Since 1984 B&B Thermo-Technik develop and manufacture successfully temperature probes.
New ideas were always a reason why B&B is one step further than its competitors. Our customers are the focus of our thinking and acting. For them we investigate, analize and realize almost everything in the temperature measurement.
Just send us your inquiry and we will supply you with a detailed offer and the solution for your measuring problem.
You will find our range of standard sensors in our Online-Shop:
www.temperature-shop.eu
There you will also get more information about our range of temperature measuring technics:
- Temperature / Humidity Sensors
- Thermocouple Connectors
- Digital Thermomters
- Infrared Thermomters
- Stationary Pyrometers
- Controllers
- Indicators
- Data Loggers
- Hygrometers
- Transmitters
|
|
Examples:
-Screw-in resistance thermometers with connecting cable (90.2005)
for temperatures from -50 to +400°C
as single or twin resistance thermometer
in 2-wire, 3-wire or 4-wire circuit
connecting cable in PVC, silicone, Teflon or with metal braiding
-JUMO PROCESStemp Resistance thermometers for process technology with ATEX approval in stainless steel with 2-wire transmitter (HART/Ex) for temperatures from -200 to 600°C (90.2820):
for temperatures from -200 to 600°C
with protection tubes in stainless steel, titanium, tantalum, Inconel and Hastelloy
available with 2-wire transmitter (4 - 20mA / HART®) in Ex version
Ex II 1/2 GD EEx ia II C T1 - T6 IP 6x T80 - T400°C
Ex II 1/2 GD EEx d II C T1 - T6 IP 6x T80 - T400°C
with replaceable measuring insert
|
|
Applications:
- Machinery, plant and tank construction
- Energy and power plant technology
- Chemical industry
- Food and beverage industry
- Sanitary, heating and air-conditioning technology
Special Features:
- Application ranges from -200 °C to +600 °C
- Suitable to assemble with all standard thermowell designs
- Spring loaded measuring insert (exchangeable)
- Explosion-protected versions Ex-i, Ex-n and NAMUR NE24
Description:
Resistance thermometers in this series can be combined with a large number of thermowell designs. Operation without thermowell is only recommended for specific applications. An extensive range of sensors, connection heads, insertion lengths, neck lengths, thermowell connections etc. are available for these thermometers, so that they are suitable for all thermowell dimensions and applications. Intrinsically safe designs are available for applications in hazardous areas.
|
|
Fast and accurate readings from bearings, blocks, and other solids. Minco’s spring-loaded holder ensures solid contact in drilled holes and has a built-in oil seal. The sensing probe features a copper alloy tip for quick response to temperature changes.
- Tip-sensitive RTD probe for use to 260°C (500°F)
- Spring-loaded holder with fluid seal
- Cast iron, stainless steel, or aluminum connection head
|
|
ET50x series push-in resistance thermoprobes with terminal head are intended for measuring temperatures in liquids and gases. Applications include HVAC and refrigeration, heating installations,ovens, furnaces and plant engineering, as well as industrial automation.
