T400 Elite
Fixed Trip Point Bearing Temperature Monitoring System
Microprocessor controlled unit - monitors 8 zones with up to 6 bearings in each zone
Status LED's provide quick location of the hot bearing condition
Easy installation – no set up!
Extensive range of PTC sensors available from 50∫C to 120∫
Sensors replace existing grease points without loss of maintenance function
Alarm mute - with automatic time delayed reactivation
|
|
T500 Elite - HotBus system
- Serial Network for Continuous Remote Sensor Monitoring
- Preventative maintenance tool fully compatible with existing systems
- Accepts input signals from a total of 256 sensors
- User adjustable trip-points for alarm & shut-down
- “BUS VIEW” Easy-to-use graphical monitoring software available
- Utilises the "HotBus" communications system
|
|
Control your storage & incubation conditions
Guarantee your products quality
Ensure a complete traceability of the monitored parameters
LABGUARD 2 is THE solution...
Simple and wireless, it measures and records
in real time the different parameters : temperature, humidity, pressure, CO2...
and manages alarm in real time.
In one screen and a few clicks only...
|
|
|
The CT224 consists of a 12-Channel Temperature Monitor and MincoSoft™ CT224 Software. It is the next generation in temperature monitoring equipment from Minco designed to meet the needs of electric machinery protection. The 12-channel scanning capability, standard RS485/RS232 interface and Windows-compatible software utility for system configuration and data logging provide overtemperature and undertemperature protection and critical feedback to safeguard expensive machinery.
|
|
|
|
|
|
Multi-funcitonal Thermocouple Thermometer ( DTM-3105 )
Thermocouple Thermometer Model DTM-3105
FUNCTION:
ON/OFF, HOLD/TEST, °F/°C, MIN/MAX ( °F/°C) MEMORY RECALLING
* Carrying Case and 4 TC probes Included
PROBE MODEL NO.:
1. DTM-3105-TPK4 Surface probe (230 mm)
2. DTM-3105-TPK5 Air probe (235 mm)
3. DTM-3105-TPK03R Round head immersion probe (130mm)
4. DTM-3105-TPK03S Pin point head immersion probe(125 mm)
FEATURES:
Rubber coated product case
High degree of accuracy
Extra EVA box for easy and protective storage
Four probes included
Comprehensive and variety use for different object (e.g. surface, semi-solid, air)
Large LCD display
MEASUREMENT RANGE
-100°C ~ +300°C or -148°F ~ + 572°F
RESOLUTION:
0.1° for -199.9° ~ +300.0°
ACCURACY:
± 2°C from -200°C ~ -50°C (or 4°F from -328°F ~ -58°F)
± 1°C from -49°C ~ +300°C (or 1.8°F from -56.2°F ~ +572°F)
Accuracy is specified for operating temperatures over the range of 18°C to 28°C (64°F to 82°F). The basic accuracy specification does not include the error of the thermocouple probe.
|
|
Limit value monitoring devices
SG-mc Digital
Limit Indicator
35 mm DIN - rail mounting
* Universal sensor input
* (Pt 100,TC, 0 / 4...20mA, 0...10VDC)
* Alarmcontact free programmable with latch function or without latch function.
* Latch-reset by mini-switch or by power on/off
* Easy handling
|
|
|
|
|
|
The LumaSense Accufiber®TR solution provides temperature monitoring with automatic emissivity correction. Emissivity changes are due to changing material properties during certain types of material deposition or processing. For specular (smooth) surfaces, the deposition surface’s emissivity can be calculated from its reflectance. By constantly measuring this reflectance, the AccufiberTR instrument can automatically perform the emissivity correction in-situ and calculate the surface’s true temperature.
