HIGH-TECH replacement for VA METERS
The MASS-VIEW® flow meter series are a digital alternative to the conventional variable area meters. The MASS-VIEW® flow meter series incorporates a digital bar graph of actual gas flow as well as indicating flow units, gas type and totalised figures.
The MASS-VIEW® series operates on the principle of direct thermal mass flow measurement. It offers a standard accuracy rating of ± 2%RD if the flow is higher than 50% of it’s maximum full scale and ±(1%RD + 0.5%FS) on lower flows, flow ratings from 0.2 up to 200 ln/min, and handles pressures up to 10 barg. The MASS-VIEW® incorporates the latest OLED technology, which gives a brighter readout than LCDs, can be viewed from virtually any angle and has fast signal response times. Alarm settings and the selection of a gas/range are accessed via menu. An analog output signal enables data logging against various parameters and full accountability of gas flow.
> Features
Clear indication in:
- actual flow rate (bar graph and value)
- desired flow units
- type of gas
- totalized flow
- Bright, wide-angle OLED display
- Freedom from parallax error
- Virtually independent of pressure and temperature variations
- Low pressure drop
- Wide flow ranges
- Fast response
- High accuracy
- Alarm and counter functions (2 alarm contacts available on meters)
- Analog (0..5 Vdc) and digital communication (Modbus-RTU, RS-232 interface)
- Configurable password protection
- 7 pre-installed gases available (Air, N2, O2, Ar, CO2, CH4, C3H8 or H2 or He)
- 4 selectable ranges (100%, 50%, 25% and 10% of maximum fullscale range)
- Digitally calibrated
- 3 year warranty
|
|
Digital alternative for a VA meter with totaliser and alarm functions.
MASS-VIEW(r) has an OLED display showing:
- actual flow rate (bar graph and actual value or percentage)
- desired flow units
- type of gas (7 pre-installed gases)
- totalized flow
- min. and/or max. alarm
Other features are:
- Freedom from parallax error
- Virtually independent of pressure and temperature variations
- Low pressure drop
- Wide flow ranges
- Fast response
- High accuracy
- Alarm and counter functions (2 alarm contacts available on meters)
- Analog (0..5 Vdc) and digital communication (Modbus-RTU, RS-232 interface)
- Configurable password protection
- 7 pre-installed gases available (Air, N2, O2, CO2, Ar, CH4, C3H8) or He or H2
- 4 selectable ranges (100%, 50%, 25% and 10% of maximum fullscale range)
- Digitally calibrated
- 3 year warranty
You can order these instruments online and your order is shipped within two working days.
|
|
Digital alternative for a VA meter with totaliser and alarm functions.
MASS-VIEW(r) has an OLED display showing:
- actual flow rate (bar graph and actual value or percentage)
- desired flow units
- type of gas (7 pre-installed gases)
- totalized flow
- min. and/or max. alarm
Other features are:
- Freedom from parallax error
- Virtually independent of pressure and temperature variations
- Low pressure drop
- Wide flow ranges
- Fast response
- High accuracy
- Alarm and counter functions (2 alarm contacts available on meters)
- Analog (0..5 Vdc) and digital communication (Modbus-RTU, RS-232 interface)
- Configurable password protection
- 7 pre-installed gases available (Air, N2, O2, CO2, Ar, CH4, C3H8) or He or H2
- 4 selectable ranges (100%, 50%, 25% and 10% of maximum fullscale range)
- Digitally calibrated
- 3 year warranty
You can order these instruments online and your order is shipped within two working days.
|
|
|
Bronkhorst High-Tech developed a field bus based pc-board for their mass flow metering and control solutions featuring self-diagnostics, alarm and counter functions, digital communication and remotely adjustable control settings. The digital "multibus" Mass Flow Meter can be equipped with on-board interface board with DeviceNet, Profibus-DP, Modbus or FLOW-BUS protocol. The newest digital Mass Flow Meters of the Select Series offer Multi Gas / Multi Range functionality featuring greater flexibility for user selection of both flow ranges and gas types, maintaining high accuracy and turndown range for measurement and control. Thanks to this feature users of the Select series can rescale their instruments on site, saving time (and money) for mounting and dismounting. For the convenience of the user, Bronkhorst High-Tech has developed a free and easy-to-use software tool called "FlowTune" for changing the configuration of Select instruments.
|
|
|
|
|
|
The latest product line developed by Teledyne Hastings Instruments is the digital version of the high capacity flow instruments. These new digital instruments allow measurement and/or control up to 10,000 slm. The new line complements the existing lower flow Digital Metaline(R) (5 sccm to 30 slm).
