The CT224 consists of a 12-Channel Temperature Monitor and MincoSoft™ CT224 Software. It is the next generation in temperature monitoring equipment from Minco designed to meet the needs of electric machinery protection. The 12-channel scanning capability, standard RS485/RS232 interface and Windows-compatible software utility for system configuration and data logging provide overtemperature and undertemperature protection and critical feedback to safeguard expensive machinery.
|
|
|
|
|
|
Multi-funcitonal Thermocouple Thermometer ( DTM-3105 )
Thermocouple Thermometer Model DTM-3105
FUNCTION:
ON/OFF, HOLD/TEST, °F/°C, MIN/MAX ( °F/°C) MEMORY RECALLING
* Carrying Case and 4 TC probes Included
PROBE MODEL NO.:
1. DTM-3105-TPK4 Surface probe (230 mm)
2. DTM-3105-TPK5 Air probe (235 mm)
3. DTM-3105-TPK03R Round head immersion probe (130mm)
4. DTM-3105-TPK03S Pin point head immersion probe(125 mm)
FEATURES:
Rubber coated product case
High degree of accuracy
Extra EVA box for easy and protective storage
Four probes included
Comprehensive and variety use for different object (e.g. surface, semi-solid, air)
Large LCD display
MEASUREMENT RANGE
-100°C ~ +300°C or -148°F ~ + 572°F
RESOLUTION:
0.1° for -199.9° ~ +300.0°
ACCURACY:
± 2°C from -200°C ~ -50°C (or 4°F from -328°F ~ -58°F)
± 1°C from -49°C ~ +300°C (or 1.8°F from -56.2°F ~ +572°F)
Accuracy is specified for operating temperatures over the range of 18°C to 28°C (64°F to 82°F). The basic accuracy specification does not include the error of the thermocouple probe.
|
|
Limit value monitoring devices
SG-mc Digital
Limit Indicator
35 mm DIN - rail mounting
* Universal sensor input
* (Pt 100,TC, 0 / 4...20mA, 0...10VDC)
* Alarmcontact free programmable with latch function or without latch function.
* Latch-reset by mini-switch or by power on/off
* Easy handling
|
|
|
|
|
|
The LumaSense Accufiber®TR solution provides temperature monitoring with automatic emissivity correction. Emissivity changes are due to changing material properties during certain types of material deposition or processing. For specular (smooth) surfaces, the deposition surface’s emissivity can be calculated from its reflectance. By constantly measuring this reflectance, the AccufiberTR instrument can automatically perform the emissivity correction in-situ and calculate the surface’s true temperature.
AccufiberTR seamlessly integrates ultra precise reflectance measurements with LumaSense’s class leading, lowest signal-to-noise ratio radiation detectors. If the n and k values are known for the materials, then the amplitude and periodicity of the thin film reflectance (often referred to as “fringes”) at specific wavelengths can be used to calculate film thickness. For thin films, it is critical to use both the highest quality measurement systems and shorter wavelengths to offer “resolution” into the film’s fringes to monitor film thickness.
|
|
Turbine Sentry - System Overview
An overview of the complete system and how this system is of benefit to gas turbine operators.
A typical system comprises three parts:
Blade Sentry - Measurement Pyrometer
The non-contact thermometer is mounted through the gas turbine casing and measures the temperatures of individual rotor blades.
Rotor Sentry - Data Acquisition System
The DAS logs individual blade temperature readings taken by the measurement pyrometers, samples and processes the data for use by the data analysis software, Data Sentry.
Data Sentry - Data Analysis Software
This powerful pc-based software utility has all the tools and functions necessary to obtain a complete picture of how efficiently the gas turbine is running, as well as identifying potential problems at an early stage.
|
|
| ... products without technical information |
| |
The powerful indicator N1500 offers among its universal input and the 2 relay outputs for the monitoring of the threshold values many other functions. The Min.- and Max.-values can be prompted with just a keystroke. Also there is a Hold and a Peak-Hold Function whose readouts can be deleted using either the function key or the digital input. The high tact frequency of 15 measurements/second (5 measurements/second when using linear input, thermocouples or Pt100) allows the N1500 indicator to monitor fast processes. It offers also the possibility to linearise the measurement signal when using non-linear input signals (mV, V, mA).
