Join Us
Newsletter
|
Exhibit on DirectIndustry
The Virtual Industrial Exhibition
Products
Catalogues
News
Videos
Classifieds
Products
>
Electricity: Switch, Relay, Connector, Cable...
>
voltage selector
Voltage selectors
1
Product |
1
Company
Voltage selector
6.3 - 10 V | SW series
SCHURTER
Series-parallel connections, ...
Catalog search
Schaltbau
Brochure Electrics for rolling stock
Here the first 5 pages from the catalogue "Brochure Electrics for rolling stock", returning results for: voltage selector
P. 3
selector
adjusts the electrical configuration of the train to the detected
voltage
, and the traction contactors are suitable both for AC and DC operation. With our control devices ? from ID card reader to master controller ? the driver will drive the train safely to its destination
P. 16
in cross-border service and are operated with different high-
voltage
power sources. Required control signals are generated by the corresponding
voltage
selector
ZH1114. Load-free adjustment of electrical configurations to different networks, e.g. various train line
voltages
in accordance with UIC 550
P. 5
Quality you can count on Page 5 I Electrics for rolling stock Products for traffic engineering :: Schaltbau transportation system components High-
voltage
switchgear and inverters High-
voltage
switchgear is designed for the safe handling of UIC
voltages
. Schaltbau offers two kinds of static
P. 14
Features Specifications Electrics for rolling stock I Page 14 H2/H3 switchgear cabinets H2/H3 equipment cabinet with disconnecting and earthing device and high-
voltage
switchgear The high-
voltage
switchgear of passenger coaches is integrated in these cabinets. The built-in disconnecting
P. 18
Features Specifications Electrics for rolling stock I Page 18 Series ZH842 H Solid-state HV
signalling
relay The ZH842 H Series solid-state high-
voltage
sensor signals high
voltage
applied to the train line. The device supplies electrical loads, which for the conservation of battery power
BSI Computer
FieldGo N9 Portable Workstation
Here the first 5 pages from the catalogue "FieldGo N9 Portable Workstation", returning results for: voltage selector
P. 15
communication port power off switch universal serial bus connectors minidin ps 2 keyboard connector minidin ps 2 mouse connector input
voltage
selector
switch 11
P. 7
the workstation b important safety instructions b before using your workstation read the following safety instruc tions to make sure you use the workstation safely effectively 9830 always check your power supply input
voltage
selector
switch before connecting the ac power cord to the workstation it s two position
P. 17
fieldgo portable workstation user s guide chapter 3 starting your system before you turn your system observing the following steps will prevent any startup problems 1 make sure the input
voltage
selector
switch the power supply is set correctly to either 115v 230v depending your local outlet
P. 12
minidin 6pin connectors the cable ends first the keyboard connector the touchpad connector is daisychained to the keyboard connector located the end the cable n fig 2 connecting the keyboard touchpad 9830 check the
voltage
switch below the power supply fan the left side the system to make sure it s set to
P. 40
fieldgo portable workstation user s guide color gamut response time luminance signal system supply
voltage
backlight power consumption 42 typ center to ntsc 15ms typ white to black 200cd m2 typ analog rgb signals synchronous signals hsync vsync dclk 12v 12v logic lcd driving backlight edge light
Monolithic Power Systems
MP20046 Fast Transient Response, 2A Low Dropout Voltage Regulator
Here the first 5 pages from the catalogue "MP20046 Fast Transient Response, 2A Low Dropout Voltage Regulator", returning results for: voltage selector
P. 2
20046dns 33v soic8e m20046s other output
voltage
versions between 15v 33v contact factory availability ordering guide mp20046d lfz output
voltage
see output
voltage
selector
guide table package type q qfn10 3mm x 3mm n soic8e operating temperature range d extended temperature range 40oc to 85oc rohs
P. 11
mp20046 fast transient response 2a low dropout
voltage
regulator operation the mp20046 is low dropout linear regulator supplying up to 2a current it is intended use devices that require very low dropout
