Fluid analysis sensor: viscosity, density, dielectric constant, temperature
Viscomaster™ series
Aquametro AG
Viscosity and density sensors
Technical data
Viscosity calibrated ranges
- 0.5 to 100 cP (Viscomaster) 0 to 50 cP (Dynamic)
Viscosity accuracy
- ±1 % span (±0.2 cP in 0 to 10 cP range)
Viscosity repeatability
- ±0.5 % of reading
Temperature range
- Process -50 to +200 °C (-60 to +392 °F)
- Ambient -40 to +85 °C (-40 to +185 °F)
Pressure range (Lloyd's approval valid to 70 bar / 1030 psi maximum.)
- As defined by process connection
ViscoMaster Density
Density calibrated range
- 0.6 to 1.25 g/cc (38 to 78 lb/ft3)
Density accuracy
- ±0.001 g/cc (±0.0624 lb/ft3)
Density repeatablity
- ±0.0001 g/cc (±0.0062 lb/ft3)
Technical data
Viscosity calibrated ranges
- 0.5 to 100 cP (Viscomaster) 0 to 50 cP (Dynamic)
Viscosity accuracy
- ±1 % span (±0.2 cP in 0 to 10 cP range)
Viscosity repeatability
- ±0.5 % of reading
Temperature range
- Process -50 to +200 °C (-60 to +392 °F)
- Ambient -40 to +85 °C (-40 to +185 °F)
Pressure range (Lloyd's approval valid to 70 bar / 1030 psi maximum.)
- As defined by process connection
ViscoMaster Density
Density calibrated range
- 0.6 to 1.25 g/cc (38 to 78 lb/ft3)
Density accuracy
- ±0.001 g/cc (±0.0624 lb/ft3)
Density repeatablity
- ±0.0001 g/cc (±0.0062 lb/ft3)
-
zoom