Thermoset MIVI 8003 ensures an on-line viscosity measurement of any fluid at a required reference temperature.
PRINCIPLE :
The fluid is permanently drawn from the process brought at the required reference temperature, its viscosity measured, then re-injected in the main line.
ADVANTAGES :
• No extra installation
• Short response time: 2 to 5 min
• Insignificant maintenance : ½ day / year
• Small size
• Reliable and accurate
• Usual power : mains and pressurized air
• Optional density measurement
• Simple, Rugged
• Exproof approval : ATEX EEx d IIB T4...T6
OPERATING CONDITIONS :
• Maximal temperature at the cell: 200 °C
• Reference temperature: according to the requirement
• Maximal inlet pressure: 16 bar
• Maximal outlet pressure: 40 to 120 bar according to product viscosity
MEASUREMENT RANGE : (at reference temperature):
• 1 – 100 mPa.s ; 10 – 1000 mPa.s ; 100 – 10 000 mPa.s |
|
The Davenport PETPlus from Lloyd Instruments is a unique test instrument designed for the safe solvent-free intrinsic viscosity (IV) measurement of
moisture-sensitive PET. It can be operated in stand alone mode or with our powerful data analysis software package NEXYGENPlus PET.
Most IV test instruments use the solvent method. However, not only is this method expensive, but also involves the handling and disposal of toxic solvents. The PETPlus instrument by contrast offers significant cost and environmental benefits using a non-solvent method, which is kinder to the environment, and saves on the high cost of purchase and disposal of solvents.
Unlike other IV measurement instruments, the PETPlus can test polymers at virtually all stages of the process: from incoming resin, powder and granules, molten polymer, preforms, PET bottles and even re-ground material.
Tests can be completed in under 20 minutes. Rapid testing can be carried out using ancillary equipment for controlled sample collection and preparation.
The microprocessor controlled system provides high accuracy measurements, temp. control to ±0.1°C and storage of up to 600 results. An LCD displays multi-lingual instructions for the test as well as the results. An RS232 interface allows connection to a PC for fully automated software control and downloading of results.
Molten PET is extruded through a calibrated die by nitrogen gas under pressure and the LVDT probe movement against time is recorded and displayed. The system measures the optimum flow rate and calculates intrinsic viscosity. The PETPlus also measures the degradation factor and provides the mean and standard deviation for the batch. |
|
The TT-100® In-Line Viscometer is designed to provide years of trouble-free service in closed loop systems which require constant monitoring and associated control of product viscosity.
|
|
MIVI PROCESS VISCOMETER FOR INLINE, ONLINE AND ON REACTOR APPLICATIONS
Simple, Rugged, Reliable, No wear part, Low maintenance, Operates in any position, Easy installation
GENERAL TECHNICAL DATA
• Maximum working temperature up to 200 or 300°C
• Maximum working pressure up to 60 bar or 150 bar (500 bar possible at request)
• Maximum viscosity range up to 1000 Pascal.second
• Watertightness of the body IP67
• Material 316L SS, Hastelloy, ...
• Protective coatings Diamolith, PTFE, enamel
• Exproof approval ATEX, FM, JIS
• Sanitary design on request
INDUSTRIES :
Petrol, Petrochemical, Chemical, Food & beverage, Cosmetics, Printing & coating
APPLICATIONS :
Polymerization control, Heavy fuel oil control, Inks control...
PRODUCTS :
Oil, Polymers, Fuels, Bitumen, Resins, Gels, Emulsions, Cheese, molasses, Paints, Inks... |
|
Flow Time Measuring Instrument CUPTIMER 243 T
Objective determination of flow time for viscosity measurements using standardized flow cups. Including temperature bath and adapter rings for the different flow cups. Automatic measuring sequence with optical detection of the efflux stream of sample. Flow times up to 200 s can be read from the LCD with an accuracy of 0.01 s. |
|
| ... products without technical information |
| |
This is the key tool for all professionals in HVAC and industry fields.
AMI 300 can measure, store up to 12,000 values and restore on PC (wireless communication) up to 6 parameters alternately.
Pressure, temperature (RTD, thermocouple, NTC), humidity, air quality (CO/CO2), air velocity and airflow (vanes or hotwire), tachometry.
For visual comfort, AMI has a large colored display and easy browsing is done thanks to its joystick on keypad.
Innovative and evolutive :
- AMI can be equipped with wireless probes (Radio frequency) supplied with a multifunctional key allowing measurement and settings.
- It can be equipped with interchangeable measurement modules which are individually calibrated and are automatically recognized by the instrument thanks to the Smart-plus system.
- These measurement modules are available for pressure, thermocouple temperature (4 channels), climatic conditions (hygrometry, air pressure and temperature) and current/voltage parameters.
