Available Temperature Range: -400°F to +350°F
continuous (to +400°F intermittent heat).
End Fittings: MS flared and flanged styles are
recommended. Other types available on request.
Bearing Styles: Ceramic hybrid ball bearings sizes 1¼”
through 12”. Stainless steel ball bearings sizes ¼” through
1”.
Materials: 316 stainless steel standard. Consult with
applications group for corrosive applications. Broad material
list available.
*** Linearity is density-dependent for a given meter.
Consult factory for details.
|
|
The CAT3 is a DC or AC powered, microprocessor
controlled transmitter. It outputs a pulse scaled per unit of
flow, and analog signal proportional to flow rate. The
CAT3 can be configured with High and Low alarms.
|
|
Low cost.
· Outstanding accuracy.
· Provides wide flow ranges (10:1 to 100:1 turndown ranges available).
· One piece 316/316L S/S Construction for most pressures.
· For use with unique Hoffer high pressure 316/316L or carbon steel mating flange kits,
supplied complete with SAE J429 Grade 8 high yield strength bolts and "O" rings.
· Operate over a wide range of temperatures.
· Sizes 1/4" through 2". Pressure ratings of 3,000, 6,000, 8,000, and 10,000 psi available
for most sizes.
· Larger sizes and pressures available upon request. Contact factory.
|
|
OUTSTANDING FEATURES
· Low cost.
· Outstanding accuracy.
· Provides wide flow ranges (10:1 to
100:1 turndown ranges available).
· Wide variety of process connections
available.
· Wide selection of construction
materials.
· Operate over a wide range of
temperatures and pressures.
|
|
The Hoffer Sanitary Design Turbine flowmeter is accepted as
meeting 3-A Sanitary Standard No. 28-03 for measurement of
process liquids where high sanitary standards are required.
Available in 11 sizes, ¼” to 3” with standard Tri-Clamp™
fittings, covering flow rates for 0.35 to 650 GPM.
|
|
The flowmeter pickup coil senses
the motion of the rotor and converts it
to a pulsing electrical signal which is
of a discrete digital nature. Three
basic pickup types are offered for use
with the MF Series which will satisfy
standard electrical interface
requirements for turbine flowmeters.
|
|
Paddlewheel flow meters for pipe sizes 1/2-8 inches
-High-quality ruby bearings for excellent low-flow performance and long life
-One easily-replaced moving part
-Pickup exerts no magnetic drag on the rotor
-Square-wave frequency output can connect directly to PLC’s or counter controls
-Indicator or transmitter can be mounted on the flowmeter or remote
|
|
1MX = Magnetic pickup coil with 1” riser on meter body for mounting of
enclosures and electronics.
1MX3/0=Magnetic pickup coil with 1" riser and enclosure Class I, Groups C & D.
PED-CE =PED-CE mark required for Europe requires the operating temperature and
pressure be given and will be marked on the housing.
CE = CE mark required for Europe.
|
|
The Hoffer Sanitary Design Turbine flowmeter is accepted as
meeting 3-A Sanitary Standard No. 28-03 for measurement of
process liquids where high sanitary standards are required.
Available in 11 sizes, ¼” to 3” with standard Tri-Clamp™
fittings, covering flow rates for 0.35 to 650 GPM.
|
|
Hoffer flow control
Controls turbine flowmeters
Of all the various types of flow transducers available to industry today. None are so universally applicable as turbine flowmeters. They continue to be the most common way to measure flow electronically and have the ability to measure available upon request offering detailed, technical information.
|
|
FLOW RANGE (Note 1)
Ranges shown are standard ranges — other ranges are available. Contact Hoffer Flow Controls Applications Group.
BEARING TYPES (Note 2)
—CB Hybrid Ceramic, Self-lubricating shielded ball bearings. Ball bearings must be used on CO2, may be used on H2O and never on H2O/Sand or CS.
—C Hard Carbon Composite sleeve bearings. For use on H2O only.
—T Tungsten Carbide sleeve bearings. Tungsten Carbide must be used on H2O/Sand and CS, may be used on H2O, and never used on CO2.
|
|
Hoffer inline turbine flowmeters are
velocity measuring devices, which is
to say they measure the average
velocity of a fluid flowing through
the body of the meter. See
Illustration 1 for details on the
construction of the Hoffer inline
turbine flowmeter. Mounted within
the body of a Hoffer liquid turbine
flowmeter is a vaned rotor.
|
|
PLASTIC IMPELLER FLOWMETERS FOR CHEMICALS
These flowmeters have a pulse out. Construction is simple. Rangability is good. Cost is low.
SRP and SRT flowmeters
-3/8 to 1 inch
-5-40 GPM max flows
-20-150 LPM max flows
-TFE or Polypro bodies
-Threaded ports
-High resolution rotors optional
-Ruby bearings
-Very high rangability
|
|
The Hoffer Sanitary Design Turbine flowmeter is accepted as
meeting 3-A Sanitary Standard No. 28-03 for measurement of
process liquids where high sanitary standards are required.
Available in 11 sizes, ¼” to 3” with standard Tri-Clamp™
fittings, covering flow rates for 0.35 to 650 GPM.
|
|
We are proud that you have selected a Hoffer Turbine Mini-
Flowmeter, the finest precision flow transducer on the market.