- For measuring temperatures from -50 to +500 ° C
- Pt100, Pt500, Pt1000, PTC1000 or NTC resistance sensor
- Double RTD sensing element option
- Variety of DIN B type and miniature terminal heads
- AISI 316 s/s process connection, options of adjustable fittings
- Head-mountable transmitters available — to provide
0-10 V / 4-20 mA or RS485 Modbus RTU communication
|
|
|
|
|
|
Contact Temperature Sensors
- Platinum Pt100, Pt1000, Nickel, NTC, KTY Sensors
- PVC, Silicone, PTFE, Stainless steel cable or in a case
- impact-resistant plastics case protection class IP65
Outdoor Temperature Sensors
- Platinum Pt100, Pt1000, Nickel, NTC, KTY Sensors
- optional case with external probe tube for fast detection
- impact-resistant plastics case protection class IP65
Screw-In Temperature Sensors
- Platinum Pt100, Pt1000, Nickel, NTC, KTY Sensors
- impact-resistant plastics case protection class IP65 optional with display, high-quality aluminium connecting head form J / form B
- brass or stainless steel immersion sleeve
Hand Infeed Sensors
- PTFE or plastic hand grip
- PVC, silicone or PTFE cable
- water-vapour-proof casted
Cable Temperature Sensors
- Platinum Pt100, Pt1000, Nickel, NTC, KTY Sensors
- PVC, Silicone, PTFE, Stainless steel cable with different lengths
- moisture sealed rolled
Duct Temperature Sensors
- Platinum Pt100, Pt1000, Nickel, NTC, KTY Sensors
- Impact resistant plastics case protection class IP65
- high-quality aluminium connecting head form J, form B
Surface Temperature Sensors
- Platinum Pt100, Pt1000, Nickel, NTC, KTY Sensors
- PVC, Silicone, PTFE, Stainless steel cable with different lengths
- self-adhesive, screw-on type, magnetic
Room Temperature Sensors
- Platinum Pt100, Pt1000, Nickel, PTC, NTC, KTY Sensors
- modern room housing design with air slots
- alternatively with rotary switch, potentiometer, LEDs, level switch etc.
Radiation Temperature Sensors
- Platinum Pt100, Pt1000, Nickel, PTC, NTC, KTY sensors
- measurement range -30...+75°C
- windchill factor
|
|
Roessel resistance thermometers for particular applications:
- Grooved resistance thermometers
- Temperature sensors for heat quantity meters, government-certified
- Resistance thermometers for ocean vessel shipyards, GL-certified
- Resistance thermometers for the plastics industry
|
|
Application Notes:
Good as test probe
Used with or without thermowell
Isothermal head enclosure for accuracy
Protected terminations
DIN standard lengths available
Special Options:
Duplex
Higher accuracy sensors A, 1/3,1/5,1/10 DIN
Pt 50, Pt 500, Pt 1000 and Pt 2000, Cu or Ni element
2 or 4 wires
RT can be replaced with a thermistor
Various IP rated heads available
Transmitter available in head
Tagging
Compression fitting
RT can be replaced with a thermistor
|
|
- Compact
- Bendible
- Vibration resistant
- Fast response
- Fixed cable, plug as also conncetion head
Applications
Chemical engineering
Petro Chemistry
Food and Beverage
Thermprocess
Boiler
Plast and Fibre
Pulp and paper
Research and Development
Main attributes
3- and 4-wirw configuration
Class A and B to DIN EN 60 751
Sheath made of 1.4541 (max. 600 °C)
Response time depending from dimensions
T50 from 1,5 s (3 mm diam) onwards
|
|
Type
Pt 100, 200, 500, 1000,
copper 50,53. etc
Element size (MI)
Wire wound ceramic encapsulated
Wire wound Glass encapsulated
Thin film ceramic encapsulated
Connection
2, 3, 4 wire
Accuracy
Class A, B 1/2, 1/3, 1/5, 1/10 DIN
Protection Sheath
SS 304, SS 316, SS 310, Inconel,
Hastalloy, Monel Etc
|
|
Temperature sensor
- resistance and thermoelectric temperature sensors
- for various branch of industry ( cement industry, energy industry, food industry)
- measuring temparature: from -200.. to 1600C
- Atex certificate
Temperature transmitters
- Head-mounted and rail-mounted temperature transmitters
- output signal: 4-20mA or Hart protocol (model LI-24)
- Atex certificate.
|
|
|
|
|
|
|
The Model 2A Thermocouple Sensor tube consists of a tube containing a filament heated by the passage of a constant current. A thermocouple is welded to the center of this heated element thereby providing a means of directly measuring the element temperature in terms of voltage output. For any constant value of current through the filament, the temperature of the filament increases as the pressure in the tube is reduced. The thermocouple voltage is directly proportional to the increased temperature of the filament, and thus generates an increase in voltage. Sensitive circuitry includes the thermocouple output directly in microns. The standard sensor tube has nickel-plated, forged-brass housing which makes it capable of withstanding 150 psi overpressure. All thermocouple elements are preoxidized under controlled conditions to provide interchangeability of tubes without recalibration. This process also provides high stability and minimizes the effect of contamination. Stainless steel versions are available.
|
|
Temperature Probes
The Honeywell range of probes provides reliable temperature detection by conversion of temperature to a resistance value. The probes are compatible with the Honeywell Refrigeration range of temperature controllers and monitors.