The two product lines, Digital Metaline and the new high capacity digital flow instruments, offer flow meters and controllers from 5 sccm to 10,000 slm, with superior accuracy. The lower flow Digital Metaline units have all-metal seals. A 4µ-inch Ra finish is available for flow rates up to 10 slm. Multiple gas calibrations and stored gas conversion factors are key features that set these instruments apart from the analog versions.
Both the Digital Metaline and the high-capacity digital flow instruments feature flexible operation with ±12, ±15 or 24 VDC power supply and transparent operation in analog or digital modes. All digital units are available with RS232 or RS485 interface with baud rates up to 19.2 kbaud. In addition, the instruments offer convenient self-diagnostics including warnings and alarms for flow, sensor, and valve status.
|
|
|
|
|
|
The latest product line developed by Teledyne Hastings Instruments is the digital version of the high capacity flow instruments. These new digital instruments allow measurement and/or control up to 10,000 slm. The new line complements the existing lower flow Digital Metaline(R) (5 sccm to 30 slm).
The two product lines, Digital Metaline and the new high capacity digital flow instruments, offer flow meters and controllers from 5 sccm to 10,000 slm, with superior accuracy. The lower flow Digital Metaline units have all-metal seals. A 4µ-inch Ra finish is available for flow rates up to 10 slm. Multiple gas calibrations and stored gas conversion factors are key features that set these instruments apart from the analog versions.
Both the Digital Metaline and the high-capacity digital flow instruments feature flexible operation with ±12, ±15 or 24 VDC power supply and transparent operation in analog or digital modes. All digital units are available with RS232 or RS485 interface with baud rates up to 19.2 kbaud. In addition, the instruments offer convenient self-diagnostics including warnings and alarms for flow, sensor, and valve status.
|
|
Reliable measurement systems are required for process-related monitoring and control of flow velocity. These must be resistant to environmental influences.
Technology
SCHMIDT® Flow Sensors for air and gases manage without moving parts, exploit the hermal measurement principle consequently and gain from the latest thinfilm and semiconductor technology. Highly integrated circuits and microprocessors technology have led to highly sophisticated sensors who compare favourably with any economic demand.
Special features of SCHMIDT® Flow Sensors:
* No moving parts = no wearing
* Very high turn-down ratio
* Quick response time
* Small pressure loss
* Ideal for very small flow velocities
Applications
* Heating, ventilation and air-conditioning technology
* Environmental technology
* Clean-room technology
* Process technology
* Compressed-air
* Medical technology
|
|
|
|
|
|
initial smallest measurable flow rate:
0.2 m/s
terminal flow rate:
30 m/s; 60 m/s; 120 m/s; 150 m/s; 180 m/s; 200 m/s
working temperature range:
-10° C... 140 °C
maximum working pressure:
up to 16 bar above atmospheric
materials in contact with the medium:
stainless steel; glas; epoxy resin
probe with diameter 10 mm in different lengths from 165 mm up to 965 mm
alternatively with / without transducer
====================================================
Compact units for use in Ex-applications:
for gas: Ex II 1/2 G Ex d e [ia] IIC T4 and
for dust: Ex II 1/2 D Ex iaD20/tDA21 IP6x T135°C
sensor for use in category 1 (Ex-zone 0 rsp. 20)
transducer housing for use in category 2 (Ex-zone 1 rsp. 21)
probe with diameter 10/15 mm in different lengths from 165 mm up to 1465 mm
initial smallest measurable flow rate:
0.2 m/s
terminal flow rate:
30 m/s; 60 m/s; 120 m/s; 150 m/s; 180 m/s; 200 m/s
working temperature range:
-10° C... 60 °C; 130 °C; 140 °C (dependent on the category and the temperature class)
maximum working pressure:
up to 16 bar above atmospheric
materials in contact with the medium:
stainless steel; glas; epoxy resin
|
|
|
|
|
|
SCHMIDT® Flow-sensor SS 20.260 for process technology
For the employment in process technology the latest SCHMIDT® flow sensor SS 20.260 offers three crucial upgrades compared to his forerunner. With an expanded measuring range of 0 … 50 m/s the sensor can be applied for flow rate control in a wide range of systems. Many processes require the measurement of heated gases and therefore an enhanced operating temperature. Depending on the configuration of the SS 20.260 it is up to 120 °C. The temperature can be measured with an additional linear output and no separate sensor is required any more. The unit is ro-bust due to a chamber in which the sensing element is protected against impacts. The stainless steel sensor tube is available in different length and thus can be placed at the correct position regardless of the size of the duct. Two LED’s indicate the correct operation or inform about wrong supply voltage or sensor defects.
