Definition: Electric furnace for glass work.
Construction: Robustly built in folded sheet steel. Bell furnace has opening assisted by hydraulic cylinders.
Insulation: Multilayer insulation. Interior in ceramic fibre and refractory bricks.
Aeration: Exhaust vent on top.
Heating: Spiral wound resistors on the roof of the furnace.
Electricity: Voltage 230 VAC, up to 10 kW and voltage 3x400 VAC from 10 kW, 50 Hz.
Regulation: Axron Swiss PID temperature controller.
Documentation: CE marking and operating instructions in English.