogen gas can be produced continuously by PSA (pressure swing absorption), which is a method of alternately pressurizing 2 adsorption vessels.
FEATURES
♦ Fully automatic
♦ Compact
♦ High-purity and dry (–55˚C or less) nitrogen gas can be obtained
♦ Oxygen sensor, gas flow meter, flow regulator valve and the messenger function as standard features
♦ Optional touch-panel for timer-operation and error-logging
APPLICATIONS
* Substitution for nitrogen gas cylinders
* For heat treatment processes
* Semiconductor processes
* CA storage gas for fruits and vegetables
* Non-oxidization industrial seal gas
* Explosion-proof or rust-prevention gas
* Seal gas for shipping
* Blanket gas for synthetic fibers and melted spinning |
|
| A full range of laboratory gas industrial generators are available including UHP Hydrogen, Nitrogen, Zero Air and CO2 Free Air. |
|
HOGEN GC reformers provide ultra-pure (99.9999%) pure hydrogen for a wide variety of laboratory and small scale industrial applications such as:
- Carrier gas for Gas Chromatographs (GCs)
- Fuel gas for flame ionization detectors (FID¹s) used with GCs
- Fuel gas for Trace Hydrocarbon Industrial analyzers
- Hall detector reaction gas
- Plus hydrogen for other precision instruments and chemical research |
|
The domnick hunter MAXIGAS range of nitrogen generators has been developed to allow users to produce their own supply of nitrogen gas on-site, without the need for traditional high pressure professional cylinder or liquefied gas supply.
A domnick hunter Maxigas nitrogen generator can very easily form the basis of a complete central nitrogen supply, furnishing multiple analytical instruments with clean, dry nitrogen.
The MAXIGAS professional generators produce nitrogen gas from a virtually free resource %u2013 air. Designed to operate from compressed air, the generators deliver a continuous, uninterrupted supply of nitrogen gas at purity from 97%-99.999%.
The MAXIGAS systems offer the safest, most convenient and economic source of nitrogen available. The compact, modular design allows easy upgrading of the system as production capacity expands.
At 10 ppm oxygen content flow rates vary from 1.3 Nm3/hr to 6.5 Nm3/hr. At 1% the corresponding flow rates available are 11.8 Nm3/hr %u2013 59.1 Nm3/hr.
|
|
|