- For instance, AMI can be equipped with several pressure measurement modules with different measuring ranges. This new system allows evolution according to measurements that must be carried out…
- Based on the same principle, all probes have the Smart-plus system and are therefore automatically recognized by the instrument. Probes are available with adjusting or calibration certificate.
* exept thermocouple probes
- A large choice of probes allows a step-by-step evolution of the instrument according to your needs : vanes Ø 14 mm, 70 mm and 100 mm, high resistance gooseneck–shaped hotwire, CO/.CO2, multifunction, high temperature hygrometry, RTD probes, thermocouple... |
|
measuring tube inside diameter: 9.7 mm; 18.2 mm; 25 mm; 32 mm; 40 mm; 50 mm ...
alternative forms of connection depending on inside diameter of measuring tube:
tube fittings; cutting ring fittings; flange connection;
flat tube ends; internal screw thread for connecting nipples
alternatively with / without input / output section
initial smallest measurable flow rate dependent on type of vane wheel: in gases from 0.08 m³/h,
in liquids 0.007 m³/h
terminal flow rate dependent on type of vane wheel: in gases 20 m/s; 40 m/s; 80 m/s;120 m/s;
in liquids: 3 m/s; 7.5 m/s; 10 m/s
working temperature range: -20° C... 100 °C; -20 °C... 240 °C and above
maximum working pressure: up to 25 bar above atmospheric
materials: stainless steel; PVDF; aluminium ...
explosion-proof type of protection: Category 1G and 1D Zone 0 and Zone 20; Category 2G and 2D Zone 1 and Zone 21
special designs on request
|
|
| ... products without technical information |
| |
The measuring lenses developed by LINOS feature the highest resolution, excellent contrast, minimum possible distortion and color neutrality. They sharply reproduce images all the way to the very corner edges.
Rogonar-S
Inexpensive lens with good imaging performance. Optimal price/performance ratio.
Rodagon
High-performance lens featuring a highly consistent imaging quality and broad magnification range.
Rodagon-WA
High-performance lens with extended viewing angle (shorter focal length for the same image field possible).
Apo-Rodagon-N
Apochromatically corrected lens designed to meet the highest requirements in an especially broad magnification range.
Apo-Rodagon-D
Apochromatically corrected special lens designed to meet the highest requirements for magnifications from 1:5 to 1:3.
|
|
Hugi MS 600
Measurement and sorting of mass-produced parts: the Hugi MS600 is acompletely automated industrial system for sorting small parts in any batch size.
This guarantees onehundred percent control of diameters and thicknesses thanks to the graduated clearance of a high-precision pair of roller micrometers.
This permits classifications to within thousandths of a millimeter. |
|
Wireless-based high-precision, 8-channel temperature measurement module;
requires WLS-IFC wireless gateway device
- 8 temperature input channels
- Supports thermocouples, RTDs, thermistors, and semiconductor temperature devices
- Superior performance - accuracy exceeds sensor output
- 8 digital I/O bits; user-configurable for alarming
- 802.15.4 wireless protocol
- Range: Up to 150 feet indoors, 2400 feet outdoors
- Included Software: TracerDAQ™, Universal Library, Universal Library for LabVIEW, and InstaCal
- Lifetime Warranty & Harsh Environment Warranty® included |
|
PM100-G - Fiber Optic Power Meter
Simple optical power and loss measurement
PM100-S - Fiber Optic Power Meter
Simple optical power and loss measurement
PM200 - Fiber Optic Power Meter
Link certification and reporting tool
FO600 - FiberMeter Optical Power Meter
FO610 - High Power FiberMeter Optical Power Meter
Ideal for testing and certifying in both Multimode and Single Mode applications
|
|
| Luna Technologies' Optical Backscatter Reflectometer (OBR) delivers unprecedented inspection and diagnostic capabilities for the fiber-optics industry. Luna's state-of-the-art OBR provides isolation of faults and problems well before final test, saving hours in rework and hard dollars in yield loss. |
|
| The OP510 was specifically designed for applications where cost effective solutions for measuring, monitoring and logging of insertion loss or power fluctuations are needed. The OP510 is a small (4"x2"x1.25") desk friendly module designed such that minimal movement and bending of the reference- and test cables is necessary. This results in stable, accurate and repeatable measurements. |
|
