There are a number of measuring methods ("autarkon"-differential pressure measurement with all common differential pressure devices,
"trikon"-vortex meter) available for steam flow rate and steam energy measurements.
The right selection depends mainly on the technical and economic demands of the respective requirements. Only with this data knowledge is it possible to select the most suitable measuring system to achieve optimum alignment to existing operating conditions.
The product range includes meters for internal balancing measurements as well as high-precision steam calculation measurements with plausibility control during operation. Bi-directional steam measurements and combined steam-condensate-energy measurements are also contained in our product range.
Performance data: Measurement of saturated / superheated steam with pressure and temp. compensation
Pressure range: 1 - 100 bar (abs.)
Temperature range: 100 - 550 °C
Measuring range: up to 30 : 1 relating to the mass flow
Accuracy: up to < ± 0.5% relating to the current value