|
|
Measurement Specialties offers a wide range of standard and customized instrumentation probe assemblies suitable for the instrumentation industry.
Examples include:
- Surface probes
- Air/Gas probes
- Screw-in probes
- Immersion probes
The products are available in a range of resistance/temperature (R/T) curves, electrical tolerances, and mechanical housings.
|
|
Max. Temp: 150°C for Standard Probe
36" Insulated, 26 AWG Stranded Lead Wire
316SS Sheath
1/8, 3/16 and 1/4 " Diameter Sheaths Available
2252 Ohm, 0.2°C Elements Standard, Other 44000 Series Elements Also Available
|
|
NTC temperature probe Part No.: 3025-L00
- NTC temperature probe -50°..+140°C
- With protection tube G 1/2"
- LS=135mm
- D=10mm, p=40bar, 2 terminals, stainless steel V4A
|
|
Features
- Operating temperature range of -20°C to +50°C
- 10 kOhm resistance at 25°C ±10%
- Small size, comformally coated for durability and stability
- Solid nickel wires with Teflon insulation
- Works with all ILX Lightwave Temperature Controllers
The TS-520 is an uncalibrated NTC 10 kOhm leaded thermistor with a baked on phenolic coating for durability and long-term stability. These have solid nickel 30 AWG wires with Teflon insulation to provide insulation when assembled in a heat sink or plate with a lead length of 3 inches (76 mm). They are ideal for measuring the temperature of a laser diode or other component during testing. These devices can be calibrated with accuracies to ±0.05°C over their temperature range using the Steinhart-Hart model
|
|
The precision temperature gauge TEMP12 is an electronic gauge for the temperature measurement.The device is based on a module system. A variety of ranges of application arises from it. These variants are different with respect to the port connected to a computer, the power supply unit, the number of available measuring channels and the design of casing.
The temperature gauge conceptionally was equipped for the highest precision and high long-term stability (at MTBF > 3000 hours). To be able to fulfi ll the high precision standards in the microelectronics production, specially aged NTC sensors will be built-in. The burn-in process which is carried out at approx. 120 degrees Celsius under N2-atmosphere can be at ultra-precision sensors up to 10 years.
|
|
- PT100, PT1000, PTC, NTC
- Liquids and gas application
- Brass or St. Steel probe material
- 1/8" to 3/4" male process connection
- Pmax = 50 bar
- Protection class IP65
|
|
General description:
Multi-purpose temperature probe with 2-1/2" (64 mm)-long stainless steel housing.
Use to measure temperature of air, soil, or water. Add up to four probes to a single Leaf & Soil Moisture/Temperature Station. Includes 15' (4.6 m) direct-burial cable.
Compatible with both original Vantage Pro and Vantage Pro2.
|
|
Temperature
The Hydrolab temperature sensor is a 30k ohm variable resistance thermistor. The temperature sensor is included with every Hydrolab sonde.
Features:
- 316 Stainless Steel, 30k ohm thermistor
- Variable resistor
Benefits:
- Provides critical compensation for Dissolved Oxygen, Conductivity, pH, and nutrient sensors
- Compliant with EPA170.1 and SM2550B
|
|
| ... products without technical information |
| |
Since 1984 B&B Thermo-Technik develop and manufacture successfully temperature probes.
New ideas were always a reason why B&B is one step further than its competitors. Our customers are the focus of our thinking and acting. For them we investigate, analize and realize almost everything in the temperature measurement.
Just send us your inquiry and we will supply you with an detailed offer and the solution for your measuring problem.
A range of standard sensors you will find in our Online-Shop:
www.temperature-shop.eu
There you will also get more information about our range of temperature measuring technics:
- Temperature / Humidity Sensors
- Thermocouple Connectors
- Digital Thermomters
- Infrared Thermomters
- Stationary Pyrometers
- Controllers
- Data Loggers
- Hygrometers
- Transmitters
|
|
|
|
|
|
Thermocouple Assemblies - Components and Descriptions
Conax Technologies thermocouple assemblies represent the culmination of 50 years experience in the design and manufacture of temperature sensors. Conax Technologies thermocouple designs have proven their durability and reliability in applications ranging from large industrial processing plants to highly specialized laboratory testing and validation. Our extensive knowledge of the science of temperature measurement and the physical properties of materials used for sheathing and insulation enables our sales engineers to recommend the most effective solutions to your application needs.
Conax Technologies thermocouple assemblies offer a wide variety of termination styles and mounting fittings, as well as extensive choices in sensor calibration, sheath diameter and sheath material. This section outlines the key choices needed to specify the correct Conax Technologies part description for your needs. In each case, you will be asked to select the:
*sensor calibration
*sheath material and size
*tip configuration
*termination style
*optional mounting configuration
*sheath length
If at any time you require assistance, call 1-800-223-2389.
|
|
In oder to meet with all applications, this new range is composed of thermocouple probes with connection head, heat resisting steel sheath, mounted on cable or malleable mineral insulated, with a measuring range from –40 to +1100°C.
The new range is also composed of Pt100 probes with standard connection head, threaded compression fitting, contact, ambient end, for food industry, penetration and with a measuring range from –40 to +400°C.
A large choice of accessories ( mounting brakets, compression fittings, connectors, cables ….) and converters offered by KIMO allow you to enlarge thermocouple and Pt100 working conditions.
Join our distribution network all over the word....Contact us !
|
|
- Tip-sensitive (260°C) feature fast-responding copper tip in stainless sheath.
- Mineral insulated (600°C): Stable and rugged for demanding industrial environments.
- High temperature (850°C): Laboratory grade precision in an industrial probe.
- Diameters options include 0.125", 4 mm, 0.188", 0.215", 6 mm, 0.250"
- Single and dual elements
- Wide selection of adjustable fittings, thermowells, and connection heads available from stock
- Cut-to-length option lets you adjust probe length in the field
|
|
K, T, J and E Thermocouple Types
Made from Class 1 Tolerance Wire
PFA Insulation. (max. 260°C)
Kapton Insulation (max. 315°C)
Glass Braid Insulation. (max. 480°C)
1 and 2m Lengths Standard
Max Service Temp for Connector Body 220°C
|
|
Magnetic surface thermocouple
Magnetic surface probe
Calibration Type K.
Measures surface temperature of ferrous materials such as bearings on induction heaters.
Magnet diameter Ø 14mm.
Response time 7 sec.
Maximum temperature at tip 220°C
|
|
| ... products without technical information |
| |
•High-speed response time 100ms/ 90%
•Waterproofing ability in compliance with IP67
•High heat resistance up to 70°C of ambient temperature
•High noise resistance and accurate temperature measurement with stable operation due to SUS body and silicon lens
•Analog output of 4-20mA highly resistant to noise
•Cylindrical shape enabling installation in a limited space
•Temperature measurement range: 0-400°C (SA-80T-4A)
•Area size: φ80mm/ 500mm
|
|
|
|
|
|
thermoMETER: Precise non-contact temperature measurement from -40 to 1,800°C
The thermoMETER product group is targeted at industrial users. The infrared sensors comprise eleven products for stationary use. Amongst others, this includes products such as thermoMETER CT, which has external electronics. This sensor operates in temperatures from -40°C up to +975°C. This also includes the CT laser, which uses an integrated laser optical system to mark actual spot sizes at every distance. The CTglass version of this laser sensor is designed for use in glass production. The miniature sensors in the thermoMETER CS and CS micro series have integrated electronics located in the sensor head in the case of theCS, and directly integrated in the cable for the CS micro. This is particularly beneficial if space is restricted. The range also includes special sensors for use at high ambient temperatures of up to 250°C and for very high object temperatures of up to 1,800°C. A sensor with a response time of less than 3ms is also available very fast processes. To round off the range, an extensive list of accessories are provided for all sensors. These include various optical systems, air purge units, mounting aids and solid cases.
|
|
|
ATI Models Q45H62 and Q45H63 are reagentless and designed for on-line monitoring and control of chlorination systems. It is available in two versions: a free chlorine monitor for drinking water and cooling water, and a combined chlorine monitor ideally suited for “chloraminated” drinking water. The combined chlorine system can also be used in wastewater effluents where sufficient ammonia is present prior to chlorination to result in a predominantly monochloramine residual. Unlike on-line colorimetric and most amperometric monitors, Q45H systems utilize a membrane-covered polarographic sensor that does not require the addition of chemical reagents. The Q45H system has no moving parts, so there are no pumps or motors that burn out or tubing breaks that create maintenance nightmares. All normal maintenance items are included with each system.
|
|
|
EX900 Kit Complete with ExStik® Chlorine meter, pH electrode, ORP electrode, protective sensor cap, 5 packs of 10 reagent tablets (50 tests), 5 plastic sample cups, weighted stand, pH 4, 7 & 10buffer packs, four SR44 button batteries, carrying case, and neckstrap
|
|
Double-channel measuring and control instrument for free chlorine and pH-Value - additionaly ORP optional
- Double measurement of free chlorine and pH -optionally with additional ORP measurement
- Easy and safe operation by plain text menu guidance
- Log book function
- Graphical trend display of the last 3 h
description
The dialog W 2 CL2 PR R is a sophisticated instrument for the precise measurement and control of the chlorine concentration and the pH-value - additionally an ORP measurement is optional. It is available in a wall mounted housing.
|
|
The PCA 330 series of analyzers check pH/ORP and chlorine levels in applications such as pools and spas, drinking water and influent and effluent discharge of water to ensure public safety, prevent waste and protect the environment by reducing overdosage.
Features:
• pH regulation with both ON/OFF and proportional controls
• Separate alarms can be set for pH and chlorine controls
• Parameters can be sent through SMS
• Large graphical display with backlight
• User-friendly interface
• Can store up to 3500 data, that can be displayed or downloaded to a PC
|
|
| ... products without technical information |
| |
|
|