{{#pushedProductsPlacement4.length}} {{#each pushedProductsPlacement4}}
{{product.defLight}}
{{#if company.requestButtonsVisibility.requestButtonQuestion == "ACTIVE"}}
{{elseif company.requestButtonsVisibility.requestButtonWhereToBuy == "ACTIVE"}}
{{/if}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{productPushLabel}}
{{#if product.newProduct}}
{{/if}} {{#if product.hasVideo}}
{{/if}}
{{/each}} {{/pushedProductsPlacement4.length}}
{{#pushedProductsPlacement5.length}} {{#each pushedProductsPlacement5}}
{{product.defLight}}
{{#if company.requestButtonsVisibility.requestButtonQuestion == "ACTIVE"}}
{{elseif company.requestButtonsVisibility.requestButtonWhereToBuy == "ACTIVE"}}
{{/if}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{productPushLabel}}
{{#if product.newProduct}}
{{/if}} {{#if product.hasVideo}}
{{/if}}
{{/each}} {{/pushedProductsPlacement5.length}}
filter reactor / DC/AC / three-phase / line
filter reactor

Current: 330 A
Voltage: 400 V

... performance in harsh working condition. Low Noise: Designed with low magnetic flux density,the reactors of high linearit.With powerful overload sheets, the reactor noise is low Characteristic of this ...

filter reactor / DC/AC / three-phase / with AC output
filter reactor
SKS-OCL-0020-AL-4

Current: 100 A
Voltage: 400 V

OCL series connection line reactor/ chokes are placed in series with electrical equipment to introduce a specific controlled impedance to the AC circuit. This series are applied at AC drive output side to suppress inrush ...

filter reactor / high dv/dt / three-phase / line
filter reactor
SKS AEER series for regenerative drive

Current: 500 A
Voltage: 400 V

... Iron core reactor Insulation: F Function: Filter reactor for the PV system ,improve power quality Impedance: 12% Installation: Serial/parallel Description of LCL Four-Quadrant Inverter (regenerate ...

filter reactor / three-phase / line / motor
filter reactor

Current: 8 A - 200 A
Voltage: 400 V

... mounting options of the line reactors can be tailored according to the customer’s objectives and needs. Reactor features High quality materials. Windings made of Grad 2 (double enamelled) copper wire, ...

three-phase reactor / single-phase
three-phase reactor

Current: 8000 A

The TRAFOX water cooled reactors use ethylene glycol for cooling, or a 0/10040/60% water mixture. For corrosion resistance, 30/70% inhibitor enriched coolants are recommended. The maximum liquid temperatures are 90 °C ...

three-phase reactor / line
three-phase reactor
230LRT series

Current: 9 A - 101 A

Three phase line reactors for electrical motors Standards: EN 61 558-2-20, IEC 60 989 Application: for motors 3 x 230V - line reactor impedance: 4% Protection class: prepared for protection ...

three-phase reactor / line
three-phase reactor
400LRT series

Current: 5 A - 85 A

Three phase line reactors for electrical motors Standards: EN 61 558-2-20, IEC 60 989 Application: for motors 3 x 400V - line reactor impedance: 4% Protection class: prepared for protection ...

three-phase reactor / line
three-phase reactor
500LRT series

Current: 4 A - 65 A

Three phase line reactors for electrical motors Standards: EN 61 558-2-20, IEC 60 989 Application: for motors 3 x 500V - line reactor impedance: 4% Protection class: prepared for protection ...

three-phase reactor / line
three-phase reactor
690LRT series

Current: 3 A - 98 A

Three phase line reactors for electrical motors Standards: EN 61 558-2-20, IEC 60989 Application: for motors 3 x 690V - line reactor impedance: 4% Protection class: prepared for protection ...

three-phase reactor / low-loss / iron-core / filter
three-phase reactor

... must be taken into account in the linearity and the saturation behavior of the reactor because the crest factor gets larger with increasing harmonic currents. Our reactors are made with special air gap ...

Rogowski coil / three-phase / single-phase / flexible
Rogowski coil
JRF MOI PU series

Current: 250 A - 6000 A
Voltage: 333 mV

... Rogowski coil technology offers low phase shift error, inductance and excellent linearity while largely immune to electromagnetic interference and pulsed DC, providing a high rate of accuracy. JRF-MOI-PU ...