Applications: Flow measuring in air ducts, volume flow measur-ing in test benches, control of combustion air of oil, wood, gas or coal burners, flow control in cool-ing or drying constructions.
Technical data: Immersion sensor with integrated transducer.
Use of sensor: Free air and guided air in ducts from 25 to 1.000 mm (1 to 40 inch).
Medium: Air, Nitro-gen, Argon and other non-burnable gases. Measuring ranges: 0 … 2.5/10/20/40/50 m/s.
Pressure: Atmospheric.
Power supply: 24 VDC / power consumption only 30 mA.
Output: 0 … 10 V / (0)4 … 20 mA linear.
Functional display: 2 Status LED’s
|
|
|
|
|
|
Sierra® offers three types of Immersible (Insertion) mass flow instruments for gas, liquids and steam flow measurement applications in small to very large pipes up to 200". Our Heavy-Industrial Thermal mass flow meter s are ideal for the roughest industrial environments and our line of Light-Industrial Thermal mass flow meters for a cost-effective mass flow measurement solution for Compressed Air and ALL inert industrial gases and methane (Natural Gas).
Our Heavy-Industrial Thermal mass flowmeter products are designed for the most demanding industrial gas mass flow measurement applications. Featuring heavy-duty 316 stainless steel wetted materials, no moving parts and digital signal processing, our Heavy-Industrial Thermal mass flow meter line is the answer for the roughest industrial environments.
We designed our Light-Industrial Product Line specifically to provide a cost-effective mass flow measurement solution for ALL inert industrial gases and methane (Natural Gas). The most common customer applications are air, nitrogen, and methane. Because of the small footprint, our Light-Industrial products, Boiler-Trak™, Accu-Flo™ Model 600, Fast-Flo™ Model 620S, & Accu-Mass™ Model 730 are a popular choice for Original Equipment Manufacturers (OEM's) who need an economical solution and have space constraints. Sierra's Light-Industrial products deliver turndown and accuracy at a price that can’t be beat.
|
|
The product line of Bronkhorst High-Tech Mass Flow Meters / Controllers is now extended with a compact readout/control module for local indication and operation. The new R/C-module is offering a modern, economical alternative for peripheral Readout/ Control electronics with integrated power supply. It complies with the demand for local indication of the actual flow-rate and/or totalised fluid consumption (simultaneously).
The module also features local operation, i.e. change of setpoint, counter reset, setting of engineering units, fluid name and tag number, etc. Four push-buttons at the right side of the device give access to a user-friendly menu. The bright 1.6” display is clearly visible over a wide angle, due to state-of-the-art OLED-technology. The weatherproof (IP65) housing makes the module suitable for use in industrial areas and the module can be mounted on the instrument or, using an optional mounting kit, on an adjacent wall or panel and on the pipework.