Features:
- Universal input
- Linearization of mV, V, mA signals
- 2 Relay outputs
- 6 Alarm features
- Voltage output 24 VDC for external 2-wire transmitter
- Memory for MAX and MIN values, hold and peak features
See more information in our shop:
***www.temperature-shop.de***
|
|
Enhanced indicator
Double input Indicator - Transmitter with four addressable alarms
1/8 DIN 96x48
Universal input for temperature sensors, mA, mV, Volt, IR, custom
High level second input 0/4...20 mA, 0/1...5, 0...10 V
3 digital inputs
3 SPST relays NO, 1 SPDT relay
0/4...20 mA retransmission output
4 addressable alarms with delay, latching and blocking functions
ISA sequence on alarms
Display of MIN, MAX value
Hold and temporized hold to display peaks
Dedicated alarm acknowledge key
5 digits 2 colors display with different combinations
RS 485 serial communications
Power supply 100...240 Vac, 24 Vac,dc
Transmitter power supply
IP65 front panel protection
|
|
|
|
|
|
MOLTEN METAL TEMPERATURE INDICATOR
PRODUCT DESCRIPTION:
Libratherm offers microcontroller based Molten Metal Temperature Indicator model LMI-2010, which is designed to accurately measure temperature of the molten metals, both ferrous and non ferrous. The measurement of this temperature is a critical process, since the expendable thermocouple is dipped for merely 3 to 4 seconds and then withdrawn. In this short measurement time, the operator is guided through the measurement cycle by audio/visual alarms for thermocouple continuity, measurement in progress and measurement over. Any error in measurement or thermocouple open condition is also immediately detected by activating the audio/visual alarm.
User can select the desired type of thermocouple (either K, R, S, or B type, (depending upon the measuring range from 1200 to 1800oC), and can also set other parameters using front panel key board. During measurement, the indicator ignores the slag temperature and the Average or Plateau reading is determined using the advanced algorithm and the same is latched and displayed on the bright 7 segment 2” LED display. This reading can also be displayed on 4” remote display LRU-2010 and can be logged on to a computer using serial RS485 MODBUS RTU protocol for recording and analysis purpose. Libratherm offers supporting window based software.
|
|
Various sizes displays with or without alarm functions.
Different mounting types f.ex wall or panel mounting.
|
|
- Big keys for use with gloves
- Programmable characteristic curve end points (up to 24 control points)
MIN/MAX value detection,
- Display-Hold
- Auxiliary power output for measuring transducer/sensor
- Optocoupler or relay outputs
- Programmable limit values
- Optional: with serial interface
|
|
|
The Tecal Accu-Temp is a good choice for use as a laboratory grade reference thermometer. It's available in a single or dual channel model, along with direct temperature readout in degrees F, C and ohms. Combine the Tecal Accu-Temp with one of our secondary standard PRT's for a high accuracy temperature measurement system. Don't rely on battery operated, low accuracy hand-held model PRT indicators for your critical temperature measurements.
|
|
S1305
Format: 96x96 mm (1/4 DIN)
Installation depth: 122 mm
The universal monitoring instrument
* Instrument with 3 limit contacts
* Universal Input (Pt 100, TC, 0 / 4...20mA, 0...10Vdc)
* Easy handling
|
|
| ... products without technical information |
| |
|
|
|
|
|
The J5 provides measurement of melt pressure and other process variables. The J5 features a large 5 digit display that can operate in either green or red or change color in case of alarm. The J5 is configurable from the front, or from a PC with a software tool. The main input is for Strain Gauge or linear DC voltage/current with square root extraction or with a 16 segment linearizer. The second input with DC voltage or current is suited to temperature indication and signal conditioning (min, max, average, ratio, etc.) when combined with the main input. The J5 has 3 digital inputs independently configurable for alarms, display and calibration handling. Up to four alarms with ISA-A acknowledge are available as well as a retransmission output and Modbus RS485 comms. The J5 has three levels of password protection and the front panel is IP65. The strain gauge bridge of the melt pressure or load cell transducer can be powered by an internally regulated 5 or 10Vdc. The reliability of the strain gauge is monitored continuously. A front panel calibration routine is provided to automatically remove zero and span offsets. The automatic calibration can also be activated by using front keys, one of the three digital inputs, or over serial comms. Tare function for load cells is provided.
|
|
The JOFRA range of IPI Industrial Pressure Indicators is ATEX and CSA certified for use in potentially explosive environments in the field or in calibration laboratories. ATEX is the primary intrinsically safe standard in the European Union, while CSA refers to relevant Canadian and USA standards.