| Insertion loss (IL) and return loss (RL) on fiber optical components are measured fast and accurately with the OP930. The return loss is measured with the "no mandrel" method, meaning neither matching gel nor mandrel wraps are required at the far end of the cable. The insertion loss is measured by utilizing the stable transmitter of the return-loss as the source in combination with the precision optical power meter. |
|
| ... products without technical information |
| |
| The B&K Precision Model 889A Synthesized In-Circuit LCR/ESR Meter is a high accuracy test instrument used for measuring inductors, capacitors and resistors with a basic accuracy of 0.2%. Also, with the built-in functions of DC/AC Voltage measurements and Diode/Audible Continuity checks, the Model 889 can not only help engineers and students to understand the characteristic of electronics components but also being an essential tool on any service bench. |
|
Measuring Instrument - LCR Precision Instruments ( LCR200) :
Key Features:
- Measurement Parameters : Z , Ls , Lp , Cs , Cp ,
DCR , ESR , D , Q , and (Theta)
- Test conditions : 100MHz , 120Hz , 1KHz , 10KHz , 100KHz , 200KHz ; 1Vrms , 250mVrms , 50mVrms , 1Vdc(DCR only)
- DMM Functionalities
- Dual LCD Display with LED backlit
- Open / Short calibration
- Remote binning capability
- Auto range / range hold selection |
|
| Agilent LCR and resistance meters are useful in testing components and materials in a variety of research and design applications and in component manufacturing. LCR meters measure impedance (inductance, capacitance, and resistance) at spot frequencies. Resistance meters are optimized for high-resistance or low-resistance measurements. |
|
Product ID: LCR-612
20000 Counts Hand Held LCR Meter Dual Display Auto-Ranging ( LCR-612 )
20000 Counts LCR Meter
Dual Display Auto-Ranging
MODEL: LCR-612
Outstanding Features:
1.Basic accuracy:
0.5% for Resistance
0.7% for Inductance, Capacitance
2.Dual Displays provide quick tested results readouts, with L.C.R. Display values up to 19999 counts and Q.D.R. display values up to 9999 counts
3.Excellent resolutions:
Resistance up to 0.001Ù
Inductance Capacitance up to 0.1uH/0.1pF
4.Provided up to 4 testing parameters:
Ls+(Q,D,Rs), Lp+(Q,D,Rp)
Cs+(Q,D,Rs), Cp+(Q,D,Rp)
5. Auto-Power Off function:
To conserve battery life for longer use.
6.Fuse detection function:
To inform that the fuse is open or damaged.
7.External DC Adapter functions:
Use of a DC adapter can also serve to disable Auto Power Off function.
Dual Display LCR Meter LCR-612 Test Ranges: 120Hz and 1KH
LCR-612 SPECIFICATIONS
LCR-612 Display:
LCR—4 1/2 digits, maximum reading of 19999.
QDR—4 digits, maximum reading of 9999. (Auto range).
Parameter Measurement:
Ls+(Q,D,Rs), Lp+(Q,D,Rp)
Cs+(Q,D,Rs), Cp+(Q,D,Rp)
Overload: "OL" is display.
Test Frequency: 1KHz and 120Hz.
Range Mode: Auto and Manual.
Auto Power Off:
The meter key switch inactive for more than 5 minutes, press power key to resume operation.
Measurement rate: Approx. 1 time per second, nominal.
Power Requirement: (1). Single standard 9-volt battery.
(NEDA 1604, IEC 6F22 006P) ;(2). External DC Adapter 12Vmim to 15Vmax / 50mA.(optional)
Overload Protection: 0.1A/250V fast below fuse.
Dimensions:192mm(H) x 91mm(W) x 52.5mm(D).
Weight: 365g. (including accessories) |
|
| The LCR Meter measure passive components with as little as 0.05 % error. These easy-to-use instruments are quick to setup, adjust and calibrate. The SR715 and SR720 are ideal for applications such as incoming inspection, quality control, automated test, and general benchtop use. |
|
- LCD Display 128 x 64
- File Management ( Flash Memory Card)
- Test Point Range : 64-2048
- Test Voltage : 50-1500VDC (RT-9651 H / CH )
- Insulation Test : 500K-1000MOhm(RT- 9651H/ CH)
- 4-Wire Rsistance Test : Yes
- Components Test : Resistor,Diode,Capacitor(Option)
- Resistor Measurement : 0.1Ohm-20MOhm
- Capacitor Measurement : 100pF-1000uF
- High Quality Relay |
|
1. 320x240 dot-matrix display
2. Test frequency range : 20Hz - 1 MHz
3. Measurement parameter |Z|, Rs, Rp,Xs, Rdc|, |Y|, Gp,
Bp, Ls, Lp, Cs, Cp, D, Q , Theta
4. Basic Accuracy ± 0.1%
5. Measurement Time : 30 mS ( Fast )
6. Bin Function : 8 bins (expandable to 15 bins)
7. Comparator function: Primary / Secondary
8. Memory : 256 instrument setups
9. External Memory interface (Option)
10. Interface : Handler,( Option : GPIB, RS232 ,Printer )
11. Deviation Zero : Open / Short
12. DC Bias (Option) |
|
| ... products without technical information |
| |
|
|