|
|
|
|
|
|
measuring tube inside diameter:
8 mm; 16 mm; 21.6 mm; 27.2 mm; 35.9 mm; 41.8 mm
whitworth tapered pipe thread / cutting ring tube connection (TA Di 8 mm)
initial smallest measurable flow rate:
0,04 m³/h (0,6 l/min) in Di 8 mm
terminal flow rate:
741 m³/h (12350 l/min) in Di 41.8 mm
working temperature range:
-10 °C ... 140 °C
maximum working pressure:
up to 16 bar above atmospheric
materials in contact with the medium:
stainless steel; glas; epoxy resin, Viton
explosion-proof type of protection:
Category 1G, 1D (Zone 0, Zone 20); Category 2G, 2D (Zone 1, Zone 21)
In measuring tubes with inside diameter bigger than 8 mm the input / output section is already integrated
alternatively with / without integrated transducer
====================================================
Compact units for use in Ex-applications:
for gas: Ex II 1/2 G Ex ia/d e [ia] IIC T4 and
for dust: Ex II 1/2 D Ex iaD20/tDA21 IP6x T135°C
sensor for use in category 1 (Ex-zone 0 rsp. 20)
transducer housing for use in category 2 (Ex-zone 1 rsp. 21)
measuring tube inside diameter:
8 mm; 16 mm; 21.6 mm; 27.2 mm; 35.9 mm; 41.8 mm
whitworth tapered pipe thread / cutting ring tube connection (TA Di 8 mm)
initial smallest measurable flow rate:
0,04 m³/h (0,6 l/min) in Di 8 mm
terminal flow rate:
741 m³/h (12350 l/min) in Di 41.8 mm
working temperature range:
-10° C... 60 °C; 130 °C; 140 °C (dependent on the category and the temperature class)
maximum working pressure:
up to 16 bar above atmospheric
materials in contact with the medium:
stainless steel; glas; epoxy resin, Viton
|
|
|
|
|
|
Sierra® Heavy-Industrial Thermal mass flowmeters are designed for the most demanding industrial gas mass flow measurement applications. Featuring heavy-duty 316 stainless steel wetted materials, no moving parts and digital signal processing, our Heavy-Industrial Thermal mass flow meter line is the answer for the roughest industrial environments.The Model 640S Steel-Trak™ is an insertion probe design and our Model 780S Flat-Trak™ is an inline design featuring an integrated dual-plate flow conditioning element (Flow=Trak™) that allows the instrument to maintain top performance in heavily constrained piping environments where long, straight pipe runs simply do not exist. All models feature DIRECT mass flow measurement and Sierra's Smart Electronics Package for field-rangability, flow-range adjustment, and meter validation and diagnostics.
UNIQUE PRODUCT FEATURES
- 316SS construction
- Range of process connections
- Field Validation/Configuration-
- 2% reading accuracy
- Very large installed base
- In-line flow conditioning
-Meters all process gases
-Removable probe for recalibration and service
-Meters all process gases
- ¾” diameter insertion probe (640S Product Line)
|
|
Teledyne Hastings Thermal Mass Flowmeters and Mass Flow Controllers are designed for the precise measurement and control of vacuum and gas flows.
The current Models HFM Thermal Mass Flow meter and HFC Thermal Mass Flow Controller represent the culmination of more than 60 years of experience in manufacturing quality mass flow instruments. The basic design incorporates removable/replaceable components to provide users a low cost of ownership, maximum flexibility, and reduced downtime.
The heart of the system is a replaceable sensor which virtually eliminates long downtimes due to clogging, the most common cause of failure in the industry. The modular design also offers adjustable range capabilities, in-line filtration, and replaceable electronics to allow users maximum flexibility in adjusting their system for changing requirements. Current designs can accommodate flow rates from 10 SCCM to 15,000 SLPM, fast responding or zero overshoot electronics.
|
|
|
Bronkhorst High-Tech Mass Flow Meters are made to customers’ specification, in various styles, suitable for use in laboratory, industrial environment and hazardous areas. EL-FLOW series Mass Flow Meters and Controllers for gas applications have a housing designed for laboratory and clean processing conditions. The Mass Flow Meters of the IN-FLOW series are of weatherproof design (IP65) for use in pilot and production plants in industrial environments (ATEX Zone-2). The Mass Flow Meters of the EX-FLOW series are suitable for gas flow applications in hazardous environments. The intrinsically safe measuring head is tested according to ATEX Zone-1 (protection II 2 G EEx ib IIC T4). Bronkhorst Mass Flow Meters can be supplied in ranges starting from 0,02…1 mln/min up to 11000 m3n/h air-equivalent, with pressure rating between vacuum and 700 bar.
|
|
The Hastings flowmeter’s basic design incorporates removable/replaceable components to provide users a low cost of ownership, maximum flexibility, and reduced downtime.
