Nominal voltage: 600 V - 1,000 V
Temperature: -20 °C - 80 °C
Nominal voltage: 60 V
Temperature: -40 °C - 85 °C
... Application range For commercial verhicles Wiring of electrical equipments in all trailers and semi-trailers Product features UV-resistant Resistant ...
Nominal voltage: 600 V - 1,500 V
Temperature: -40 °C - 100 °C
Electron beam cross-linked solar cables with reduced outer diameters ÖLFLEX® SOLAR XLS-R - halogen free electron beam cross-linked solar cable for durable and weather proof use in photovoltaic systems Optimised ...
Nominal voltage: 300 V - 500 V
Temperature: -50 °C - 100 °C
... Outer jacket: TPE Coolant resistant Low-temperature-flexible Hydrolysis and microbe-resistant Flame retardant Silicone-free UV-resistant PVC-free Oil resistance: ...
igus®
Nominal voltage: 300, 500 V
Temperature: -40 °C - 80 °C
Cross-section: 0.5 mm² - 16 mm²
... resistant to: oil, UV radiation, ozone, oxygen, weathering effects, hydrolysis, microbes, coolants, hydraulic fluids, acids, alkalis, greases, seawater and wastewater highly abrasion-resistant, ...
HELUKABEL
Nominal voltage: 500, 300 V
Temperature: -40 °C - 90 °C
Cross-section: 0.5 mm² - 25 mm²
... mm² CE Halogen-free, flexible cable, suitable for flexible and protected installation in the interior for door control or in protecting tubes for outdoor laying at the bogie, railway machines or as connection cable ...
Nominal voltage: 300, 500 V
Temperature: -50 °C - 90 °C
Cross-section: 0.25 mm² - 35 mm²
... installation, e.g. bogies, railway machines. Also for flexible application inside rolling stock, e.g. door systems. good ozone, UV and weather resistance good oil and fuel resistance fulfils fire protection requirements ...
Nominal voltage: 0 V - 90 V
Temperature: -50 °C - 125 °C
Single-Pair-Ethernet cable for robust indoor and outdoor use Marking for CATLine SPE Rugged 17399005: SAB BRÖCKSKES · D-VIERSEN · CATLine SPE Rugged 2xAWG26/7 1719-1620 CE Robust & weatherproof ...
Nominal voltage: 300 V
Temperature: -50 °C - 80 °C
Length: 1, 100, 500 m
... items (halogens); . the material is difficult to inflame and also self-extinguishing, smoke exposure is minimal. The cables are UV-resistant. AWG 20 (0,56 qmm) unshielded
Nominal voltage: 300 V
Temperature: -50 °C - 80 °C
Length: 1, 100, 500 m
... items (halogens); . the material is difficult to inflame and also self-extinguishing, smoke exposure is minimal. The cables are UV-resistant.
Nominal voltage: 300 V
Temperature: -30 °C - 105 °C
Length: 500, 1, 100 m
Standard Control Cable, flexible, colored conductors, AWG 18, UL-certified, PVC-jacket black
Temperature: -25 °C - 70 °C
Cross-section: 16 mm²
... . to: ○ EN 60332-1-2 Eca ○ IEC 60332-1-2 ○ NBN C30-004 F1 • UV-resistant • Insulation thickness 1,0 mm • Outer Diameter 7,5 mm • M4 ring cable lug ...
Temperature: -30 °C - 105 °C
... from -30°C to +105°C. The cable is UV-resistant and can be used for PoE/PoE+/PoE++ applications thanks to its conductor cross-section of AWG26/7. The cable type has been ...
Rubber cables Rubber cables are widely used when a specific flexibility or high mechanical stress is needed, they are used for connection of tools and mobile equipment or i.e., on construction sites ...
Nominal voltage: 300 V - 1,000 V
Temperature: -40 °C - 90 °C
Cross-section: 1.5 mm² - 240 mm²
Nominal voltage: 300 V - 1,000 V
Temperature: -40 °C - 100 °C
Cross-section: 0.14 mm² - 0.34 mm²
... E-MOBILITY electric cables. High temperature silicone cables T150, T180 Cross-linked cable. Type FHLR2GCB2C, FHL2G Automotive charging cable H05BZ5F, ...
