Fast and accurate readings from bearings, blocks, and other solids. Minco’s spring-loaded holder ensures solid contact in drilled holes and has a built-in oil seal. The sensing probe features a copper alloy tip for quick response to temperature changes.
- Tip-sensitive RTD probe for use to 260°C (500°F)
- Spring-loaded holder with fluid seal
- Cast iron, stainless steel, or aluminum connection head
|
|
Since 1984 B&B Thermo-Technik develop and manufacture successfully temperature probes.
New ideas were always a reason why B&B is one step further than its competitors. Our customers are the focus of our thinking and acting. For them we investigate, analize and realize almost everything in the temperature measurement.
Just send us your inquiry and we will supply you with a detailed offer and the solution for your measuring problem.
You will find our range of standard sensors in our Online-Shop:
www.temperature-shop.eu
There you will also get more information about our range of temperature measuring technics:
- Temperature / Humidity Sensors
- Thermocouple Connectors
- Digital Thermomters
- Infrared Thermomters
- Stationary Pyrometers
- Controllers
- Indicators
- Data Loggers
- Hygrometers
- Transmitters
|
|
|
The Model 2A Thermocouple Sensor tube consists of a tube containing a filament heated by the passage of a constant current. A thermocouple is welded to the center of this heated element thereby providing a means of directly measuring the element temperature in terms of voltage output. For any constant value of current through the filament, the temperature of the filament increases as the pressure in the tube is reduced. The thermocouple voltage is directly proportional to the increased temperature of the filament, and thus generates an increase in voltage. Sensitive circuitry includes the thermocouple output directly in microns. The standard sensor tube has nickel-plated, forged-brass housing which makes it capable of withstanding 150 psi overpressure. All thermocouple elements are preoxidized under controlled conditions to provide interchangeability of tubes without recalibration. This process also provides high stability and minimizes the effect of contamination. Stainless steel versions are available.
|
|
Examples:
-Screw-in resistance thermometers with connecting cable (90.2005)
for temperatures from -50 to +400°C
as single or twin resistance thermometer
in 2-wire, 3-wire or 4-wire circuit
connecting cable in PVC, silicone, Teflon or with metal braiding
-JUMO PROCESStemp Resistance thermometers for process technology with ATEX approval in stainless steel with 2-wire transmitter (HART/Ex) for temperatures from -200 to 600°C (90.2820):
for temperatures from -200 to 600°C
with protection tubes in stainless steel, titanium, tantalum, Inconel and Hastelloy
available with 2-wire transmitter (4 - 20mA / HART®) in Ex version
Ex II 1/2 GD EEx ia II C T1 - T6 IP 6x T80 - T400°C
Ex II 1/2 GD EEx d II C T1 - T6 IP 6x T80 - T400°C
with replaceable measuring insert
|
|
Temperature sensor
- resistance and thermoelectric temperature sensors
- for various branch of industry ( cement industry, energy industry, food industry)
- measuring temparature: from -200.. to 1600C
- Atex certificate
Temperature transmitters
- Head-mounted and rail-mounted temperature transmitters
- output signal: 4-20mA or Hart protocol (model LI-24)
- Atex certificate.
|
|
CHARACTERISTICS
General use sensor. Working temperature range -200ºC to
+850ºC.
Connexion to the process can be adjustable through compression
fitting, free insertion without coupling, or thermowell.
Removable measuring unit, RUM model.
Ceramic support, optional transmitter 4...20 mA.
Complying DIN 43760 standard.
APPLICATIONS
- Industries
- Laboratories
- Food sector
- Sanitary sector
SPECIFICATIONS
Process connexion BSP, NPT, METRIC, ETC...
Sensor tube diameter 3, 4, 6, 8... 15mm
Sensing element Pt100
Connexions 2, 3 and 4 wires
Accuracy CLASS A or B (option 1/3, 1/5, 1/6, 1/10DIN)
Measurement range -200ºC to +600ºC (option 850ºC)
|
|
The Omnigrad range of Temperature Products from Endress Hauser meets the high standards required by the process industry.
Omnigrad provides Endress Hauser quality in design, documentation, logistics and service in Temperature Sensors.
A Resistance Temperature Detector (RTD) is a temperature responsive device based on a predictable resistance change in the sensing element.
