- gas intake
- separator removes condensed water from the incoming gases
- shuttle valve alternates drying/regenerating chambers in a push-pull cycle
- desiccating chamber with replaceable cartridges
- main flow non-return cocks regulate the flow of gas that is to be dried Gases
- particle professional filter
- pressure maintaining valve
- regeneration flow non-return valves that regulate the flow of gas that is -required for regeneration
- pressure reduction valve lowers the pressure to the regeneration and control pressure
- flow controller valve restricts the regeneration volume
- pressure compensation valve equalises pressure amongst the two chambers before a switch over
- cut-off valve closes at equal pressure and during idle running
- condensate drain
- activated carbon filtering for air purification according to DIN EN 12021, EN 12021 and other international standards