Transducer and switching modules for temperature, humidity and pressure, explosion proof
Elektrical, explosion proof trandsucer, series ExCon-A, Red-Con-A, ExCon-D, RedCon-D and EXL-IMU-1 as well as switching modules series EXL-IRU-1, to connect modulating or binary temperature, humidity and pressure sensors, in acc. with ATEX 94/9/EG for use in hazardous areas zone 1, 2, 21 and 22 (in acc. to sensor type), for all kind of gas, mixtures, vapours and dust. 24 VAC/DC supply, adjustable on site, integral display for programming and for actual value indication.
series ExCon-A for modulating, analogue sensors (type ExSens) and ExCon-D for modulating, digital sensors (type ExPro), for use in hazardous areas zone 1, 2, 21 and 22. series RedCon-A modulating, analogue sensors (type ExSens) and RedCon-D for modulating, digital sensors (type ExPro), for use in hazardous areas zone 2 and 22.
series EXL-IMU-1 for modulating, analogue sensors (type ExSens) for use of sensors in zone 1, 2, 21 and 22, the module must be installed in the safe are and is prepared for DIN rail mounting.
series EXL-IRU-1 for binary, analogue sensors (type ExSens) for use of sensors in zone 1, 2, 21 and 22, the module must be installed in the safe are and is prepared for DIN rail mounting. |
|
New! The Vaisala Combined Pressure, Humidity and Temperature Transmitter PTU300
Vaisala introduces a new generation barometric pressure, relative humidity and temperature transmitter series, the Vaisala Combined Pressure, Humidity and Temperature Transmitter PTU300. The PTU300 features fully digital measuring electronics for all three parameters, several small RH&T sensor heads for different applications, and calculated humidity variables. The new backlit display shows three-hour graphical trends and up to one year of historical data. The recorded measurement data can be viewed on the display or transferred to a PC. Seven languages options are also available.
The PTU has four different probe options: PTU301 for laboratories, PTU303 for outdoor use, the warmed PTU307 probe for demanding meteorology, and the PTU30T for pressure and temperature measurement only.
The Vaisala BAROCAP® sensor is used for pressure measurement and the Vaisala HUMICAP® sensor measures humidity. Both sensors are known for their high accuracy and long-term stability. The temperature sensor is a platinum RTD sensor.
Applications include environmental monitoring in calibration laboratories, GPS meteorology and weather stations.
|
|
Measuring range : from 0/+10 Pa to -10 000/+10 000 Pa
Configurable intermediary and central zero ranges
Air velocity and airflow functions
Interchangeable measuring sensor (SPI technology)
Simultaneous display of 1 to 4 parameters
External transmitter unputs (KIMO class 200 and 300) and thermocouple K
2 output 4-20 mA or 0-10 V (4 wires), RS 232, 2 RCR relays 6A/230 Vac
2 visual (dual color LED) and audible (buzzer) alarms
Software, keypad or remote control configuration
MODBUS network RS 485 system (optional)
ABS or ALU IP 65 housing, with or without backlit gaphic display
Mounting with the 1/4 turn system with wall-mount plate
CP301 : -100/+100 Pa
CP302 : -500/+500 Pa
CP303 : -1000/+1000 mbar
CP304 : -10 000/+10 000 mbar
• Barbed fittings Ø 5,2 mm
• Unit of measurement : Pa, mmH2O, mbar, inWG, mmHG
• Power supply : 24 Vac /Vdc, 115 Vac or 230 Vac
• Outputs : 2 x 4-20 mA or 2 x 0-10 V
• Functions : pressure, air velocity, airflow with Pitot tubes, Debimo and other coefficients, integration of measure, self-calibration, measuring correction factor, temperature compensation : manual or automatic (thermocouple K input). |
|
Transducer and switching modules for temperature, humidity and pressure, explosion proof
Elektrical, explosion proof trandsucer, series ExCon-A, Red-Con-A, ExCon-D, RedCon-D and EXL-IMU-1 as well as switching modules series EXL-IRU-1, to connect modulating or binary temperature, humidity and pressure sensors, in acc. with ATEX 94/9/EG for use in hazardous areas zone 1, 2, 21 and 22 (in acc. to sensor type), for all kind of gas, mixtures, vapours and dust. 24 VAC/DC supply, adjustable on site, integral display for programming and for actual value indication.
series ExCon-A for modulating, analogue sensors (type ExSens) and ExCon-D for modulating, digital sensors (type ExPro), for use in hazardous areas zone 1, 2, 21 and 22. series RedCon-A modulating, analogue sensors (type ExSens) and RedCon-D for modulating, digital sensors (type ExPro), for use in hazardous areas zone 2 and 22.
series EXL-IMU-1 for modulating, analogue sensors (type ExSens) for use of sensors in zone 1, 2, 21 and 22, the module must be installed in the safe are and is prepared for DIN rail mounting.
series EXL-IRU-1 for binary, analogue sensors (type ExSens) for use of sensors in zone 1, 2, 21 and 22, the module must be installed in the safe are and is prepared for DIN rail mounting. |
|
New! The Vaisala Combined Pressure, Humidity and Temperature Transmitter PTU300
Vaisala introduces a new generation barometric pressure, relative humidity and temperature transmitter series, the Vaisala Combined Pressure, Humidity and Temperature Transmitter PTU300. The PTU300 features fully digital measuring electronics for all three parameters, several small RH&T sensor heads for different applications, and calculated humidity variables. The new backlit display shows three-hour graphical trends and up to one year of historical data. The recorded measurement data can be viewed on the display or transferred to a PC. Seven languages options are also available.
The PTU has four different probe options: PTU301 for laboratories, PTU303 for outdoor use, the warmed PTU307 probe for demanding meteorology, and the PTU30T for pressure and temperature measurement only.
The Vaisala BAROCAP® sensor is used for pressure measurement and the Vaisala HUMICAP® sensor measures humidity. Both sensors are known for their high accuracy and long-term stability. The temperature sensor is a platinum RTD sensor.
Applications include environmental monitoring in calibration laboratories, GPS meteorology and weather stations.
|
|
|
|