Maximum operating temperatures of 1700°C or 1800°C
1700°C chamber capacities of 3 or 10 litres
1800°C chamber capacities of 4 or 8 litres
Powerful MoSi2 elements located on both sides of the chamber ensure good thermal uniformity
Thick diameter MoSi2 elements can withstand the stress of everyday operation and provide good longevity
Low thermal mass insulation and good element design is used to ensure energy efficiency and rapid heating
Manually operated vertical counter-balanced door keeps hot door insulation away from operator
Postive break door safety switch isolates chamber from power supply, when the door is opened
Double skinned construction allows fanned air flow to cool the outer case, to conform to EN61010 safety standard
Eight segment programmer is fitted as standard, with options for other types
Adjustable overtemperature protection is fitted as standard