The heart of the system is a replaceable sensor which virtually eliminates long downtimes due to clogging, the most common cause of failure in the industry. The modular design also offers adjustable range capabilities, in-line filtration, and replaceable electronics to allow users maximum flexibility in adjusting their system for changing requirements. Current designs can accommodate flow rates from 10 SCCM to 15,000 SLPM, fast responding or zero overshoot electronics.
|
|
|
Bronkhorst High-Tech offers the most extensive product range of thermal mass flow meters and controllers for gases and liquids on the market. Numerous styles of both standard and bespoke instruments can be offered for applications in laboratory, industrial and hazardous areas. The full scale measuring range for these instruments can be selected between 0-1 mln/min and 0-10000 m3n/h for gases and 0-30 mg/h up to 0-20 kg/h for liquids. Bronkhorst's Coriolis Mass Flow Meters/Controllers for gases and liquids have a measurement capability between 20 g/h and 600 kg/h. The most recent development is a series of ultra-compact, chip-sensor based instruments for gas flow and pressure measurement and control.
|
|
The ST50 Flow Meter is an accurate, easy to install, no moving parts solution for measuring and controlling air, compressed air and nitrogen flow. ST50 utilizes FCI proven thermal dispersion technology to provide direct mass flow measurement resulting in higher performance at a lower cost than orifice plates, DP, Vortex shedding and other thermal devices. The meter installs in line sizes ranging from 2 to 24 inches [51 to 610mm] with 1/2" or 3/4" NPT.
The ST50 uses precision, lithography structured platinum RTD sensors embedded in FCI's equal mass small diameter, all metal thermowells. Combined with microprocessor electronics and precision calibration, the ST50 achieves excellent accuracy, fast response and virtually maintenance free operation.
|
|
|
|
|
|
AALBORG®'s enhanced model GFM is a low cost, self-contained THERMAL MASS FLOW METER designed to accurately measure the flowrates of gases.
A tiltable LCD readout is built into the top of the meter. Readings are in direct engineering units in terms of specific gases. Remote reading installations are possible by means of an optional extension wire supplied with a modular phone plug.
Flowrates are unaffected by temperature and pressure variations.
Aluminum and stainless steel models are offered. Zero and span adjustments are conveniently accessible from the outside, a dip switch is added for external adjustment of decimal point of the LCD readout.
Optional rechargeable battery kit is available for portability.
SPECIFICATIONS:
Accuracy: ± 1.5% of full scale.
Repeatability: ± 0.5% of full scale.
Maximum Flow: 1000 sL/min [N2].
Response Time: Typically 2 seconds to within ±2% of flow setting.
Maximum Gas Pressure: 500 psig / 34.5 bars.
Time Constant: 800ms
Transducer Input: ± 12 Vdc; 200 mA maximum.
Output Signal: 0 - 5 Vdc or optional 4 - 20 mA
|
|
The Brooks® line of analog thermal mass flow instruments is designed to meet the rigorous demands of our customers’ established and newly developing process applications. These devices continue to add to their expansive installed base due to their fast response, excellent accuracy and simple integration.