The EN 60751 standard specifies requirements for industrial Platinum resistance sensors and covers the Pt 100 thermometers.
The Pt 100 sensing element has a resistance of 100 %u03A9 at 0°C.
According to EN standard and most common industrial applications, the Pt 100 type sensors are used for temperature measurement and control in the range from -50°C to 400°C or -200°C to 600°C.
RTDs offer three main advantages:
high accuracy
excellent long-term stability
high signal output level which allows transmission over long distances without ancillary equipment.
Basic construction of Platinum resistance elements cannot be used directly in contact with process environments, hence the complete thermometers are built as assemblies which can withstand light, medium and heavy duty industrial conditions.
In general, the sensor assembly includes three components:
the resistance thermometer inset
the protecting tube (thermowell)
the terminal housing.
|
|
Roessel resistance thermometers for particular applications:
- Grooved resistance thermometers
- Temperature sensors for heat quantity meters, government-certified
- Resistance thermometers for ocean vessel shipyards, GL-certified
- Resistance thermometers for the plastics industry
|
|
Applications:
- Machinery, plant and tank construction
- Energy and power plant technology
- Chemical industry
- Food and beverage industry
- Sanitary, heating and air-conditioning technology
Special Features:
- Application ranges from -200 °C to +600 °C
- Suitable to assemble with all standard thermowell designs
- Spring loaded measuring insert (exchangeable)
- Explosion-protected versions Ex-i, Ex-n and NAMUR NE24
Description:
Resistance thermometers in this series can be combined with a large number of thermowell designs. Operation without thermowell is only recommended for specific applications. An extensive range of sensors, connection heads, insertion lengths, neck lengths, thermowell connections etc. are available for these thermometers, so that they are suitable for all thermowell dimensions and applications. Intrinsically safe designs are available for applications in hazardous areas.
|
|
| ... products without technical information |
| |
|
The ground resistance of substations can be measured with two auxiliary electrodes which are put into the ground. To avoid influences from the mains current and its harmonics, this measurement should preferably be carried out with 128 Hz.The high output power of the CPC 100 ensures a high ratio of the signal level to the noise level. Thanks to the signal processor technology, the measuring procedure is very selective and disturbances by ground currents are reduced to a minimum.
|
|
Earth Testing covers the testing of earth electrodes and the measurement of soil resistivity. The instrument requirements depend on the range of applications.
|
|
FEATURES:
1. DIM 571 is a LCD Indicated instruments for insulation (M Ohm), Continuity (OHM) and AC Voltage
2. Three Insulation test voltage (DCV): 250V, 500V, 1,000V.
3. Large LCD display(68 x 34mm)
4. Test Insulation at rated voltate into 1 1mA load
5. 200mA short circuit continuity current.
6. Timer for test functions (3 ~ 5 minutes)
7. Data Hold function
8. Auto power off function
9. Automatic circuit dischage
10. Fuse proection
11. EN61010 CAT III 600V
12. BS 16" Edition
|
|
Description:
Reads ground resistance down to 0.10Ohm.
- Fully autoranging with data hold to capture readings.
- Convenient alarm and 99-point memory functions.
- Measures up to 30A RMS ground or leakage current.
- Measures currents down to 1mA.
- Accessories included: (1) 9V battery, molded carrying case, test resistance loop.
|
|
METRISO 5000A: analog high-voltage insulation measuring instrument with 4 measuring voltages: 100, 250, 500
and 1000 V (per EN 61 557 part 2) and 1500, 2000, 2500 and 5000 V
METRISO 5000AK: The battery powered METRISO 5000 A is converted into the muscle powered
METRISO 5000AK by replacing the battery module with a crank generator.
- Extensive measuring range: 10 kOhm... 1 TOhm
- Measuring range: 100 kOhm... 100 MOhm (1000 V)
- Measuring voltages: 100 V, 250 V, 500 V, 1000 V, 1500 V, 2000 V, 2500 V, 5000 V
- Measurements to 1000 V per DIN VDE 0413
- Voltage measurement to 2000 V ,
- Concise logarithmic display
- Guard terminal for the elimination of surface current
|
|
| ... products without technical information |
| |
|
|