Nominal voltage: 1,000 V
Temperature: -25 °C - 60 °C
The RVFV cables are the power cables for use on industrial sites and the upright columns of buildings. • conform to RoHS • resistant to aliphatic hydrocarbons conductor material ...
... series of rodent resistant designs to the family of LMR low-loss flexible coaxial cables. These new LMR-DB-RR products utilize a non-hazardous, non-toxic additive which deters rodents and other pests ...
Times Microwave Systems
Nominal voltage: 300 V
Temperature: -40 °C - 80 °C
Cross-section: 0.34 mm²
... pressure and roll-over resistance Low adhesion, Abrasion-resistant, Tear resistant Hydrolysis-resistant, microbe-resistant, and rot-resistant ...
Nominal voltage: 700, 125 V
Temperature: -20 °C - 60 °C
Data cable for marine and offshore usage Category 7a better than class Fa up to 1000 MHz UV-resistant reinforced data cable for transmission analog and digital signals ...
VOKA
... TSFLCGEWÖU Flat Medium Voltage reeling cable with integrated fiber optics. Type designation (N)TSFLCGEWOEU Flat Medium Voltage reeilng cable. Type designation: (N)TSKCGEWOEU Medium Voltage reeling ...
Temperature: -5 °C - 80 °C
Power supply for electrical applications and drives Transmission of large electrical currents Outer jacket valley-sealed extruded and high abrasion resistant Oil-resistant UV-resistant CFC-free REACH/ROHS ...
TSUBAKI KABELSCHLEPP
Nominal voltage: 600 V - 1,000 V
Temperature: -40 °C - 150 °C
Cross-section: 150 mm² - 400 mm²
Halogen-free, double-layer aluminium class 2 cable for Wind-Energy plants Application FRNC single core cable designed especially for fixed installations in the tower of wind energy plants. Construction ...
Brugg Kabel AG
Temperature: -25 °C - 75 °C
Length: 1,000 m
... polyester screen with a continuity wire and LS0H sheath. This is a telephone cable for indoor installations. Telecommunications cable Flame retardant Low smoke emission UV ...
CABLESCOM
Temperature: 0 °C - 90 °C
... operating temperature of conducter 90℃; Cables should have anti UV, anti cracking, weather resistance, anti mouse and anti ant performance. High stability High electrical strength, ...
Length: 100 m - 305 m
... Code: 85442000 D-FB Series Cable: Specifications: 5D-FB: 1.8mm CCA + 5.0mm FPE + 85%TC Braid + PE 7.7mm 7D-FB: 2.6mm CCA +7.3mm FPE + 85%TC Braid + PE 10.00mm 8D-FB: 2.8mm CCA + 7.8mm FPE+ 90%TC... Should the bulk ...
... special construction of Ecoflex 15 combines the excellent damping values of rigid 1/2 "cables with a rigid inner conductor with the ease of laying of flexible coaxial cables with inner strand conductors. ...
SSB-Electronic GmbH
Nominal voltage: 1, 600 kV
Cross-section: 25, 16, 10 mm²
... Conductor: Cu Material:UV STABILISED PVC Section: 10 mm²—25 mm² Application: indoor and outdoor, motorised vehicles, fork lifts, filed conveyor, in high quality ...
Nominal voltage: 1,500 V
Temperature: -40 °C - 250 °C
Cross-section: 95 mm² - 400 mm²
The TOPSOLAR PV AL 1500V solar cable is suitable for photovoltaic installations, both for underground structures and for outdoors structures. This cable is specially designed for the connection of photovoltaic ...
Nominal voltage: 600, 1,000, 1,500 V
Temperature: -50 °C - 115 °C
Cross-section: 120, 185, 240 mm²
... ready-to-install flexible wire replacement solution. Round IBS Advanced connect to the terminals of an electrical device without the need for additional accessories, such as angular connectors, spreaders, ...
Nominal voltage: 600 V - 30,000 V
Temperature: -5 °C - 90 °C
... installation, in the ground, for power stations, industry and distribution boards or subscriber networks, where mechanical damage to the cable is not expected (see DIN VDE 0298-1). The cables ...
Bayerische Kabelwerke
The GLS leads from hotset can be used at high temperature conditions of over 300 °C – when the use of copper cables is no longer possible. hotset offer a wide range of choice in cross-section, tracer ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining