The CT224 consists of a 12-Channel Temperature Monitor and MincoSoft™ CT224 Software. It is the next generation in temperature monitoring equipment from Minco designed to meet the needs of electric machinery protection. The 12-channel scanning capability, standard RS485/RS232 interface and Windows-compatible software utility for system configuration and data logging provide overtemperature and undertemperature protection and critical feedback to safeguard expensive machinery.
|
|
|
|
|
|
Multi-funcitonal Thermocouple Thermometer ( DTM-3105 )
Thermocouple Thermometer Model DTM-3105
FUNCTION:
ON/OFF, HOLD/TEST, °F/°C, MIN/MAX ( °F/°C) MEMORY RECALLING
* Carrying Case and 4 TC probes Included
PROBE MODEL NO.:
1. DTM-3105-TPK4 Surface probe (230 mm)
2. DTM-3105-TPK5 Air probe (235 mm)
3. DTM-3105-TPK03R Round head immersion probe (130mm)
4. DTM-3105-TPK03S Pin point head immersion probe(125 mm)
FEATURES:
Rubber coated product case
High degree of accuracy
Extra EVA box for easy and protective storage
Four probes included
Comprehensive and variety use for different object (e.g. surface, semi-solid, air)
Large LCD display
MEASUREMENT RANGE
-100°C ~ +300°C or -148°F ~ + 572°F
RESOLUTION:
0.1° for -199.9° ~ +300.0°
ACCURACY:
± 2°C from -200°C ~ -50°C (or 4°F from -328°F ~ -58°F)
± 1°C from -49°C ~ +300°C (or 1.8°F from -56.2°F ~ +572°F)
Accuracy is specified for operating temperatures over the range of 18°C to 28°C (64°F to 82°F). The basic accuracy specification does not include the error of the thermocouple probe.
|
|
Limit value monitoring devices
SG-mc Digital
Limit Indicator
35 mm DIN - rail mounting
* Universal sensor input
* (Pt 100,TC, 0 / 4...20mA, 0...10VDC)
* Alarmcontact free programmable with latch function or without latch function.
* Latch-reset by mini-switch or by power on/off
* Easy handling
|
|
|
|
|
|
The LumaSense Accufiber®TR solution provides temperature monitoring with automatic emissivity correction. Emissivity changes are due to changing material properties during certain types of material deposition or processing. For specular (smooth) surfaces, the deposition surface’s emissivity can be calculated from its reflectance. By constantly measuring this reflectance, the AccufiberTR instrument can automatically perform the emissivity correction in-situ and calculate the surface’s true temperature.
AccufiberTR seamlessly integrates ultra precise reflectance measurements with LumaSense’s class leading, lowest signal-to-noise ratio radiation detectors. If the n and k values are known for the materials, then the amplitude and periodicity of the thin film reflectance (often referred to as “fringes”) at specific wavelengths can be used to calculate film thickness. For thin films, it is critical to use both the highest quality measurement systems and shorter wavelengths to offer “resolution” into the film’s fringes to monitor film thickness.
|
|
Turbine Sentry - System Overview
An overview of the complete system and how this system is of benefit to gas turbine operators.
A typical system comprises three parts:
Blade Sentry - Measurement Pyrometer
The non-contact thermometer is mounted through the gas turbine casing and measures the temperatures of individual rotor blades.
Rotor Sentry - Data Acquisition System
The DAS logs individual blade temperature readings taken by the measurement pyrometers, samples and processes the data for use by the data analysis software, Data Sentry.
Data Sentry - Data Analysis Software
This powerful pc-based software utility has all the tools and functions necessary to obtain a complete picture of how efficiently the gas turbine is running, as well as identifying potential problems at an early stage.
|
|
| ... products without technical information |
| |
The powerful indicator N1500 offers among its universal input and the 2 relay outputs for the monitoring of the threshold values many other functions. The Min.- and Max.-values can be prompted with just a keystroke. Also there is a Hold and a Peak-Hold Function whose readouts can be deleted using either the function key or the digital input. The high tact frequency of 15 measurements/second (5 measurements/second when using linear input, thermocouples or Pt100) allows the N1500 indicator to monitor fast processes. It offers also the possibility to linearise the measurement signal when using non-linear input signals (mV, V, mA).
Features:
- Universal input
- Linearization of mV, V, mA signals
- 2 Relay outputs
- 6 Alarm features
- Voltage output 24 VDC for external 2-wire transmitter
- Memory for MAX and MIN values, hold and peak features
See more information in our shop:
***www.temperature-shop.de***
|
|
Enhanced indicator
Double input Indicator - Transmitter with four addressable alarms
1/8 DIN 96x48
Universal input for temperature sensors, mA, mV, Volt, IR, custom
High level second input 0/4...20 mA, 0/1...5, 0...10 V
3 digital inputs
3 SPST relays NO, 1 SPDT relay
0/4...20 mA retransmission output
4 addressable alarms with delay, latching and blocking functions
ISA sequence on alarms
Display of MIN, MAX value
Hold and temporized hold to display peaks
Dedicated alarm acknowledge key
5 digits 2 colors display with different combinations
RS 485 serial communications
Power supply 100...240 Vac, 24 Vac,dc
Transmitter power supply
IP65 front panel protection
|
|
|
|
|
|
MOLTEN METAL TEMPERATURE INDICATOR
PRODUCT DESCRIPTION:
Libratherm offers microcontroller based Molten Metal Temperature Indicator model LMI-2010, which is designed to accurately measure temperature of the molten metals, both ferrous and non ferrous. The measurement of this temperature is a critical process, since the expendable thermocouple is dipped for merely 3 to 4 seconds and then withdrawn. In this short measurement time, the operator is guided through the measurement cycle by audio/visual alarms for thermocouple continuity, measurement in progress and measurement over. Any error in measurement or thermocouple open condition is also immediately detected by activating the audio/visual alarm.
User can select the desired type of thermocouple (either K, R, S, or B type, (depending upon the measuring range from 1200 to 1800oC), and can also set other parameters using front panel key board. During measurement, the indicator ignores the slag temperature and the Average or Plateau reading is determined using the advanced algorithm and the same is latched and displayed on the bright 7 segment 2” LED display. This reading can also be displayed on 4” remote display LRU-2010 and can be logged on to a computer using serial RS485 MODBUS RTU protocol for recording and analysis purpose. Libratherm offers supporting window based software.
|
|
Various sizes displays with or without alarm functions.
Different mounting types f.ex wall or panel mounting.
|
|
- Big keys for use with gloves
- Programmable characteristic curve end points (up to 24 control points)
MIN/MAX value detection,
- Display-Hold
- Auxiliary power output for measuring transducer/sensor
- Optocoupler or relay outputs
- Programmable limit values
- Optional: with serial interface
|
|
|
The Tecal Accu-Temp is a good choice for use as a laboratory grade reference thermometer. It's available in a single or dual channel model, along with direct temperature readout in degrees F, C and ohms. Combine the Tecal Accu-Temp with one of our secondary standard PRT's for a high accuracy temperature measurement system. Don't rely on battery operated, low accuracy hand-held model PRT indicators for your critical temperature measurements.
|
|
S1305
Format: 96x96 mm (1/4 DIN)
Installation depth: 122 mm
The universal monitoring instrument
* Instrument with 3 limit contacts
* Universal Input (Pt 100, TC, 0 / 4...20mA, 0...10Vdc)
* Easy handling
|
|
| ... products without technical information |
| |
With their constant processing design, CSC type continuous screen changers are able to meet the most stringent quality requirements for melt filtration. The type HSC, FSC and DSC discontinuous screen changers are a simple, robust, and affordable alternative for applications where a short interruption in the melt flow is possible for making screen changes.
The DV continuous divert and dump valve was developed specifically to meet the requirements of underwater pelletizing. It features a unique design that provides bump-less changeovers and eliminates the possibility of a deadhead condition.
|
|
Xaloy Screen Changers
Xaloy, the worldwide leader in melt filtration, offers a broad of range screen changers engineered for reliability, productivity and cost-effectiveness in virtually any extrusion processing environment.
* Leak-free operation
* Easy maintenance
* Simple, safe operation
* Maximum throughput
* Minimum pressure drop
Different types of Xaloy changers are available to fill your cost-performance need:
Manual changers: EM series. Our simplest, lowest-cost changers.
Pneumatic changers: XP series. Use the plant’s air supply to index the slide plate.
Hydraulic changers: EH series. Fast hydraulic actuation allows filter changes without shutting down the extruder.
Continuous changers: DBC series. Automatically maintain filter performance without production interruption.
High-capacity changers: SPC series. Can filter polymer at rates from 6,000 to 60,000 lb/h (approx 2700 to 27,000 kg/h) or more.
|
|
Double- plate hydrulic screen changer with double working position
Double-plate type screen changer realizes non-stopping screen changing by alternating two plates.with double filtering areas, it is suitable for high output extrusion lines from 500kg/h to 2000g/h.
Characteristic
Double filter working alternatively, fast screen changing, easy production and maintainance.
Rapid screen changing time: within 2 sec.
Top and bottom copper ring close sealing on Main body and water sealing function, strengthens body sealing effect.
Ellipse shape filtering holes, larger filtering area.
High precision electronic ruler control,short changing time, hydraulic control system and secure operation.
Pressure range : 25—30Mpa, temperature under 300℃, keep normal function
|
|
Double working position hydrualic screen changer of double –pillar type
Characteristic
Large filtering area, applicable to extrution product of a wide range of polymers.
Good sealing system,ensure perfect sealing effect.
air exhausting system is the most outstanding performance characteristic.
Standard type is 70-180mm. Other diameter can be tailor made.
Outside cover brings good appearance and safe operation .
|
|
As the yougest generation among JCtimes group, stress on development and application on extrusion related equipment market, keep making innovation, has added great power to this team.
Features
It is designed with soft sealing system, matched with extruders of different specifications, it’s applicable to process with most polymers, at high output.
Screen changing time is within 2 seconds, and screening area covers from Φ30—Φ250.
With highly precise design, the screen has very good abrasive resisting, high pressure performance, so as to ensure large effective filtering area and enhance filtering effect.
It works well even under the high temperature of 300℃ and high pressure of 25—30Mpa.
Equipped with the secure cover, safty of the operator is completely guaranteed which well reflecting the ergonomic designing philosophy.
|
|
Separator screens are conveying nstallations using directional vibration to handle castings carefully and separate them from loose sand / lumps at the same time. The standard use of these machines is continuous operation for serial products. With this facilitiy the sand shake out is recycled in a downstream treatment plant and returned to the process.
Features
- High wear-resistance
- Rugged design
- Low overall height
- Long service life
Benefits
- Low operating costs
- Small footprint
- High operational reliability
- Long service life
- Good value for money
|
|
|
|