Bergoz Instrumentation

High-accuracy current transformer
Tuned-CT Bergoz Instrumentation

Tuned-CT
Narrowband Current Transformer

For beam loss monitoring in low energy hadron accelerators

Measures current difference between two monitoring points with 0.05% resolution, e.g. measures 5% loss with 1% resolution

To keep machine activation low enough for hands-on maintenance, personnel safety and environmental protection

To protect machine parts from beam radiation damage

To achieve efficient beam transport

To measure beam loss along an accelerating structure, when no secondary particles can exit the vacuum chamber, the only option is to measure the beam current at regular intervals. Non-interceptive current transformers can be used for this purpose.
Wideband transformers cannot measure the beam current accurately because their response is dependant on the frequency spectrum, thus dependant on the bunch width.
  • zoom



standListOtherProduct www di En 2012-05-20-20