AccufiberTR seamlessly integrates ultra precise reflectance measurements with LumaSense’s class leading, lowest signal-to-noise ratio radiation detectors. If the n and k values are known for the materials, then the amplitude and periodicity of the thin film reflectance (often referred to as “fringes”) at specific wavelengths can be used to calculate film thickness. For thin films, it is critical to use both the highest quality measurement systems and shorter wavelengths to offer “resolution” into the film’s fringes to monitor film thickness.
|
|
Turbine Sentry - System Overview
An overview of the complete system and how this system is of benefit to gas turbine operators.
A typical system comprises three parts:
Blade Sentry - Measurement Pyrometer
The non-contact thermometer is mounted through the gas turbine casing and measures the temperatures of individual rotor blades.
Rotor Sentry - Data Acquisition System
The DAS logs individual blade temperature readings taken by the measurement pyrometers, samples and processes the data for use by the data analysis software, Data Sentry.
Data Sentry - Data Analysis Software
This powerful pc-based software utility has all the tools and functions necessary to obtain a complete picture of how efficiently the gas turbine is running, as well as identifying potential problems at an early stage.
|
|
| ... products without technical information |
| |
|
In line high speed color monitoring system designed to monitor transluscent color applications. The ColorMax-View works at speeds of 2,000 parts per seconds and provides RGB color values in analog and digital forms.
|
|
|
The CA-210 LCD Color Analyzer is Konica Minolta's "next generation" color analyzer designed to measure color luminance, gamma characteristic and flicker on various types of Flat Panel Displays including LCD and EL. Faster than previous generation analyzers, the CA-210's measurement of luminance and chromaticity at up to 20 times/second makes it ideal in high production environments. (AND it can simultaneously measure up to five points on the screen. ) The CA-210's special optical design limits acceptance angle to within ± 2.5 degrees, thus eliminating the influence of the LCD's viewing angle dependency. Matrix calibration allows for high measurement of LCD displays that provide colors through additive mixing of three monochrome colors (R,G,B). A new low luminance capability enables measurements as low as 0.1cd/m2
|
|
Verify the opacity of containers with on-line, high-speed, accurate and reliable measurements. The OPAX-1000™ combines proven sensor technology with innovative hardware to provide an easy-to-use system to measure light transmission in a wide variety of applications.
Many products require packaging designed to protect the contents from the damaging effects of light. Establishing pass/fail criteria for minimum opacity of these containers and providing on-line measurement eliminates defects and allows real-time quality control of these processes. The OPAX-1000™ provides a reliable solution, allowing you to monitor every container, and identify and remove containers with low opacity.
|
|
The module PW0049 is a stand-alone measuring device which is conceived for the absolute measurement of self-illuminating objects.
Its function is to reproduce the CIE 1931 2° CMF's as precisely as possible. The resulting Tristimulus measuring values X, Y, Z form the basis of most of the common color spaces used today.
|
|
|
Gentec-EO offers OEM customers the highest flexibility so that you make no compromise. Whether you want a different housing, a specific sensitivity or another output connector, we have a solution for you. We will adjust existing models or design a whole new detector to best meet your needs.
|
|
| ... products without technical information |
| |
Online Monitoring System for Oil and Hydraulic Fluid
OLMS 4
- 3-channel digital online monitoring system with built-in pump
- LED-Display for triple ISO codes
- According to ISO 4406:1999 4µm(c), 6µm(c), 14µm(c) based on ISO 11171:1999 calibration and
- According to ISO 4406:1987 (2µm), 5µm, 15µm based on ISO 4402 calibration
- Pressureless sampling as well as pressurized sampling from 7 bar up to 420 bar (6000 psi)
- Flowrate: 25ml/min
- Pressurized sampling up to 350 cSt
- Minimess M16x2 and standard connectors (DIN ISO 2353) or user specific
- Operates on 90 - 230 V AC (50/60 Hz), 12 - 30 V DC
- Optional 4-20mA output
- Optional Alarm-Relay output
|
|
|
|
|
|
Icount Particle Detector
The Icount Particle Detector from Parker represents the most up-to-date technology in solid particle detection. The design dynamics, attention to detail, and small size of the permanently mounted, on-line particle detector brings a truly innovative product to all industry. The laser based, leading-edge technology is a cost effective market solution to fluid management and contamination control.
