Description:
Via a hole in the pipe (plastic deformation with the measuring professional connector serv-Clip® Type 2), the sensor is placed directly into the oil circuit. The measuring system is based on the calorimetric principle, measuring flow rate speed in Meter/Second. Inexpensive and rapid Mounting. Durable and compact design.
It can be combined with measuring connector serv-Clip® Type 2 ( for mounting on non-pressurized pipes ).
Installation ONLY 3 Minutes, NO NEED TO CUT PIPES www.servclip.com
You can measure in several points with ONE sensor but for each tube you need the measuring connection serv-Clip.
Technical data
- Measuring range 0,05 …8 m/s (HYDRAULIC OIL)
- Range of application 0,50 …6 m/s
- Output signal 4 ... 20 mA
- Psu 24 V DC +/-10%; 150 mA
- Electrical connection M12-universal connector
- Range setting by micro-switches 6 LED
- For pipe diameters Ø 12 mm and larger
- Calibration service available upon request (*)
(*) You have to indicate us the ID of your tubes and the wished min/max liter/minute. You get a calibration table for your own technical case.