Microphone conditioning amplifier
2 channel | NEXUS™ series
Bruel and Kjaer
The NEXUS™ concept is based on a single mainframe, a number of input/output channels, and different filter options. This makes it highly flexible, as you can configure your conditioning amplifier to your needs. You can have acoustic and vibration inputs in the same mainframe with one, two, three or four independent input channels.
NEXUS can be reconfigured if your requirements change. If, for example, you have a 1-channel Charge Conditioning Amplifier, it can be updated to a 2-channel Charge/2-channel Microphone Conditioning Amplifier. Hardware/software updates, for example, auxiliary modules with A-, B-, C- and D-weighting filters or integration, make the concept even more flexible.
Microprocessors are used for control, display and interfacing purposes, but the signal is maintained analogue to obtain optimum signal/noise ratio and the lowest possible distortion. NEXUS supports transducers with TEDS according to IEEE 1451.4.
Portability and Rack Mounting
NEXUS Conditioning Amplifiers are equally suited for laboratory and field use. They are compact and self-contained with an optional rechargeable battery. They are lightweight too, weighing around 3 kg (6.6 lb.), including battery. Rack-mounting fittings are available for in-car testing purposes as well as for stationary use. The portable 19" rack KQ-0158 can contain up to 9 NEXUS units. Up to 16 NEXUS channels and a DAT recorder can be mounted in a compact unit (UA-1409) which is particularly suitable for automotive use. UA-1409 has fittings for a carrying strap.
NEXUS can be reconfigured if your requirements change. If, for example, you have a 1-channel Charge Conditioning Amplifier, it can be updated to a 2-channel Charge/2-channel Microphone Conditioning Amplifier. Hardware/software updates, for example, auxiliary modules with A-, B-, C- and D-weighting filters or integration, make the concept even more flexible.
Microprocessors are used for control, display and interfacing purposes, but the signal is maintained analogue to obtain optimum signal/noise ratio and the lowest possible distortion. NEXUS supports transducers with TEDS according to IEEE 1451.4.
Portability and Rack Mounting
NEXUS Conditioning Amplifiers are equally suited for laboratory and field use. They are compact and self-contained with an optional rechargeable battery. They are lightweight too, weighing around 3 kg (6.6 lb.), including battery. Rack-mounting fittings are available for in-car testing purposes as well as for stationary use. The portable 19" rack KQ-0158 can contain up to 9 NEXUS units. Up to 16 NEXUS channels and a DAT recorder can be mounted in a compact unit (UA-1409) which is particularly suitable for automotive use. UA-1409 has fittings for a carrying strap.
-
zoom