The probes are available in 2k (two versions), 3k, 5k, 20k and PT1000 variants, and are all designed to operate in, and accurately detect, temperatures between -40°C and +100°C (-40° F and +212°F).
Probe Range
Black NTC 2k resistance @ 25°C (77°F)
Black* NTC 2k resistance @ 25°C (77°F)
Orange NTC 3k resistance @ 25°C (77°F)
Green NTC 5k resistance @ 25°C (77°F)
Brown NTC 20k resistance @ 25°C (77°F)
Red PTC 1k resistance @ 0°C(32°F)
|
|
|
|
|
|
Type Designation: CRM
Measuring Range: -100 to + 500 ° C
Common Sensor Types: 1 Pt 100 B
Common Sensor Size: 2 x 2.2mm, Thin film
Temperature Coefficient: 0.3850 ohms /° C
Wiring: 3 wire, marked red/red/white
Common Pocket Diameters: Ø 2.0mm to Ø 12.7mm,
Common Insulation: PVC, silicon rubber, PTFE, glass fibre
Common Stranding: 7x0.2
Common Sheaths: 316SS, brass, aluminium
Tail detail: 50mm tails, 10mm tinned
Application Notes:
A very common sensor type
Fast sensor response possible
The enclosure has many possibilities
Highly engineered pockets are possible
Ideal for high volume manufacture and fixing in to original equipment
Very small sizes available
A wide variety of encapsulants for pocket filling
Special Options:
Threaded pocket
Machined high-tolerance metal enclosure
Cable spring relief available
Partial heat transfer paste filling
Duplex
Higher accuracy sensors A, 1/3,1/5,1/10 DIN
Other stranding options
Pt 50, Pt 500, Pt 1000 and Pt 2000, Cu or Ni element
2 or 4 wires
RT can be replaced with a thermistor
IP68 compatible designs
|
|
CA 2001 Resistance Thermometer
These Resistance thermometers are specifically designed for heavy duty temperature sensing applications like ovens, machines and industrial environments where their robust construction ensures a prolonged sensor life. These RTD's are built with a Pt100 detector and available in accordance with IEC class A, B and 1/10B. Optional a two-wire headmounted transmitter can be supplied and also ATEX certification for areas with the risk of an explosion, zone 0, 1, 2, 21 and 22.
|
|
- Sensor Pt 100
- Protection tube made from heat resistant or
- from stainless steelsteel
- Easy transmitter mounting in high doomed connection head
Applications
Dryer, heater,
Recuperators
Boiler, Energy
Chemical engineering
up to 650 °C
Main attributes
Rugged
Good reproducibility
Low ageing
Meets DIN EN 60 751
Class B
different dimensions
2- and 3-wire configuration
|
|
The PT Compact USB is an additional member of the tecsis PT Compact series. The measuring range can be programmed according to the customers demands with especially developed software. The communication between the thermometer and a PC is done via an USB connection. Programming-Kits are not needed.
There are two models of the PT Compact USB. The standard model for temperatures from –50°C up to +200°C and a high temperature model for temperatures up to +600°C, which includes a 100 mm neck tube. The output signal of the PT Compact USB is an analogue 4…20 mA signal.
In order to program the measuring range, it is necessary to remove the measuring insert from the housing. The USB-interface is placed directly on the electronic board of the thermometer.
Precautions have to be taken to avoid ESD-damages, while programming the electronics. You do not have to remove the thermowell of the PT Compact, in order to program the range, thus you do not have to stop your process.
|
|
The sensing element which is generally small - 2 to 5mm diameter - is attached to a stainless steel mineral insulated cable that can be bent.
Tightness between sensing element and cable is achieved by laser welding or brazing. Connection to the readout instrument is made by a cable, a connecting head or a connector.
|
|
| ... products without technical information |
| |
|
|