voltage
low quiescent low noise high psrr such as wireless lan battery powered equipment
P. 4
mp20046 fast transient response 2a low dropout
voltage
regulator electrical characteristics vin vout b typ b 1v 27v iout 1ma ven 0v cout 47uf t b j b 40 c to 125 c unless otherwise noted typical values are ta 25 c parameter symbol condition min typ max units output
voltage
15v b vout b 27v vin 55v
P. 5
mp20046 fast transient response 2a low dropout
voltage
regulator pin functions soic8e pin qfn10 3mmx3mm pin name description 1 2 1 2 3 vout regulated output
voltage
3 4 sense output sense 4 5 gnd exposed pad ground connect exposed pad to gnd plane optimal thermal performance 5 6 en negative
P. 6
mp20046 fast transient response 2a low dropout
voltage
regulator typical performance characteristics vin 38v vout 33v cin cout 47 jf ta 25oc unless otherwise noted quiescent current vs temperature quiescent current vs input
voltage
dropout
voltage
vs temperature b d b o 90 80 70 60 50 40 30 20 10 0
Augier
TED TRANSFORMER
Here the first 5 pages from the catalogue "TED TRANSFORMER", returning results for: voltage selector
P. 17
17 TED MTT (16, 25 kVA) TED MTT (32, 50 kVA) 1 - LV
output
2 - LV
protection
(optional) 3 - MV
Phase
selector
4 - MV
adjusting
switch 5 - MV
three-
pole unpluggable terminals 6 - MV
fuses
Power rating (kVA) 16 25 32 50 Power output (kVA) 12.8 20 25.6 40 Iron losses (W) 100 130 155 160
P. 15
15 1- MV
fuses
and phase -
selector
2- MV
three-pole
terminal 3- MV
inlet
4- MV
outlet
5- Rating plate 6- Earthing terminal M 10 x 20 7- LV
protection
8- LV
output
TED MTT TECHNICAL DATA - 2, 3, 5, 10 kVA Power rating (kVA) 2 3 5 10 Power output (kVA) 1.6 2.4 4 8 Iron losses (W) 30 45 60
P. 14
,5 mm, maximum allowance included. b- «Lead-through» connection in transformer. TAP CHANGER FOR
VOLTAGE
ADJUSTMENT No
voltage
adjustment provided. M.V. PROTECTION By means of two HRC fuses, rupturing capacity 10 kA. PHASE
SELECTOR
Medium
Voltage
fuses allows even load distribution among
P. 5
transformers from 16 kVA and to the three- phase transformers of all power ratings. * A phase
selector
allows an even load distribution among the 3 phases of the supply network. Plug-in, MV
network
epoxy resin accessories are also available. They enable cable isolation to be carried out, among
P. 16
: 44.5 mm, maximum allowance included. On request : elbow bent terminals. b- «Lead-through» connection in transformer. TAP CHANGER FOR
VOLTAGE
ADJUSTMENT Adjustment by strips off
voltage
, taps + 5, + 7,5 % (3) M.V. PROTECTION By means of two HRC fuses, rupturing capacity 15 kA. PHASE
SELECTOR
Siemens AG
SITOP Power supply
Here the first 5 pages from the catalogue "SITOP Power supply", returning results for: voltage selector
P. 139
SITOP 24 V 1-phase, 2-phase, 3-phase Siemens KT 10.1 · 2009 15/11 ¡Dimension drawings Dimension drawing 1 with dimensions in mm For devices with order number: 6EP1 334-1SH01 125
VOLTAGE
SELECTOR
power 10 SITOP 200 G_KT01_DE_00108 36 135 2) Dimension drawing 2 with dimensions in mm
P. 34
-230/230-500 V AC Set by means of
selector
switch on device 120/230 V AC Set by means of
selector
switch on device 120/230 V AC Set by means of
selector
switch on device
Voltage
range 85 ... 264 V/176 ... 500 V 85 ... 132 V/170 ... 264 V 85 ... 132 V/170 ... 264 V Overvoltage resistance 1300 Vpeak, 1
P. 40
power up to 45 °C. Dimension drawing Page 15/9, Dimension drawing 2 Page 15/10, Dimension drawing 1 Page 15/10, Dimension drawing 1 Input 1-phase and 2-phase AC 1-phase AC 1-phase AC Rated
voltage
value Vin rated 120-230/230-500 V AC Set by means of
selector
switch on device 120/230 V AC Set
P. 50
of
selector
switch on device 120-230/230-500 V 2 AC Set by means of
selector
switch on device 400-480 V 3 AC Wide-range input
Voltage
range 85 ... 264/176 ... 550 V 85 ... 264/176 ... 550 V 340 ... 550 V (320 ... 340 V for max. 1 min) Overvoltage resistance 1300 Vpeak, 1.3 ms 1300 Vpeak, 1.3 ms
P. 22
drawing 2 Page 15/5, Dimension drawing 1 Page 15/5, Dimension drawing 2 Input 1-phase AC 1-phase AC Rated
voltage
value Vin rated 120/230 V AC set by means of
selector
switch 100-240 V AC Wide-range input 120/230 V AC Automatic range selection
Voltage
range 85 ... 132 V/170 ... 264 V 85 ... 264
recherche-kwref www di En 2012-05-22-28