* Years of field-proven reliability
* Analog I/O allows for quick and easy system integration
* Elastomer seal option provides exceptional leak integrity and maximizes control valve shutoff dependability
* Ultra-high purity (UHP) and metal seal options ensure clean flow paths for contamination sensitive processes
* Globally approved for a variety of service areas
|
|
OMNI - F
The calorimetric principle of flow monitoring is based on two temperature sensors. One of these sensors is hearted constantly so that there is a constant difference in temperature between the two temperature sensors when the metering material is at a standstill
calorimetric
nominal diameter from DN 10
Ranges 1-150 cm/s
Pressure range PN 200
Temperature max. 70 °C
Stainless steel material
|
|
Calorimetr. Flow Monitor KAL-D
Calorimetric Flow Monitor KAL
Calorimetric Flowmeter /- monitors KAL-K
Calorimetric Flow Monitor f. Gases KAL-L
Calorimetric Flowmeter,-switch,-totalizer DVK
Differential Pressure Flowmeter RCD
Mass Flowmeter and /-controller for Gases MAS
Mass Flowmeter and /-regulator for Gases DMS
Mass Flowmeter for Gases MFC
Mass Flowmeter and /-regulator for Gases DMW
Therm. Mass Flowmeter for Gases KES
Mass Flowmeter and Counter PMS
Magnetic Inductive Flowmeter / -monitor PME
Magnetic Inductive Flowmeter/-monitor/-counter DMI
Magnetic Inductive Flowmeter/-monitor MID
Magnetic Inductive Flowmeter/-monitor PMG/PMH
Oscillation Flow Meters DOG
Ultrasonic Flowmeter DUB
Ultrasonic Flowmeter/-counter DUL
Vortex-Flowmeter,-switch DVZ
Vortex Flowmeter PWL
Universal Bussystem KOBUS
|
|
|
|
|
|
AALBORG®'s Model DFM MULTI-PARAMETER DIGITAL MASS FLOW METER with Digital Signal Processing provides accurate data on three different fluid parameters: flow, pressure, and temperature.
FEATURES:
- Multi-drop capability up to 256 units (for RS-485 option).
- Stores calibration data up to 10 different gases.
- Supports 10 engineering + user defined units.
- Programmable 12 digit Totalizer indicates total gas volume.
- Flow alarm limits for high & low gas flow.
- Pressure alarm limits for high & low gas pressure with relay output.
- Temperature alarm limits for high & low gas temperature with relay output.
- 4 button keypad & large 128x64 graphical LCD with back light.
- Digital (RS-232 or RS-485) & Analog outputs operate simultaneously.
- Internal conversion factors up to 32 gases.
- Automatic 0 adjustment.
- Self- diagnostics.
INTERFACE:
Features accessed via local keypad & LCD. The digital interface operates via RS485 (RS-232 available) & provides access to internal data including: flow, temperature, pressure reading, auto zero, totalizer & alarms settings, gas table, conversion factors & engineering units selection, dynamic response compensation & linearization table adjustment.
Analog interface provides 0 to 5Vdc, 0 to 10Vdc or 4 to 20 mA outputs for flow, pressure & temperature.
LEAK INTEGRITY:
1 x 10-9 smL/min of Helium maximum to outside environment.
|
|
|
|
|
|
XFM Smart Flow Meter with Optional Profibus Interface
Aalborg® is pleased to introduce the Model XFM, the latest addition to its programmable Thermal Mass Flow Meter line. This low cost "Smart" meter is designed for convenience (it can be programmed remotely), performance (unit stores calibration data for 1-10 gases and conversion factors for up to 32 gases), and accuracy (±1% of FS at calibration temperature and pressure).
The XFM's automatic sensor zero offset adjustment can be activated locally (maintenance push button) or remotely (via digital interface). Digital command technology starts, reads, or saves the current auto zero value.
Additional XFM Features:
Aluminum and stainless steel models.
Digital interface RS485, RS232 (with or without LCD displays), and optional Profibus DP (with I&M functionality).
Programmable Totalizer.
High/Low Flow Alarms
Self-Diagnostic Tests.
23 different Volumetric Flow or Engineering Units.
Internal or user-specific K-factors.
Aalborg®'s XFM Digital Thermal Mass Flow Meters are NIST traceably calibrated and individually programmed.
|
|
|
|
|
|
The FMA-1600A and FVL-1600A Series mass and volumetric flowmeters use the principle of differential pressure within a laminar flow field to deterime the mass flow rate. A laminar flow element (LFD) inside the meter forces the gas into laminar (streamlined) flow. Inside this region, the Poiseuille equation dictates that the volumetric flow rate be linearly related to the pressure drop along a fixed distance of the LFE. This, along with the viscosity of the gas, is used to accurately determine the volumetric flow rate. Separate absolute temperature and pressure sensors are incorporated and correct the volumetric flow rate to a set of standard conditions. This standardised flow rate is commonly called the mass flow rate and is reported in units such as standard cubic feet per minute (SCFM) or standard litres per minute (SLM).