Features and benefits of the Icount PD include:
• Independent monitoring of system contamination trends.
• Early warning LED or digital display indicators for Low, Medium and High contamination levels.
• Moisture % RH LED indicator (optional).
• Cost effective solution in prolonging fluid life and reducing machine downtime.
• Visual indicators with power and alarm output warnings.
• Continuous performance for dependable analysis.
• Hydraulic, phosphate ester & fuel fluid compatible construction.
• Self diagnostic software.
• Fully PC/PLC integration technology such as: RS232 and 0-5 Volt, 4-20mA.
|
|
|
|
|
|
Icount PD
A new generation of detectors of particles on which industry can "count"
Technical description:
Technology of luminous screening per laser diode recognized by industry
Approved calibration, methods on line
Indicators LED for levels detected ISO & NAS
Technology entirely PC compatible /PLC
Simple connection by catches of M16 test or with an interface by sensors STI on line.
Advantages:
The most modern technology in the field of the analysis of the contamination by solid particles
Trace program of preventive maintenance
Analyzes on site combined with the laser technology
Simple communication protocols for the configuration of use and exploitation
Ecological nylon material reinforced with glass fiber
Accreditation IP66
Economic solution.
Applications:
Mobile sylviculture
Industrial facilities, paper Paper & pulp - Steel-works - energy Conversion
Transformation of alternative energy - Systems of transmission for wind mills
Installations of military support on the ground - testing grounds & quality control.
|
|
|
|
|
|
Leakwise Oil on Water Monitor
Leakwise Oil on Water MonitorLeakwise Oil-on-Water Monitoring and Detection Systems from GE Analytical Instruments provide early, reliable, low maintenance warning of hydrocarbon leaks and spills 24/7 without false alarms. A Leakwise system consists of a wire or wireless signal processor and one of more sensors, depending on the application.
Leakwise oil detection sensors use high frequency electromagnetic energy absorption floating sensors, which enable reliable monitoring of hydrocarbon on water regardless of dirt or oil coating of the sensor or change in water level or water salinity. Advantages include:
%u2022 Provides reliable coverage 24/7 with no false alarms
%u2022 Operates virtually maintenance free for years
%u2022 Detects oil layer thickness (as little as 0.3 mm)
%u2022 Offers an affordable solution for oil leak detection
Applications include oil leak monitoring at refineries, petrochemical plants, pipelines, gas stations, power plants, underground transmission, remote substations, transformer switchyards, marine ports, airports, steel and aluminum manufacturing plants, offshore rigs, groundwater and stormwater runoff, wastewater treatment plants and more.
Leakwise is also an ideal tool for strengthening Spill Prevention Control and Countermeasure (SPCC) plans, as required by the USEPA.
|
|
|
|
|
|
Model 6600 Oil-in-Water Analyzer System
Teledyne's Model 660/661 was the industry standard in oil-in-water analysis for 30 years. The microprocessor based 6600 / 6610 improves upon our proven analog circuitry and the sample handling system. The new, compact modern design incorporates many new features at a significantly reduced cost. Critical features include:
Folded optical system optimized for excellent signal-to-noise ratio and stability
Increased reliability by eliminating many moving parts
New sonicator homogenizes oil (in-line) in water instantly (less than one second)
Improved auto-zero filter system prepares zero fluid for calibration and zeroing without long sparging cycle
Specially developed software with auto calibration features
Automatic self-cleaning sample cell suitable for high pressure and temperature
Manual calibrations done easily with collected zero fluid from sample system using the gravity fed reservoir
Manual or automatic span sensitivity easily checked with internal span flag once field calibrated
Faster response time
Modular design configured to meet specific application requirements
|
|
|
Oil content analyzer for water or soil applications. This 5 minute test provides an accurate analysis using Horiba's S-316 extraction solvent.
|
|
| ... products without technical information |
| |
|
|