Accurate to ± 0.05% FS, the IPI can be used as a calibration reference or in applications where high accuracy pressure measurement is required from safety valve checks to system pressure verification. This Ex certification will allow the IPI to be used in any industry where there is a risk of flammable gases. These include oil refineries, off-shore platforms, chemical plants, gas production plants, oil and gas shipping, pharmaceuticals and in whisky distilleries.
|
|
HVAC measurement device PascalMaxx for monitoring & control
Differential pressure instrument with membrane measurement technology for monitoring and control of differential pressures and air flows in HVAC applications. Suitable for rooms and ducts.
By the integrated switch the pressure conditions can be monitored and an alarm set in case of need. The also integrated analogue outputs (V and mA) can be used for a system control. The automatic Zero-Point calibration assures an accurate and reproducible measurement at any time and avoids any influence of the mounting position on the measurement results.
|
|
Digital Pressure Controller/Calibrator - Model 7250
The Model 7250 Digital Pressure calibrator is available in a variety of pressure ranges from 0-5 psi to 0-3000 psi, and is an economical alternative to the Model 7250xi and 7250i. The Model 7250 provides 0.003% of full scale precision and can control to the set point in 15 seconds with no overshoot. When a higher level of performance is required, please refer to the 7250i and 7250xi Digital Pressure Controllers.
|
|
Pressure Indicators
The Vista-Gage is a unique piston-type pressure indicator, specifically designed to withstand machine vibration, shock, pulsation, pressure surges and other rigorous conditions that create problems for conventional pressure gauges, with fragile bourdon tube mechanisms. Available in Vista-Gage for High-pressure, Lo-pressure and Vacuum indicators, Vista-Cator for GO/NO-GO indicators, and Vista-Monitor for Accumulators.
|
|
|
The series A2 digital differential pressure gage is a patent pending microprocessor based digital pressure gauge for positive, negative, and differential measurement designed to be a direct replacement for mechanical gauges. The Series A2 differential pressure gauges utilize an extremely stable piezoresistive sensing technology to give a standard full scale accuracy of 1%. For applications requiring better accuracy, the A2 is also available with 0.5% accuracy. The A2 pressure gauge also has an optional 4-20 mA output for applications requiring an output signal. The A2 features a bright ½" LED display and process arch, which gives the gauge improved readability and precision. The A2 digital differential pressure gauges also feature 5 user selectable engineering units including in. w.c., mm w.c., cm w.c., kPa, and Pa. The Series A2 offers an improved look, and performance compare to mechanical gauges.
|
|
|
|
|
|
ServiceJunior without yarn.
Little genius of the diagnosis
Description:
- Transmission without yarn of the data.
- Possibility of data acquisition on the long term.
- Digital display with lighting.
- Conceived for remote control.
- Kit containing the JuniorWin software for PC.
- Function selected of peak (posting with bars and function actuated needle).
- Measurement of the points of pressure at rate of 10 ms reading (function max. min/).
- Range 50 m minimum.
- Whole Posting of the scale.
- Simplicity of handling by 4 keys.
- Integrated Battery: lifespan 1.500 hours.
- Index of protector IP54.
- Beach of pressure: -1... 16 bar/0... 100 bar/0... 400 bar/0... 600 bar.
Advantages:
- "Intelligent" Management of the memory.
- Is based on technology without wire, no connection by cable towards the PC is not necessary.
- A faster transfer of the data Allows the PC.
- Direct and simple Connection of ServiceJunior on the hydraulic system.
- No other portable apparatus nor another sensor and cable are necessary.
- Simple Use with lower costs for better results.
- Robust Enclosure not dirtying.
Applications:
- Machine tools
- Mobile Machines
|
|
|
|