• Power supply: from 24 to 230Vac;
from 12 to 110Vdc (with converter)
• Rotation speed: from 1s to 800h
• Available contact: from 1 to 20
• Available cams: screw adjustable, pins
cam, fix cams cutted or injected as
per customer diagram
• Mounting: wall mounted, panel mounted,
DIN rail 35mm |
|
Wide range of versions:
• Power supply: from 24 to 230Vac;
from 12 to 110Vdc (with converter)
• Mono and multiscale
• Mounting: wall mounted, panel moun
ted, DIN rail 35mm
• Connections: screw, 8 pins, 11 pins,
faston |
|
Wide range of versions:
• Mono and multivoltage
• Monoscale, biscale and multiscale
• Mono and multifunction
• Mounting: wall mounted, panel mounted, DIN rail 35mm
• Dimensions: modular 17,5 and 22,5mm, frontal 38x38, 38x48, 48x48mm
• Connections: screw, 8 pins, 11 pins, faston |
|
SB1// D94.61:
• For automatic defrosting of industrial refrigeration plant, commercial
visicoolers and display counters.
FEATURES:
Pre-set number of defrost cycles per day: 1, 2, 3, 4, 6.
Adjustable defrost period with variable profile cam.
Independent power supplies for synchronous motor and for switches
High contact rating (SPDT).
Safety guard for wiring terminals in accordance with CEI 23 – 11 (for
SB1).
ENEC – 03 approval
SB3// D94.63:
• For automatic defrosting of industrial refrigeration plant, commercial
visicoolers and display counters.
FEATURES:
From 1 to 12 defrost cycles per day thanks to non detachable tabs.
Defrost time easily adjustable from 1 to 56 minutes.
Fan delay easily adjustable from 0 to 15 minutes (for SB3.82).
Independent power supplies for synchronous motor and for switches.
High contact rating (SPDT).
Safety guard for wiring terminals in accordance with CEI 23 – 11 (for
SB3).
ENEC – 03 approval. |
|
• Functions: Phase sequence-unbalancemissing; current sensitive relay
• With fixed or adjustable threshold
• Adjustable response time and hysteresis
• Power supply: mono, dual, multivoltage
• Dimensions: modular 17,5, 22,5, 45, 55, 70mm
• Mounting: wall mounted, DIN rail 35mm |
|
• Functions: emergency stop, two hand, contacts expansion, many
configurations available
• Power supply: 24Vac/Vdc;115,230Vac
• Safety category: 2, 4, IIIA, IIIC
• Dimensions: modular 22,5, 45mm
• As per CEE machine directive 89/392/CEE
• Norms: IEC 204-1, EN 60204-1, DIN/VDE 0113 |
|
• AC Gearmotor and stepper motor
• Many possibilities of coupling among motors and gearmotors
(as shown in our catalogue).
AC Motors
• Power supply: from 12 to 230Vac, 50 and 60 HZ
• Running torque: from 8 to 600 Ncm
• Output shaft speed: from 0,07 to 75 rpm |
|
• Many possibilities of coupling among motors and gearmotors (as shown in our catalogue).
Gearmotors
• Power supply: from 12 to 230Vac; 12 - 24 Vcc
• Ratios: from 25/3 to 22500
• Max efficiency power: max 4,8 W |
|
• Functions: emergency stop, two hand, contacts expansion, many
configurations available
• Power supply: 24Vac/Vdc;115,230Vac
• Safety category: 2, 4, IIIA, IIIC
• Dimensions: modular 22,5, 45mm
• As per CEE machine directive 89/392/CEE
• Norms: IEC 204-1, EN 60204-1, DIN/VDE 0113 |
|
PICO-GUARDTM
The patent pending PICO-GUARDTM system is a unique combination of control-reliable, non-contacting photoelectric and fiber optic technologies that provide a low-cost alternative to cumbersome and costly methods for machine safeguarding. The fibers can be easily piped to points requiring safeguarding with no electrical wiring required. The controller has four independent optical channels, offering the ability to safeguard multiple points with one controller. The optical elements require no electrical connection and no electrical energy is used at the optical elements - all electronics are at the controller. Optical elements can be used either as emitters or receivers to simplify installation.
PICO-GUARD offers a simpler way to guard doors, openings and dangerous areas, compared with mechanical safety interlock switches. Because PICO-GUARD uses only optical elements, it eliminates electrical contacts and other
failure-prone mechanical components, including actuators that have alignment issues. PICO-GUARD fiber optic safety interlock switches are also several times smaller and several times lighter than mechanical switches. |
|
• Output torque: from 80 to 600 Ncm
• Ratios: from 20/3 to 18,000,000
• Revolution time: from 1s to 800h
• Frictions: unidirectional, bidirectional |
|
Wide range of versions for all industrial
automation fields:
• Industrial washing and dry cleaning
• Driers; industrial ironing machines
• Water cleaning; bottling; packing
• Industrial process machines in general
• Genset controller. |
|
Digital high counting speed counter
• Power supply: mono or multivoltage from 24 to 230Vac, 24Vdc
• Display: 1, 2, 3, 4 digits
• Wide range of functions
• With or without display
• With or without memory
• Mounting: wall mounted, panel mounted, DIN rail 35mm
• Dimensions: modular 45mm, frontal 48x48, 48x96 mm
• Connections: screw, faston |
|
AC synchronous motor and Stepper motor
• Unidirectional and bidirectional
• Power supply: from 12 to 230Vac
• Running torque: from 0,08 to 4 Ncm
• Output shaft speed: from 375 to 600 rpm
Stepper Motor
• Bipolar stepper motor
• Supply voltage: 12 Vdc
• Full step: 24
• Running torque: fix at 4 Ncm among motors and gearmotors |
|
|
|