Dry type distribution transformer (amorphous metal)
10 kV, 30 - 2 500 kVA | SCBH15
Chint Electric Co.,Ltd.
SCBH15 Amorphous Alloy Dry-type Transformer
Application: applicable for all places where common dry-type transformers are used, such as high-rise buildings, commercial centers, airports, oil platforms, subways, tunnels, airports, railway stations, industrial and mining enterprises and power plants. It is especially suitable for places which are flammable and explosive.
Standards: IEC 60076-11
Parameters:
Rated capacity: 30-2500kVA
HV rated voltage: 10kV
Features:
SCBH15 Amorphous Alloy Dry-type Transformer.
High safety and reliability, non-pollution, can directly run in the load center.
High mechanical strength, high resistance to short-circuit, low partial discharge, high thermal stability and long life.
Low no-load loss, high efficiency and low noise.
Good thermal performance, high running capability. It can increase the capacity to run during forced air cooling.
Good moisture performance, fire-retardant, explosion prevention and maintenance-free.
Small size, light weight.
Technical Parameter:
Model: SCBH15-3 to SCBH15-2500
Voltage Combination:
- HV (kV): 6 to 11
- Tap Range: ±5 Or ±2 x 2.5
- LV (kV): Dyn11
No-load Loss (W): 70 to 1200
Load Loss (W):
- 100℃ (B): 670 to 17760
- 125℃ (F): 710 to 18890
- 145℃ (H): 760 to 20290
No-load Current (%): 1.6 to 0.5
Short circuit impedance (%): 4 to 8
Note: The values of load loss (W) listed in the sheet 9 are under particular temperature levels corresponding with specific insulated heat-resistant levels listed in the parenthesizes.
Application: applicable for all places where common dry-type transformers are used, such as high-rise buildings, commercial centers, airports, oil platforms, subways, tunnels, airports, railway stations, industrial and mining enterprises and power plants. It is especially suitable for places which are flammable and explosive.
Standards: IEC 60076-11
Parameters:
Rated capacity: 30-2500kVA
HV rated voltage: 10kV
Features:
SCBH15 Amorphous Alloy Dry-type Transformer.
High safety and reliability, non-pollution, can directly run in the load center.
High mechanical strength, high resistance to short-circuit, low partial discharge, high thermal stability and long life.
Low no-load loss, high efficiency and low noise.
Good thermal performance, high running capability. It can increase the capacity to run during forced air cooling.
Good moisture performance, fire-retardant, explosion prevention and maintenance-free.
Small size, light weight.
Technical Parameter:
Model: SCBH15-3 to SCBH15-2500
Voltage Combination:
- HV (kV): 6 to 11
- Tap Range: ±5 Or ±2 x 2.5
- LV (kV): Dyn11
No-load Loss (W): 70 to 1200
Load Loss (W):
- 100℃ (B): 670 to 17760
- 125℃ (F): 710 to 18890
- 145℃ (H): 760 to 20290
No-load Current (%): 1.6 to 0.5
Short circuit impedance (%): 4 to 8
Note: The values of load loss (W) listed in the sheet 9 are under particular temperature levels corresponding with specific insulated heat-resistant levels listed in the parenthesizes.
-