Standard units include a 0 to 5 V output (4 to 20 mA optional) and RS232 communications. The gas select feature can be adjusted from the front of the keypad or via RS232 communications. Volumetric flow, mass flow, or absolute pressure, and teperature can be viewed or recorded through the RS232 connection. It s also possible to multi-drop up to 26 units on the same serial connection to a distance of 38 metres. These flowmeters can be powered by the optional battery pack FMA1600-BP for use in the field.
The FVL-1600A Series comprises volumetric flowmeters only. They do not measure or correct for absolute pressure or temperature. The FMA-1600A Series is recommended if the operating pressure is above 10 psig or if there is any restriction or backpressure in the applications.
|
|
Gas Flow Regulators & Switches with LC-Display and Totalizerfunction
Alongside numerous other possible uses, the red-y compact becomes an affordable alternative to the traditional variable area flowmeters.
In addition to its independence from the mains supply the compact series offer a clear and accurate indication of flow, insensitive to pressure and temperature changes, an integrated manual control valve and configurable switch functions.
- First mass flow meter with battery power
- At least two years of autonomy
- CMOS sensor technology
- On-the-spot direct reading, including bar graph
- Extremely compact unit
- Insensitive to pressure and temperature changes
- High accuracy and turndown ratio
- No moving parts
- Resistant to pressure bumps
- No restriction on installation position
- No inlet section required
- Optional 24 Vdc supply, manual valve & switch
- 3-year warranty
|
|
Gas Flow Meters with on-the-spot direct reading
Alongside numerous other possible uses, the red-y compact becomes an affordable alternative to the traditional variable area flowmeters.
In addition to its independence from the mains supply the compact series offer a clear and accurate indication of flow, insensitive to pressure and temperature changes, an integrated manual control valve and configurable switch functions.
- First mass flow meter with battery power
- At least two years of autonomy
- CMOS sensor technology
- On-the-spot direct reading, including bar graph
- Extremely compact unit
- Insensitive to pressure and temperature changes
- High accuracy and turndown ratio
- No moving parts
- Resistant to pressure bumps
- No restriction on installation position
- No inlet section required
- Optional 24 Vdc supply, manual valve & switch
- 3-year warranty
|
|
The ST75 from Fluid Components International (FCI) is an accurate, no moving parts, direct mass flow measurement and monitoring solution for fuel gases, air, compressed air, inert and other gas flows within industrial processes. It is available in nine different sizes for direct, in-line installation in line sizes from 1/4 to 2 inch [6 to 51mm].
Combining precision lithography structured platinum RTD sensors embedded in FCI's equal mass thermowells with microprocessor electronics and precise actual gas calibration, the ST75 achieves outstanding flow measurement performance. ST75's direct mass flow measurement eliminates costs and space of additional sensors required by inferred technologies.
|
|
The FMA1000 Series industrial air velocity and temperature transmitter/indicator measures and displays air velocity as well as air temperature in research and development labs, HVAC applications, and other manufacturing processes. The sensor design is based on three RTD elements, one measures air temperature and the other two measure air velocity by measuring the heat loss from the RTD sensor as it cools down by the air flow.
The FMA1000 series offers many standard features such as display of air velocity and temperature, two analogue outputs corresponding to air velocity and temperature, high and low voltage alarm outputs, USB serial interface, and Windows® based data logging software. The FMA1000 displays the air velocity in different engineering units such as FPM, m/sec, miles/hour, and km/hour. The air temperature is displayed in °C or °F.
|
|
EE66 Series
Air Velocity Transmitter for measurement down to "0" m/s
EE66 air velocity transmitter series are designed for high accuracy measurement of lowest air velocities. It is the ideal solution for laminar flow control and special ventilation applications. The E+E thin film sensor is operating on an innovative hot film anemometer principle. This guarantees excellent accuracy for air velocity down to almost 0 m/s, which is not possible for conventional anemometers with commercial temperature sensors or NTC bead thermistors
EE66 series are available with current or voltage output, the measuring range and the response time can be selected with jumpers by the user.
Measuring range: 0...1 m/s; 0...1.5m/s; 0...2m/s (adjustable by jumpers)
Response time: typ. 4s or typ. 0.2s (adjustable by jumpers)
Outputs: 0...10 V or 4...20 mA (adjustable by jumpers)
Supply: 24V AC/DC
|
|
|
|