Multi channels weight transmitter type G4-RM
The G4-RM transmitter is a new generation of multiple weighing transmitter / indicator.
It is based around a main frame with:
One LCD screen two lines 16 characters
A 4 keypad pannel
One CPU unit with RS232; RS485 serial communication in Modbus RTU, an one Ethernet communication interface in Modbus TCP for easy connections to PLC & supervision.
The CPU card is also equipped with a USB connector for Back Up and restore or for a printer / key board connection.
The G4-RM can also handle up to 6 weighing channels through the WF-IN1 and WF-IN2 weighing cards with an internal 24 bits A/D converter and can reach a speed reading of 300 readings / sec or up to 1200 reading / sec with the weighing card HSWF-IN1 or 2.
Each weighing channel is equipped with 4 digital Inputs and 2 digital Outputs.
All set up can be done via the 4 push buttons keys panel or a dedicated software running on PC
All set up can be saved and restore on the internal memory or on an external USB memory stick.
Field buses: Profibus DP or Device Net can be installed on the CPU card as an option.
|
|
|
The transmitters 1045 and indicating 1050 are particularly adapted to the most current applications of weighing with an excellent quality ratio/Prix. Out of standard: Galvanically isolated analogical exit, port serial RS485 MODBUS RTU, left RS232/RS422 codes ASCII, Fonctions Tares Car, GROSS/NET, Fonction Memo peak, detection of stability of the weighing. In option, Exit drunk of ground PROFIBUS DP or DEVICE NET. Assembly rail DIN for 1045 and table for 1050 with food 24 Vcc.
|
|
The LCIC-WIM allows to connect most load cells and scales to a PC via the popular USB or RS232/485 ports.
The LCIC-WIM was designed to fit all real-time weighing and force measurement applications, like:Checkweigher, Weighing In Motion (trucks and rails),Batching and filling systems, Testing machines etc. this product helps our customers to easily design their controllers saving them engineering time and money.
|
|
|
Weighing amplifiers and transmitters are available, for example, for networking platforms in control and automation systems. A choice of versions is supplied for the diverse hazardous area zone classifications and approvals.
|
|
AST 3P / AST 3IS
Analogue output ±10 VDC, 0-20 or 4-20 mA. Digital output RS-485, MODBUS and via GATE 3 fieldbus communication.
WST 3
Analogue output ± 10 VDC, 0–20 or 4–20 mA. Serial communications: RS-485, MODBUS RTU protocol. Fieldbus interface: Profibus DP.
|
|
|
Weighing and batching electronics CE; CE-M and ATEX approved. Digital / Analogic Trasmitters. PC/PLC connection by the main communication protocols on the market. Weighing systems with more scales. Digital load limiting devices. Weighing in hazardous area.
|
|
For all activities, our indicator range give you many possibilities.
Laid on table, with column kit or wall mounting kit, our indicators are easy to use and very reliable.
The whole range is available either in stainless steel or in resin and can be connected to all Precia Molen load receptors.
I 100 indicator
Indicators range I 200
Indicators range I 200 Ex
Indicators range I 300
I 400: Programmable weighing indicator
High performance weighing system with industrial field buses interface
|
|
Typical applications may be: - Hopper weighing and batching systems - Road and rail weighing platforms - Conveyour scales, weigh feeders and blending sysMAIN
FEATURES :
- Power supply up to 6 load cells
- Optoisolated RS232 and RS485 serial ports
- Optoisolated 4 - 20 mA analog output
- Failure alarm hardware output
- High/low alarm hardware outputs
- Tare set/reset inputs
- Optoisolation of all digital input/output
- Stand-stil signal and peak value measurement
- Periodic selfcorrection of thermal drifts
- Optional local Key-board/display
tems - Silo level measurement and alarms
|
|
TRANSMITTERS
AST 3P / AST 3IS
Analogue output ±10 VDC, 0-20 or 4-20 mA. Digital output RS-485, MODBUS and via GATE 3 fieldbus communication.
WST 3
Analogue output ± 10 VDC, 0–20 or 4–20 mA. Serial communications: RS-485, MODBUS RTU protocol. Fieldbus interface: Profibus DP.
|
|
T010E is a weight transmitter amplifier that uses a modern microcontroller. Four push buttons and one display that shows the guide messages, help the operator in the configuration and weight calibration.
T010E is an instrument with high modularity. The base configuration is equipped with a display to show the weight data and two relays thresholds can be programmed as required. The options foresees one serial line available in RS232 or in RS485 mode, a radio transmission for remote data weight transfer (with R010E serial repeater), an analog output 0-10 V or an analog output 4-20 mA.
In the overload control modality (option) the instrument can be associated to category 1 as a security device (UNI EN 954-1 12-98 norm). The smaller dimensions, the best ratio quality price, make the T010E the best solution for many applications.
|
|
Industrial bus: Profibus DP
Accuracy class: 0,01 %
Insignal range: -4 - +4 mV/V
Loadcell Excitation: 5 VDC
Lastcellsström: Max 100 mA
Conversion rate: 3.25 - 30 conversions/s
Counts: -25 000 - +25 000
Internal counts: -400 000 - +400 000
Power supply: 24 VDC
Cabinet: Shielded metal cabinet
Mounting: DIN-rail (TS35)
|
|
|
|
|
|
TRANSMITTERS
JA - FIELD RANGABLE ANALOG TRANSMITTER
APPLICATIONS
-Strain Gage Measurements
- Load Cells
- Force Transducers
- Torque Transducers
- Pressure Transducer
- Transducer Interface To PLC/DCS
- Process Control
- Weighing Systems
- Level Monitoring and Control
- Intrinsically Safe Applications
- Cost Effective OEM/VAR Solutions
FEATURES
- High Performance Measurements-Grade Power Supply And Precision Amplifier
- Range Of Selectable Output Formats For Voltage Or Current
- Input, Output, Excitation And Zero Offset Parameters Are Field Configurable
- Compatible With Single Or Multiple "Summed" Transducers
- Preload Offsets Adjustable Up To 100% of Span Range
- Linear Optical Isolation Of The Input, Output And Power Supply Eliminates
- Loop Potential, Provides Common Mode Rejection And Reduces Noise Pickup
- Remote Sensing Is Selectable And Maintains Constant Voltage At the Transducer(s)
- DIN Rail Or Panel Mount Using Industry Standard Plug-N-Play 11-Pin Socket
- No Interaction Between Zero And Span
- Designed For Use In "Electrically Noisy" Industrial Environments
- Functional Test/System Calibration Pushbutton
- Easy Setup And Calibration
- Multiple LED's Monitor Input And Output Signal Levels
- Powers Up To (4) 350 Ohm And Up To (8) 700 Ohm Transducers
- Compact Case Dimensions Of Only 2.75" High X 2.38" Wide X 1.75" Deep
- The JB Series is A "Summing Transmitter" Version Integrated With A Four Channel
- Summing Module In A NEMA 4/4X Enclosure
- NEMA 4/4X And Explosion-Proof Housings Are Available
- The JD Series Is A Low Cost "Fixed Range" Alternative To The "Rangeable" JA Series
- One Year Warranty
|
|
CAN-DY (Field Bus load cell Transmitter)
> Digital transmitter for 1 to 4 load cells of 350 W
> IP 66 plastic box
> 2 operating modes :
- RS 485 output modbus protocole
- CAN network output - CAN OPEN protocole
> With CAN network configuration, CHAINDY option is available
> Possibility to connect on the same Bus 13 CANDY transmitters
(Modbus, Profibus, Device Net, Ethernet)
|
|
| ... products without technical information |
| |
|
|