Loading dock lift table
BUTT
Combination Scissor-Type-Table-Lift/Sliding-Adjustable Ramp
This combination can be used both Scissor-Type-Table-Lift and Sliding-Adjustable ramp and is so a space-saving option to the seperate installation.
Its advantages in detail:
Particularly safe:
Allround safety contact rail at the top frame to protect against crushing
Dead man controls for raising and lowering
Maintenance supports designed for max. load
Pipe break security in the event of a hose rupture
The safety specifications meet the European machine directive, EN 1570 and UVV/VBG 14
Protection type: IP 54
Control voltage: 24 volt DC for all functions incl. solenoid valve
Dimensioned for a 50 % static overload and tested accordingly
Particularly economical:
Complete assembly kit
Ready for connection using CEE plug
Version ready for installation
Safety instructions:
At a drop height of 1 m or more (ramp height), the ramp must be secured in the area of the lifting table. This can be accomplished with the aid of a gantry scaffolding (portal height = ramp height + 1100 mm).
If personnel is to ride along on the lifting table, ensure that the platform is provided with means for holding on. This can be accomplished with the following: Plug-in railing, Fixed railing, Gantry scaffolding, Control column.
If the control is to take place from the platform, an underrun protection is required at the accessible sides of the lifting table. This also applies when the bottom area of the lifting table is not directly visible from the control column.
When fork lift trucks drive on the platform while in extended position, a roll-off protection is required on the free sides. This also applies to other rolling loads.
This combination can be used both Scissor-Type-Table-Lift and Sliding-Adjustable ramp and is so a space-saving option to the seperate installation.
Its advantages in detail:
Particularly safe:
Allround safety contact rail at the top frame to protect against crushing
Dead man controls for raising and lowering
Maintenance supports designed for max. load
Pipe break security in the event of a hose rupture
The safety specifications meet the European machine directive, EN 1570 and UVV/VBG 14
Protection type: IP 54
Control voltage: 24 volt DC for all functions incl. solenoid valve
Dimensioned for a 50 % static overload and tested accordingly
Particularly economical:
Complete assembly kit
Ready for connection using CEE plug
Version ready for installation
Safety instructions:
At a drop height of 1 m or more (ramp height), the ramp must be secured in the area of the lifting table. This can be accomplished with the aid of a gantry scaffolding (portal height = ramp height + 1100 mm).
If personnel is to ride along on the lifting table, ensure that the platform is provided with means for holding on. This can be accomplished with the following: Plug-in railing, Fixed railing, Gantry scaffolding, Control column.
If the control is to take place from the platform, an underrun protection is required at the accessible sides of the lifting table. This also applies when the bottom area of the lifting table is not directly visible from the control column.
When fork lift trucks drive on the platform while in extended position, a roll-off protection is required on the free sides. This also applies to other rolling loads.
-