The Hoffer MF Series of Mini-Flowmeters are designed to meet the
need for a high quality low flow measurement device for service in
low to moderate viscosity clean liquids and for gas applications.
|
|
Hoffer flow control
Controls turbine flowmeters
Of all the various types of flow transducers available to industry today. None are so universally applicable as turbine flowmeters. They continue to be the most common way to measure flow electronically and have the ability to measure available upon request offering detailed, technical information.
|
|
OUTSTANDING FEATURES
· Low cost.
· Outstanding accuracy.
· Provides wide flow ranges.
· Wide variety of process connections
available.*
· Operate over a wide range of
temperatures and pressures.
· Exclusive use of hybrid ceramic ball
bearings provide superior life.
|
|
LC Turbine Flow Meters
- Sizes: 1/4" through 12"
- Flow Rates: 0.25 - 12,000 GPM
- End Connections: ANSI, NPT (¼ to 2"), Tri Clover, Flare Tube, Wafer
- Pressure Ratings: 150 - 2,500 ANSI
- Materials of Construction: Body: 304,316,316L SS; Rotor: 17-4 pH SS
- Bearing: Metal Ball, Carbide Sleeve, Cryo Ball, Fluorosint Sleeve
- Accuracy: Capable of ±0.25% of rate over 10:1 range
- Repeatability: Capable of 0.05% of reading over entire range
|
|
Honeywell VersaFlow Vortex
The VersaFlow Vortex 100 is the only vortex flow meter with integrated pressure and temperature compensation in 2-wire technology. The Vortex 100 provides reliable measurement of standard volumetric and mass flow of both conductive and non-conductive liquids, gases and vapors, even with fluctuating pressures and temperatures. VersaFlow vortex flowmeters deliver excellent long term stability due to their rugged construction.
Typical applications include:
Vapor and saturated steam measurement
Steam boiler monitoring
Compressor output monitoring
Measurement of industrial compressed gases
Measurement of conductive and non-conductive liquids
|
|
|
These vortex shedding flowmeters are designed for coolant or water flow from ¼ to 4 inch pipe sizes. Optionally, ¾ to 4 inch sizes have temperature transmitters. In ¼ and ½ inch sizes, 316 Stainless Steel bodies and Kalrez seals make it suitable for low viscosity corrosive fluids. They cost a lot less than mag meters and they are OK with high particulate. Simple, reliable and inexpensive.
|
|
Honeywell VersaFlow Vortex
The VersaFlow Vortex 100 is the only vortex flow meter with integrated pressure and temperature compensation in 2-wire technology. The Vortex 100 provides reliable measurement of standard volumetric and mass flow of both conductive and non-conductive liquids, gases and vapors, even with fluctuating pressures and temperatures. VersaFlow vortex flowmeters deliver excellent long term stability due to their rugged construction.
Typical applications include:
Vapor and saturated steam measurement
Steam boiler monitoring
Compressor output monitoring
Measurement of industrial compressed gases
Measurement of conductive and non-conductive liquids
|
|
OEM Flow sensor type 200
0.9 ... 150 l/min
The flow sensor of this range is based on the principle of Karman’s vortex trail. The shedding of vortices on the damming body in the flow is directly proportional to the speed of the flow. A piezoelectric paddle detects the generated vortex and analyses the values with the integrated electronic.
Alternatively, are versions with integrated temperature measurement with PT1000 is available.
|
|
¨ 5 Digit Rate Display, 8 Digit Totalizer Display.
¨ Local Magnetic or Remote Reset.
¨ 4-20mA Analog Output.
¨ Powered From Battery, DC Supply, 4-20mA Output
Loop, or AC Line.
¨ 20 Pt. Linearization Option.
¨ Isolated Scaled Pulse Output.
¨ Alarm Output for Rate or Total.
¨ Windows® Configuration Program.
¨ RS 232 Port for Configuration and Monitoring.
¨ Diagnostics for Pulse, Alarm and Analog output.
¨ Password Protection for Menu and Reset.
|
|
♦ Displays Rate & Total Simultaneously.
♦ 4½ Digit Rate Display, 8 Digit Totalizer Display.
♦ 4-20mA Analog Output.
♦ Powered From Internal Battery, External DC
Supply or 4-20mA Output Loop.
♦ 10 Pt. Linearization Available.
♦ Isolated Scaled Pulse Output.
|
|
The Nova-Flow Series of flow computers is a family of highly flexible, modular flow computers designed for
basic rate and total flow display, batch control for liquid and gas flow measurement, as well as for
thermal energy measurement. With more than 500,000 unique configurations possible, the potential
applications for these devices is almost limitless.
|
|
The flowcom compensates for flowmeter errors due to pressure or temperature variations and computes mass or standard volume flow rates for gases, steam or liquids. It can even do so for a pair monitoring stations. It also computes heat transfer rates and thermal-energy contents for heat transfer media or refrigerants.
As a two channel version, the flowcom can calculate balances between supply and return lines.
A particular advantage of the flowcom: It does not operate based on problematic equations, but integrates a number of permanently stored tables of the mass densities and enthalpies of commonly employed media.
Flowcom will compensate the infloence of temperature and pressure on virtually each flowmeter such as integrating pitot tubes, orifices, venturis, vortex meters, mag meters, ultrasonic flowmeters, PD-meters…
The flowcom communications software runs under Windows.
|
|
¨ DC or AC powered.
¨ Pulse and analog output scaled per unit of measure.
¨ Optional Hi and Lo alarms.
¨ Flowmeter Linearization.
¨ Factory configured when purchased with a Hoffer
flowmeter.
¨ Several Enclosure options.
¨ CE Compliant.
¨ Windows® Configuration Software
|
|
|
|