Type 1 surge arresters
Voltage: 5 V - 170 V
... Voltage Suppressors are designed to protect sensitive electronic components from high voltage, high-energy transients. High surge capability, low impedance, low clamping voltage, fast response time and small size make ...
Central Semiconductor
Voltage: 264, 255 V
Primary current: 25,000, 50,000, 100,000 A
High discharge capacity due to powerful creepage discharge spark gap Maximum system availability due to RADAX Flow follow current limitation Easy replacement of protection modules without tools due to module locking system with module ...
DEHN + SÖHNE
ETITEC Went surge arrestor is perfect for indoor applications. This protection corresponds to the IEC category I, II. The protection is made on the main distribution box, which stands as the first level of protection ...
ETI
Voltage: 280 V
Primary current: 10,000 A - 20,000 A
... Second Stage: Type 2 / Class 2 / C Class Surge Protection Devices (Surge Arresters) are circuit elements used in the secondary and / or lower secondary panels of ...
Liva Group
Voltage: 3 kV - 36 kV
Primary current: 5,000 A
Products are strictly in accordance with GB, IEC, IEEE and other standards Through Kema, CEPRI, XIHARI and other test reports It has excellent nonlinear volt ampere characteristics. Simple structure, no gap, small size, ...
jinniu electric
Voltage: 500, 600, 800, 1,000 V
Primary current: 20,000 A - 80,000 A
The By7 series Surge Protection are designed to protect against lightning surge voltages in photovoltaic power supply networks. These units must be installed in parallel on the DC networks to be protected ...
Primary current: 10,000 A
... female base connector (STC-PCB1B, sold separately). When snapped together, the data circuits pass thru the protector in a serial fashion from the four field side terminals to the four electronics side terminals. Terminals ...
SolaHD
Voltage: 1,000 V
Primary current: 0 A - 30,000 A
Lightning/ Surge Protector type 1 combine type 2 at 1000VDC to protect the solar PV circuit from over-voltage or directly lightning damage. The 1000V ...
Zhejiang Benyi Electrical Co.,ltd.
Voltage: 150 V - 1,200 V
Primary current: 20,000 A - 30,000 A
AC Power ETL recognized component certified to ANSI/UL 1449 3rd Edition products offer base with removable suppression module, local status indication and remote alarm contacts
Voltage: 230, 400 V
Primary current: 25,000 A
... by wiring via the multifunctional scr ew connection terminal (terminal L1 ́, L2 ́, L3 ́, and N ́ ) or else as serial wiring via the optional two-pole bus -bar connection (L1 to L1 ́ and ...
Leutron GmbH
Voltage: 0 V - 335 V
Primary current: 20,000 A
... voltage Uc : 335 V AC Max. discharge current Iimp : 12,5 kA Nominal discharge current In : 20 kA Level of Up protection under In : 1,3 kV
Product Item : - BHP15 Specification : - BHP-15 1P 1P+1 1P+N 3P 3P+1 3P+N DIN RAIL TYPE Applied counter Standards IEC61643 IEC61312-1,61643-1,61000-5-6 ...
Primary current: 10 A
... series are low-cost surge and lightning arrestors specially designed for airfield lighting application on runways, taxiways or aprons. They meet all international standards, and are efficient in protection against over ...
Voltage: 0 V
Primary current: 40, 50 A
1/4λ surge arrestors are used for protecting antenna equipment and transmission-receiver system against the damages caused by over voltage and induction voltage of lightning. The product ...
Voltage: 0 V - 40 V
... the DC power surge to achieve primary protection The attenuation coefficient of frequency meet 30dB Cost-effective Low Temperature rise No reverse connect protection function Mounting: PCB mounting, chassis ...
Voltage: 230, 440 V
Primary current: 50,000 A
Open circuit voltage: 1.5 kV
Product or component type Surge arrester Device short name PRF1 Device application Distribution Standards EN 61643-11 IEC 61643-11 Product certifications CE Poles ...
Voltage: 0 V - 5 V
Primary current: 5,000 A
... various interferences caused by the common ground transmission signal -The excellent lightning protection performance, built-in multi-level surge protection, large surge ...
3onedata Co.,Ltd.
Voltage: 0 V - 5 V
Primary current: 5,000 A
... various interferences caused by the common ground transmission signal -The excellent lightning protection performance, built-in multi-level surge protection, large surge ...
3onedata Co.,Ltd.
Voltage: 0 V - 5 V
Primary current: 0 A - 5,000 A
... interferences caused by the common ground transmission signal -The excellent lightning protection performance, built-in multi-level surge protection, large surge capacity, ...
3onedata Co.,Ltd.
... passed, while suppressing the lightning surges. The best possible grounding is provided using a ground lug terminal. 50Ohm surge protectors have an N connector and can be ordered ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining